Search Legislation

The Air Quality (Ozone) (Wales) Regulations 2003

 Help about what version

What Version

 Help about opening options

Opening OptionsExpand opening options

Status:

This is the original version (as it was originally made). This item of legislation is currently only available in its original format.

Regulation 4(7)

SCHEDULE 5DATA QUALITY OBJECTIVES AND COMPILATION OF RESULTS OF AIR QUALITY ASSESSMENT

PART IData quality objectives

The following data quality objectives for allowed uncertainty of assessment methods and of minimum time coverage and of data capture of measurement are provided to guide quality-assurance programmes:

For ozone, NO and NO2

The uncertainty (on a 95% confidence interval) of the measurement methods must be evaluated in accordance with the principles laid down in the “Guide to the Expression of Uncertainty of Measurements” (ISO 1993) or the methodology in ISO 5725-1 “Accuracy (trueness and precision) of measurement methods and results” (ISO 1994) (1) or equivalent. The percentages for uncertainty in the table are given for individual measurements, averaged over the period for calculating target values and long-term objectives, for a 95% confidence interval. The uncertainty for continuous fixed measurements should be interpreted as being applicable in the region of the concentration used for the appropriate threshold.

The uncertainty for modelling and objective estimation means the maximum deviation of the measured and calculated concentration levels, over the period for calculating the appropriate threshold, without taking into account the timing of events.

“Time coverage” means the percentage of time considered for settling the threshold value during which the pollutant is measured.

“Data capture” means the ratio of the time for which the instrument produces valid data, to the time for which the statistical parameter or aggregated value is to be calculated.

The requirements for minimum data capture and time coverage do not include losses of data due to the regular calibration or normal maintenance of the instrumentation.

Continuous fixed measurement
Uncertainty of individual measurements15%
Minimum data capture90% during summer 75% during winter
Indicative measurement
Uncertainty of individual measurements30%
Minimum data capture90%
Minimum time coverage>10% during summer
Modelling
Uncertainty
1 hour averages (daytime)50%
8 hours daily maximum50%
Objective estimation
Uncertainty75%

PART IIResults of air quality assessment

The following information should be compiled for zones within which sources other than measurement are employed to supplement information from measurement:

  • a description of the assessment activities carried out;

  • specific methods used, with references to descriptions of the method;

  • sources of data and information;

  • a description of results, including uncertainties and, in particular, the extent of any area within the zone over which concentrations exceed long-term objectives or target values;

  • for long-term objectives or target values whose object is the protection of human health, the population potentially exposed to concentrations in excess of the threshold.

Where possible, the National Assembly must ensure that maps are compiled showing concentration distributions within each zone.

(1)

Copies of these International Standards Organisation publications can be purchased from the British Standards Institution “BSI” sales department either by telephone on 020-8996-9001 or by post from the BSI, Standards House, 389 Chiswick High Road, London, W4 4AL

Back to top

Options/Help