Regulation (EC) No 999/2001 of the European Parliament and of the CouncilShow full title

Regulation (EC) No 999/2001 of the European Parliament and of the Council of 22 May 2001 laying down rules for the prevention, control and eradication of certain transmissible spongiform encephalopathies

[F14. Rapid tests U.K.

For the purposes of carrying out the rapid tests in accordance with Articles 5(3) and 6(1), only the following methods shall be used as rapid tests for the monitoring of BSE in bovine animals:

  • the immunoblotting test based on a Western blotting procedure for the detection of the Proteinase K-resistant fragment PrPRes (Prionics-Check Western test),

  • the sandwich immunoassay for PrPRes detection (short assay protocol) carried out following denaturation and concentration steps (Bio-Rad TeSeE SAP rapid test),

  • the microplate-based immunoassay (ELISA) which detects Proteinase K-resistant PrPRes with monoclonal antibodies (Prionics-Check LIA test),

  • the immunoassay using a chemical polymer for selective PrPSc capture and a monoclonal detection antibody directed against conserved regions of the PrP molecule (IDEXX HerdChek BSE Antigen Test Kit, EIA & HerdChek BSE-Scrapie Antigen (IDEXX Laboratories)),

  • the lateral-flow immunoassay using two different monoclonal antibodies to detect Proteinase K-resistant PrP fractions (Prionics Check PrioSTRIP),

  • the two-sided immunoassay using two different monoclonal antibodies directed against two epitopes presented in a highly unfolded state of bovine PrPSc (Roboscreen Beta Prion BSE EIA Test Kit).

For the purposes of carrying out the rapid tests in accordance with Articles 5(3) and 6(1), only the following methods shall be used as rapid tests for the monitoring of TSE in ovine and caprine animals:

  • the sandwich immunoassay for PrPRes detection (short assay protocol) carried out following denaturation and concentration steps (Bio-Rad TeSeE SAP rapid test),

  • the sandwich immunoassay for PrPRes detection with the TeSeE Sheep/Goat Detection kit carried out following denaturation and concentration steps with the TeSeE Sheep/Goat Purification kit (Bio-Rad TeSeE Sheep/Goat rapid test),

  • the immunoassay using a chemical polymer for selective PrPSc capture and a monoclonal detection antibody directed against conserved regions of the PrP molecule (HerdChek BSE-Scrapie Antigen (IDEXX Laboratories)),

  • [F2. . . . .]

In all rapid tests, sample tissue on which the test must be applied must comply with the manufacturer's instructions for use.

Producers of rapid tests must have a quality assurance system in place that has been approved by the EU reference laboratory and ensures that the test performance does not change. Producers must provide the EU reference laboratory with the test protocols.

Changes to rapid tests and to test protocols may only be made after prior notification to the EU reference laboratory and provided that the EU reference laboratory finds that the change does not alter the sensitivity, specificity or reliability of the rapid test. That finding shall be communicated to the Commission and to the national reference laboratories.]