SCHEDULES

SCHEDULE 1AUTHORISED PROJECT

PART 3REQUIREMENTS

Detailed offshore design parametersI12

1

The total number of wind turbine generators comprised in the authorised project must not exceed 180.

2

Subject to sub-paragraph (3), each wind turbine generator forming part of the authorised project must not—

a

exceed a height of 370 metres when measured from LAT to the tip of the vertical blade;

b

exceed a rotor diameter of 305 metres;

c

be less than 42.43 metres from LAT to the lowest point of the rotating blade; and

d

be less than 810 metres from the nearest wind turbine generator in all directions.

3

The minimum distance in sub-paragraph (2)(d) between each wind turbine generator is to be measured from the centre point of the wind turbine generator.

4

Wind turbine generator foundation structures forming part of the authorised project must be one of either monopile foundations, mono suction bucket foundations or jacket foundations.

5

No wind turbine generator—

a

jacket foundations employing pin piles forming part of the authorised project may—

i

have a pin pile diameter of greater than four metres; and

ii

employ more than 16 pin piles per jacket foundation; and

b

monopile foundation forming part of the authorised project may have a diameter greater than 15 metres.

6

The total combined seabed footprint area for wind turbine generator foundations must not exceed—

a

302,180 square metres excluding scour protection; and

b

985,240 square metres including scour protection.

7