Print Options
PrintThe Whole
Rule
PrintThe Whole
Schedule
PrintThis
Section
only
Changes over time for: Paragraph 6
Timeline of Changes
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Status:
Point in time view as at 07/08/2009.
Changes to legislation:
There are currently no known outstanding effects for the The Manufacture and Storage of Explosives Regulations (Northern Ireland) 2006, Paragraph 6.
Changes to Legislation
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
This section has no associated Explanatory Memorandum
6. The distance between a store and—N.I.
(a)any minor road or railway line shall be half; and
(b)any footpath, footway, lightly-used road or waterway shall be one-third,
the distance shown in column 2 of the Table corresponding to the quantity of explosives shown in column 1 of the Table.
TABLE 1
HAZARD TYPE 1 EXPLOSIVE IN A BRICK-BUILT MOUNDED STORE
1 | 2 | 3 | 4 | 5 | 6 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
---|
0.1–25 | 101 | — | 101 | — | — |
25–50 | 107 | — | 107 | — | — |
50–75 | 112 | — | 112 | — | — |
75–100 | 118 | — | 118 | — | — |
100–150 | 128 | 142 | 128 | 257 | 81 |
150–200 | 139 | 156 | 139 | 278 | 96 |
200–300 | 161 | 180 | 161 | 322 | 128 |
300–400 | 183 | — | 183 | — | — |
400–450 | 193 | — | 193 | — | — |
450–500 | 204 | — | 204 | — | — |
500–600 | 204 | — | 216 | — | — |
600–700 | 204 | 231 | 238 | 408 | 206 |
700–800 | 204 | 238 | 260 | 408 | 206 |
800–900 | 204 | 245 | 280 | 408 | 206 |
900–1000 | 204 | 250 | 300 | 408 | 206 |
1000–1100 | 204 | 255 | 319 | 408 | 206 |
1100–1200 | 204 | 259 | 337 | 408 | 206 |
1200–1300 | 204 | 263 | 354 | 408 | 206 |
1300–1400 | 204 | 266 | 370 | 408 | 206 |
1400–1500 | 204 | 269 | 386 | 408 | 206 |
1500–1600 | 204 | 272 | 402 | 408 | 206 |
1600–1700 | 208 | 274 | 416 | 416 | 214 |
1700–1800 | 215 | 277 | 431 | 431 | 229 |
1800–1900 | 222 | 279 | 444 | 444 | 244 |
1900–2000 | 229 | 281 | 458 | 458 | 259 |
TABLE 2
HAZARD TYPE 1 EXPLOSIVE IN A BRICK-BUILT UNMOUNDED STORE
1 | 2 | 3 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | Vulnerable building distance (metres) |
---|
0.1–25 | 141 | 141 |
25–50 | 160 | 160 |
50–75 | 180 | 180 |
75–100 | 199 | 199 |
100–150 | 230 | 230 |
150–200 | 256 | 256 |
200–300 | 293 | 293 |
300–400 | 320 | 320 |
400–450 | 331 | 331 |
450–500 | 340 | 340 |
500–600 | 355 | 355 |
600–700 | 367 | 367 |
700–800 | 377 | 377 |
800–900 | 385 | 385 |
900–1000 | 392 | 392 |
1000–1100 | 398 | 398 |
1100–1200 | 403 | 403 |
1200–1300 | 408 | 408 |
1300–1400 | 412 | 412 |
1400–1500 | 415 | 415 |
1500–1600 | 418 | 418 |
1600–1700 | 421 | 421 |
1700–1800 | 424 | 431 |
1800–1900 | 426 | 444 |
1900–2000 | 428 | 458 |
TABLE 3
HAZARD TYPE 1 EXPLOSIVE IN A METAL-BUILT MOUNDED STORE
1 | 2 | 3 | 4 | 5 | 6 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
---|
0.1–25 | 34 | 45 | 40 | 68 | 6 |
25–50 | 37 | 45 | 48 | 74 | 7 |
50–75 | 40 | 45 | 54 | 80 | 8 |
75–100 | 43 | 48 | 66 | 86 | 9 |
100–150 | 49 | 55 | 86 | 97 | 12 |
150–200 | 54 | 62 | 104 | 109 | 15 |
