Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (recast) (Text with EEA relevance)
Print Options
PrintThe Whole
Directive
PrintThe Whole
Annex
PrintThis
Part
only
Changes over time for: PART II
Llinell Amser Newidiadau
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Status:
EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.
PART IIU.K.SPECIFIC REQUIREMENTSVOLUME CONVERSION DEVICES
A volume conversion device constitutes a sub-assembly when it is together with a measuring instrument with which it is compatible.
For a volume conversion device, the essential requirements for the gas meter shall apply, if applicable. In addition, the following requirements shall apply:
7. Base conditions for converted quantities U.K.
The manufacturer shall specify the base conditions for converted quantities.
8. MPE U.K.
0,5 % at ambient temperature 20 °C ± 3 °C, ambient humidity 60 % ± 15 %, nominal values for power supply;
0,7 % for temperature conversion devices at rated operating conditions;
1 % for other conversion devices at rated operating conditions.
Note:U.K.
The error of the gas meter is not taken into account.U.K.
The volume conversion device shall not exploit the MPEs or systematically favour any party.U.K.
9. Suitability U.K.
9.1.An electronic conversion device shall be capable of detecting when it is operating outside the operating range(s) stated by the manufacturer for parameters that are relevant for measurement accuracy. In such a case, the conversion device must stop integrating the converted quantity, and may totalise separately the converted quantity for the time it is operating outside the operating range(s).U.K.
9.2.An electronic conversion device shall be capable to display all relevant data for the measurement without additional equipment.U.K.