12. A machine which is:
(a)made in accordance with an approved pattern and marked
in accordance with the published particulars of that pattern, or
(b)first stamped before 1st November 1988 and marked “Class B” in accordance with the provisions for beam scales in the Weights and Measures Regulations 1963,
is a Class II machine.
13. The specifications for non-graduated and graduated Class II machines are given in Table 2.
Maximum capacity “Max” | Lower limit of the minimum load “Min” | Scale interval “d” | Number of scale intervals “n” | Verification scale interval “e” |
---|---|---|---|---|
Notes 1. When a machine is provided with a rider its verification scale interval shall be the smaller of the following— (a) the verification scale interval of the machine not taking into account the rider, or (b) the scale interval of the rider device. 2. When graduated self or semi-self indicating machines are provided with a device for interpolation of reading, this shall not be taken into account when determining the verification scale interval of the machine. 3. When graduated self or semi-self indicating machines are provided with an indicating device on which the last figure is clearly differentiated from the other figures, the verification scale interval shall correspond to the last but one figure of the indication. 4. Machines of a maximum capacity equal to or greater than 1 kg of an actual scale interval of 100 mg and of a verification scale interval of 1 g may belong to this class of machine, provided that the last figure is clearly differentiated from the other figures. 5. In the case of machines where the weight indicating or printing is in carat (metric) units or units of the imperial system the relevant capacity and verification scale interval shall be the amounts in carat (metric) or imperial units respectively which are equivalent to those specified in the Table in terms of mg, g and kg. 6. Where the equivalent metric value for an imperial scale interval falls between ranges then the value shall be considered as belonging to the lower range. | ||||
Non-graduated machines | ||||
1 g ≤ Max < 5 g | 10 e | |||
5 g ≤ Max < 100 g | 10 e | 5 mg | ||
100 g ≤ Max < 200 g | 10 e | |||
200 g ≤ Max | 50 e | |||
Graduated machines | ||||
Non-self indicating machines | ||||
1 g ≤ Max < 50 g | 10 d | 1 mg ≤ d ≤ 5 mg | 200 ≤ n < 50 000 | d |
10 g ≤ Max < 50 g | 50 d | 10 mg ≤ d ≤ 50 mg | 1 000 ≤ n < 5 000 | 5 mg |
50 g ≤ Max ≤ 500 g | 10 d | 1 mg ≤ d ≤ 5 mg | 10 000 ≤ n ≤ 100 000 | d |
50 g ≤ Max < 5 kg | 50 d | 10 mg ≤ d ≤ 500 mg | 1 000 ≤ n < 10 000 | |
100 g ≤ Max ≤ 50 kg | 50 d | 10 mg ≤ d ≤ 500 mg | 10 000 ≤ n ≤ 100 000 | d |
5 kg ≤ Max | 50 d | 1 g ≤ d | 5 000 ≤ n < 10 000 | |
10 kg ≤ Max | 50 d | 1 g ≤ d | 10 000 ≤ n ≤ 100 000 | d |
Self and semi-self indicating machines | ||||
1 g ≤ Max ≤ 500 g | 10 d | 1 mg ≤ d ≤ 5 mg | 200 ≤ n ≤ 100 000 | d |
10 g ≤ Max ≤ 50 kg | 50 d | 10 mg ≤ d ≤ 500 mg | 1 000 ≤ n ≤ 100 000 | d |
5 kg ≤ Max | 50 d | 1 g ≤ d | 5 000 ≤ n ≤ 100 000 | d |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: