53. The inspector shall not test any weight unless his testing equipment is—
(a)balanced in true equipoise;
(b)free from any influences likely in his opinion to affect its accuracy.
54. In testing any weight, the inspector shall—
(a)place the appropriate local or working standard on one pan of his testing equipment; and
(b)place counterpoises on the other pan so that the pointer exactly indicates zero; and
(c)replace the standard by the weight under test; and
(d)if the pointer does not then exactly indicate zero, add sufficient testing counterpoises to either pan to determine whether the weight falls within the prescribed limits of error:
55. Part III of Schedule 1 here to shall have effect for prescribing limits of error in relation to weights.