http://www.legislation.gov.uk/uksi/2003/2761/schedule/4/paragraph/3.8.1/madeThe Weighing Equipment (Automatic Catchweighing Instruments) Regulations 2003Weights and measuresKing's Printer of Acts of Parliament2016-04-14WEIGHTS AND MEASURESThese Regulations implement, in Great Britain, International Recommendation OIML R51 of the Organisation Internationale de Métrologie Légale relating to automatic catchweighing instruments (Edition 1996 (E)), to the extent that the Recommendation applies to such instruments following the grant or renewal of a certificate of approval of a pattern by the Secretary of State under section 12 of the Weights and Measures Act 1985 (the 1985 Act).SCHEDULE 4(Descriptive Markings and Verification Marks: Principles from Part 1 of OIML R51 and Additional Descriptive Marking)Markings shown in full3.8.1.

name or identification mark of the manufacturer

name or identification mark of the importer (if applicable)

serial number and type designation of the instrument

maximum rate of operation (if applicable) in the form: . . .loads per minute

maximum speed of load transport system (if applicable) in the form: . . .m/s

electrical supply voltage in the form:…V

electrical supply frequency in the form:…Hz

working fluid pressure (if applicable) in the form:…kPa

adjustment range referred to set point (if applicable) in the form: ±… or % (of set point value)

This XML file does not appear to have any style information associated with it. The document tree is shown below.
<akomaNtoso xmlns:uk="https://www.legislation.gov.uk/namespaces/UK-AKN" xmlns:ukl="http://www.legislation.gov.uk/namespaces/legislation" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://docs.oasis-open.org/legaldocml/ns/akn/3.0" xsi:schemaLocation="http://docs.oasis-open.org/legaldocml/ns/akn/3.0 http://docs.oasis-open.org/legaldocml/akn-core/v1.0/cos01/part2-specs/schemas/akomantoso30.xsd">
<act name="uksi">
<meta>
<identification source="#">
<FRBRWork>
<FRBRthis value="http://www.legislation.gov.uk/id/uksi/2003/2761"/>
<FRBRuri value="http://www.legislation.gov.uk/id/uksi/2003/2761"/>
<FRBRdate date="2003-11-02" name="made"/>
<FRBRauthor href="http://www.legislation.gov.uk/id/government/uk"/>
<FRBRcountry value="GB-UKM"/>
<FRBRsubtype value="regulation"/>
<FRBRnumber value="2761"/>
<FRBRname value="S.I. 2003/2761"/>
<FRBRprescriptive value="true"/>
</FRBRWork>
<FRBRExpression>
<FRBRthis value="http://www.legislation.gov.uk/uksi/2003/2761/made"/>
<FRBRuri value="http://www.legislation.gov.uk/uksi/2003/2761/made"/>
<FRBRdate date="2003-11-02" name="made"/>
<FRBRauthor href="#"/>
<FRBRlanguage language="eng"/>
</FRBRExpression>
<FRBRManifestation>
<FRBRthis value="http://www.legislation.gov.uk/uksi/2003/2761/made/data.akn"/>
<FRBRuri value="http://www.legislation.gov.uk/uksi/2003/2761/made/data.akn"/>
<FRBRdate date="2024-11-27Z" name="transform"/>
<FRBRauthor href="http://www.legislation.gov.uk"/>
<FRBRformat value="application/akn+xml"/>
</FRBRManifestation>
</identification>
<lifecycle source="#">
<eventRef refersTo="#made" date="2003-11-02" eId="date-made" source="#"/>
<eventRef refersTo="#laid" date="2003-11-04" eId="date-laid-1" source="#united-kingdom-parliament"/>
<eventRef refersTo="#coming-into-force" date="2004-03-03" eId="date-cif-1" source="#"/>
</lifecycle>
<analysis source="#">
<otherAnalysis source=""/>
</analysis>
<references source="#">
<TLCOrganization eId="united-kingdom-parliament" href="" showAs="UnitedKingdomParliament"/>
<TLCEvent eId="made" href="" showAs="Made"/>
<TLCEvent eId="laid" href="" showAs="Laid"/>
<TLCEvent eId="cif" href="" showAs="ComingIntoForce"/>
</references>
<proprietary xmlns:ukm="http://www.legislation.gov.uk/namespaces/metadata" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dct="http://purl.org/dc/terms/" source="#">
<dc:identifier>http://www.legislation.gov.uk/uksi/2003/2761/schedule/4/paragraph/3.8.1/made</dc:identifier>
<dc:title>The Weighing Equipment (Automatic Catchweighing Instruments) Regulations 2003</dc:title>
<dc:subject>Weights and measures</dc:subject>
<dc:publisher>King's Printer of Acts of Parliament</dc:publisher>
<dc:modified>2016-04-14</dc:modified>
<dc:subject scheme="SIheading">WEIGHTS AND MEASURES</dc:subject>
<dc:description>These Regulations implement, in Great Britain, International Recommendation OIML R51 of the Organisation Internationale de Métrologie Légale relating to automatic catchweighing instruments (Edition 1996 (E)), to the extent that the Recommendation applies to such instruments following the grant or renewal of a certificate of approval of a pattern by the Secretary of State under section 12 of the Weights and Measures Act 1985 (the 1985 Act).</dc:description>
<ukm:SecondaryMetadata>
<ukm:DocumentClassification>
<ukm:DocumentCategory Value="secondary"/>
<ukm:DocumentMainType Value="UnitedKingdomStatutoryInstrument"/>
<ukm:DocumentStatus Value="final"/>
<ukm:DocumentMinorType Value="regulation"/>
</ukm:DocumentClassification>
<ukm:Year Value="2003"/>
<ukm:Number Value="2761"/>
<ukm:Made Date="2003-11-02"/>
<ukm:Laid Date="2003-11-04" Class="UnitedKingdomParliament"/>
<ukm:ComingIntoForce>
<ukm:DateTime Date="2004-03-03"/>
</ukm:ComingIntoForce>
<ukm:ISBN Value="0110481135"/>
</ukm:SecondaryMetadata>
<ukm:Alternatives>
<ukm:Alternative Date="2008-12-04" URI="http://www.legislation.gov.uk/uksi/2003/2761/pdfs/uksi_20032761_en.pdf" Title="Print Version"/>
</ukm:Alternatives>
<ukm:Statistics>
<ukm:TotalParagraphs Value="54"/>
<ukm:BodyParagraphs Value="17"/>
<ukm:ScheduleParagraphs Value="37"/>
<ukm:AttachmentParagraphs Value="0"/>
<ukm:TotalImages Value="1"/>
</ukm:Statistics>
</proprietary>
</meta>
<body>
<hcontainer name="schedules">
<hcontainer name="schedule" eId="schedule-4">
<num>SCHEDULE 4</num>
<heading>
(Descriptive Markings and Verification Marks: Principles from Part 1 of
<abbr class="acronym" title="Organisation Internationale de Métrologie Légale" xml:lang="fr">OIML</abbr>
R51 and Additional Descriptive Marking)
</heading>
<hcontainer name="crossheading" class="schGroup7">
<heading>Markings shown in full</heading>
<paragraph eId="schedule-4-paragraph-3.8.1" uk:target="true" class="schProv1">
<num>3.8.1.</num>
<content>
<blockList class="unordered bullet" ukl:Name="UnorderedList" ukl:Decoration="bullet">
<item>
<p>name or identification mark of the manufacturer</p>
</item>
<item>
<p>name or identification mark of the importer (if applicable)</p>
</item>
<item>
<p>serial number and type designation of the instrument</p>
</item>
<item>
<p>maximum rate of operation (if applicable) in the form: . . .loads per minute</p>
</item>
<item>
<p>maximum speed of load transport system (if applicable) in the form: . . .m/s</p>
</item>
<item>
<p>electrical supply voltage in the form:…V</p>
</item>
<item>
<p>electrical supply frequency in the form:…Hz</p>
</item>
<item>
<p>working fluid pressure (if applicable) in the form:…kPa</p>
</item>
<item>
<p>adjustment range referred to set point (if applicable) in the form: ±… or % (of set point value)</p>
</item>
</blockList>