Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
Textual Amendments
6.—(1) The tests specified in sub-paragraphs (2), (3) and (4) below shall be carried out on a discontinuous totaliser under normal conditions of use.U.K.
(2) A minimum of three individual tests (including at least one at minimum load and at least one at maximum capacity) shall be carried out, each test involving the weighing of a quantity of suitable material as nearly as practicable equal to the minimum totalised load marked on the machine.
(3) In the case only of a discontinuous totaliser first passed as fit for use for trade before 29th April 1996, and if the person submitting it for testing so requests, the test at maximum capacity under sub-paragraph (2) above may be made with twenty separate loads and the words “as nearly as practicable equal to the minimum totalised load marked on the machine” in that sub-paragraph shall not have effect.
(4) Unless already included in the tests carried out under sub-paragraphs (2) and (3) above two further tests (which shall include at least five weighing cycles and a quantity of material not less than the minimum totalised load) shall be carried out, one at the minimum load and one at the maximum capacity.
(5) For each of the tests carried out under sub-paragraphs (2), (3) and (4) above, the inspector shall determine—
(a)the weight of material used in the test using the arrangements referred to in paragraph 5 above;
(b)the material testing error by ascertaining the difference between the weight of the material determined in accordance with sub-paragraph (a) above and the value of the weight of the material obtained from the totalisation indicating device.]
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: