Type | Mercury in glass, nitrogen filled, graduated on the stem, enamel back. |
Length | Approximately 9 inches. |
Stem | Diameter 0.24 inches to 0.28 inches. |
Bulb | Spherical: made of a normal glass approved by |
the Board of Trade. Diameter, 0.35 inches ±0.05 inches. | |
Range | 50 degrees Fahrenheit to 150 degrees Fahrenheit with expansion chamber. Distance from the bottom of the bulb to the 50 degree line 2.75 inches to 3.15 inches. Distance from the 50 degree line to the 150 degree line not less than 4.75 inches. |
Immersion | A swelling is made in the stem to ensure that the thermometer shall be fixed in its brass collar so that the distance from the top of the collar to the bottom of the bulb is 2.4 inches + 0.05 inches. |
Graduation | Scale graduated in 1 degree Fahrenheit divisions. Every fifth degree and tenth degree to be indicated by longer lines. Figured at every tenth degree in full. |
Marking | " Abel Oil Cup " : Identification number : " Fahrenheit " : Maker's or Vendor's name or trade mark. |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: