xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

regulation 6(b)

SCHEDULE 4E+W+S(Descriptive markings and verification markings: Extract from Part 1 of OIML R 61 and additional marking)

Descriptive markingsE+W+S

3.10  Filling instruments shall bear the following markings.

Commencement Information

I1Sch. 4 para. 3.10 in force at 17.7.2000, see reg. 1(1)

Markings shown in fullE+W+S

3.10.1  

• name or identification mark of the manufacturer
• name or identification mark of the importer (if applicable)
• serial number and type designation of the instrument
• product(s) designation (i.e. materials that may be weighed)
• temperature range (if applicable, see 2.5.1 in Schedule 2) in the form:…°C/…°C
• electrical supply voltage in the form:…V
• electrical supply frequency in the form:
…Hz
• working fluid pressure (if applicable) in the form:…kPa
• average number of loads per fill (if applicable)
• maximum fill (if applicable)
• rated minimum fill (if applicable)
• maximum rate of operation (if applicable) in the form:…loads per minute

Commencement Information

I2Sch. 4 para. 3.10.1 in force at 17.7.2000, see reg. 1(1)

Markings shown in codeE+W+S

3.10.2  

• pattern approval sign
• indication of the accuracy class X(x)
• reference value for accuracy class Ref(x)
• scale interval (if applicable) in the form:d=…
• maximum capacity in the form:Max=…
• minimum capacity (or minimum discharge where applicable) in the form:Min=…
• maximum additive tare in the form:T=+…
• maximum subtractive tare in the form:T=−…

An instrument may be verified for different materials for which different classes apply or which require different operating parameters to maintain limits of error. Marking shall be such that the alternative class or operating parameters are clearly associated with the appropriate material designation.

Commencement Information

I3Sch. 4 para. 3.10.2 in force at 17.7.2000, see reg. 1(1)

Presentation of descriptive markingsE+W+S

3.10.3  The descriptive markings shall be indelible and of a size, shape and clarity to enable legibility under normal conditions of use of the filling instrument. They shall be grouped together in a clearly visible place on the filling instrument, either on a data plate fixed to the instrument or on the filling instrument itself.

Commencement Information

I4Sch. 4 para. 3.10.3 in force at 17.7.2000, see reg. 1(1)

Verification marksE+W+S

Commencement Information

I5Sch. 4 para. 3.11 in force at 17.7.2000, see reg. 1(1)

PositionE+W+S

3.11.1  The filling instrument shall have a place for the application of verification marks. This place shall:

Commencement Information

I6Sch. 4 para. 3.11.1 in force at 17.7.2000, see reg. 1(1)

MountingE+W+S

3.11.2  Filling instruments required to bear verification marks shall have a verification mark support, at the place provided for above, which shall ensure the conservation of the marks.

When the mark is made with a stamp, this support may consist of a strip of lead or any other material with similar qualities, inserted into a plate fixed to the filling instrument or a cavity bored in the filling instrument itself.

Commencement Information

I7Sch. 4 para. 3.11.2 in force at 17.7.2000, see reg. 1(1)

Additional descriptive markingE+W+S

Filling instruments shall bear the additional descriptive marking “ R 61” which shall be presented in accordance with the provisions of clause 3.10.3 of Part 1 of OIML R 61 and, when a programmable display is used, the plate on the instrument shall bear that marking also.