200–300 | 68 | 76 | 136 | 136 | 23 |
300–400 | 83 | — | 165 | — | — |
400–450 | 89 | — | 178 | — | — |
450–500 | 96 | — | 191 | — | — |
500–600 | 108 | — | 216 | — | — |
600–700 | 119 | — | 238 | — | — |
700–800 | 130 | — | 260 | — | — |
800–900 | 140 | — | 280 | — | — |
900–1000 | 150 | — | 300 | — | — |
1000–1100 | 159 | — | 319 | — | — |
1100–1200 | 168 | — | 337 | — | — |
1200–1300 | 177 | — | 354 | — | — |
1300–1400 | 185 | — | 370 | — | — |
1400–1500 | 193 | — | 386 | — | — |
1500–1600 | 201 | — | 402 | — | — |
1600–1700 | 208 | — | 416 | — | — |
1700–1800 | 215 | — | 431 | — | — |
1800–1900 | 222 | — | 444 | — | — |
1900–2000 | 229 | — | 458 | — | — |
TABLE 4
HAZARD TYPE 1 EXPLOSIVE IN A METAL-BUILT UNMOUNDED STORE WITH NO DETONATOR ANNEX ATTACHED
1 | 2 | 3 | 4 | 5 | 6 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
---|
0.1–10 | 23 | 30 | 40 | 46 | 3 |
10–20 | 29 | 35 | 42 | 57 | 4 |
20–30 | 33 | 39 | 44 | 65 | 5 |
30–40 | 36 | 42 | 46 | 71 | 6 |
40–50 | 38 | 44 | 48 | 76 | 7 |
50–60 | 40 | 46 | 48 | 80 | 8 |
60–70 | 42 | 48 | 52 | 84 | 9 |
70–80 | 43 | 50 | 57 | 87 | 9 |
80–90 | 44 | 52 | 61 | 89 | 10 |
90–100 | 45 | 55 | 66 | 91 | 10 |
100–110 | 46 | 57 | 70 | 93 | 11 |
110–120 | 47 | 59 | 74 | 95 | 11 |
120–130 | 48 | 62 | 78 | 97 | 12 |
130–140 | 49 | 64 | 82 | 98 | 12 |
140–150 | 50 | 66 | 86 | 100 | 12 |
150–160 | 51 | 68 | 90 | 102 | 13 |
160–170 | 52 | 71 | 93 | 104 | 13 |
170–180 | 53 | 73 | 97 | 106 | 14 |
180–190 | 54 | 75 | 101 | 108 | 14 |
190–200 | 55 | 78 | 104 | 110 | 15 |
200–300 | 68 | 101 | 136 | 136 | 23 |
300–400 | 83 | 124 | 165 | 165 | 34 |
400–450 | 89 | 135 | 178 | 178 | 39 |
450–500 | 96 | 138 | 191 | 191 | 45 |
500–600 | 108 | 144 | 216 | 216 | 57 |
600–700 | 119 | 150 | 238 | 238 | 70 |
700–800 | 130 | 156 | 260 | 260 | 83 |
800–900 | 140 | 162 | 280 | 280 | 97 |
900–1000 | 150 | 168 | 300 | 300 | 111 |
1000–1100 | 159 | 168 | 319 | 319 | 111 |
1100–1200 | 168 | — | 337 | — | — |
1200–1300 | 177 | — | 354 | — | — |
1300–1400 | 185 | — | 370 | — | — |
1400–1500 | 193 | — | 386 | — | — |
1500–1600 | 201 | — | 402 | — | — |
1600–1700 | 208 | — | 416 | — | — |
1700–1800 | 215 | — | 431 | — | — |
1800–1900 | 222 | — | 444 | — | — |
1900–2000 | 229 | — | 458 | — | — |
TABLE 5
HAZARD TYPE 1 EXPLOSIVE IN A METAL-BUILT UNMOUNDED STORE WITH A DETONATOR ANNEX ATTACHED
1 | 2 | 3 | 4 | 5 | 6 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
---|
0.1–25 | 38 | 53 | 54 | 74 | 11 |
25–50 | 43 | 53 | 54 | 86 | 11 |
50–75 | 48 | 60 | 54 | 96 | 11 |
75–100 | 53 | 77 | 66 | 106 | 14 |
100–150 | 63 | 110 | 86 | 127 | 20 |
150–200 | 74 | 143 | 104 | 147 | 27 |
200–300 | 94 | 209 | 136 | 188 | 44 |
300–400 | 115 | 275 | 165 | 229 | 65 |
400–450 | 125 | 308 | 178 | 250 | 77 |
450–500 | 128 | 309 | 191 | 257 | 81 |
500–600 | 135 | 311 | 216 | 270 | 90 |
600–700 | 142 | 312 | 238 | 283 | 99 |
700–800 | 148 | 314 | 260 | 297 | 109 |
800–900 | 155 | 316 | 280 | 310 | 119 |
900–1000 | 162 | 318 | 300 | 324 | 129 |
1000–1100 | 169 | 319 | 319 | 337 | 140 |
1100–1200 | 175 | 321 | 337 | 350 | 152 |
1200–1300 | 182 | 323 | 354 | 364 | 163 |
1300–1400 | 189 | 325 | 370 | 377 | 176 |
1400–1500 | 195 | 326 | 386 | 391 | 188 |
1500–1600 | 202 | 328 | 402 | 404 | 202 |
1600–1700 | 209 | 330 | 416 | 417 | 215 |
1700–1800 | 215 | 332 | 431 | 431 | 229 |
1800–1900 | 222 | 333 | 444 | 444 | 244 |
1900–2000 | 229 | 335 | 458 | 458 | 259 |
TABLE 6
HAZARD TYPE 2 EXPLOSIVE, SOME OR ALL ITEMS BEING OF MORE THAN 0.7 KILOGRAMS NET MASS
1 | 2 | 3 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | Vulnerable building distance (metres) |
---|
0.1–25 | 45 | 90 |
25–50 | 88 | 176 |
50–75 | 108 | 216 |
75–100 | 129 | 238 |
100–150 | 148 | 296 |
150–200 | 168 | 336 |
200–300 | 191 | 382 |
300–400 | 207 | 414 |
400–450 | 213 | 426 |
450–500 | 219 | 438 |
500–600 | 226 | 452 |
600–700 | 233 | 466 |
700–800 | 240 | 480 |
800–900 | 248 | 496 |
900–1000 | 256 | 512 |
1000–1100 | 259 | 518 |
1100–1200 | 262 | 524 |
1200–1300 | 266 | 532 |
1300–1400 | 270 | 540 |
1400–1500 | 274 | 548 |
1500–1600 | 278 | 556 |
1600–1700 | 282 | 564 |
1700–1800 | 286 | 572 |
1800–1900 | 288 | 576 |
1900–2000 | 292 | 592 |
TABLE 7
HAZARD TYPE 2 EXPLOSIVE, EVERY ITEM BEING OF 0.7 KILOGRAMS NET MASS OR LESS
1 | 2 | 3 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) | Vulnerable building distance (metres) |
---|
0.1–25 | 37 | 76 |
25–50 | 43 | 86 |
50–75 | 47 | 94 |
75–100 | 51 | 102 |
100–150 | 56 | 112 |
150–200 | 60 | 120 |
200–300 | 66 | 132 |
300–400 | 71 | 142 |
400–450 | 73 | 146 |
450–500 | 74 | 148 |
500–600 | 76 | 152 |
600–700 | 78 | 158 |
700–800 | 81 | 162 |
800–900 | 84 | 164 |
900–1000 | 87 | 174 |
1000–1100 | 88 | 176 |
1100–1200 | 89 | 178 |
1200–1300 | 90 | 180 |
1300–1400 | 91 | 182 |
1400–1500 | 92 | 184 |
1500–1600 | 94 | 188 |
1600–1700 | 95 | 190 |
1700–1800 | 97 | 194 |
1800–1900 | 99 | 198 |
1900–2000 | 101 | 202 |
TABLE 8
HAZARD TYPE 3 EXPLOSIVE
1 | 2 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) |
---|
0.1–25 | — |
25–50 | 23 |
50–75 | 25 |
75–100 | 29 |
100–150 | 33 |
150–200 | 37 |
200–300 | 42 |
300–400 | 47 |
400–450 | 47 |
450–500 | 50 |
500–600 | 51 |
600–700 | 53 |
700–800 | 54 |
800–900 | 55 |
900–1000 | 63 |
1000–1100 | 70 |
1100–1200 | 71 |
1200–1300 | 72 |
1300–1400 | 73 |
1400–1500 | 74 |
1500–1600 | 75 |
1600–1700 | 76 |
1700–1800 | 78 |
1800–1900 | 79 |
1900–2000 | 80 |
TABLE 9
HAZARD TYPE 4 EXPLOSIVE
1 | 2 |
---|
Quantity of explosives (kilograms) | Low density distance (metres) |
---|
0.1–250 | — |
250–300 | 1 |
300–340 | 2 |
340–370 | 3 |
370–400 | 4 |
400–450 | 5 |
450–500 | 6 |
500–550 | 7 |
550–600 | 8 |
600–650 | 9 |
650–700 | 10 |
700–750 | 11 |
750–800 | 12 |
800–900 | 13 |
900–950 | 14 |
950–1000 | 15 |
1000–1100 | 16 |
1100–1150 | 17 |
1150–1200 | 18 |
1200–1300 | 19 |
1300–1350 | 20 |
1350–1400 | 21 |
1400–1450 | 22 |
1450–1550 | 23 |
1550–1600 | 24 |
1600–1650 | 25 |
1650–1700 | 26 |
1700–1800 | 27 |
1800–1850 | 28 |
1850–1900 | 29 |
1900–2000 | 30 |
Back to top