Council Directive 98/57/ECDangos y teitl llawn

Council Directive 98/57/EC of 20 July 1998 on the control of Ralstonia solanacearum (Smith) Yabuuchi et al.

1.

[F1Count the mean number of typical fluorescent cells per field of view (c).

2.

Calculate the number of typical fluorescent cells per microscope slide window (C).

C = c × S/s

where S = surface area of window of multispot slide
and s = surface area of objective field
s = πi 2 /4G 2 K 2 where i = field coefficient (varies from 8 to 24 depending upon ocular type)
K = tube coefficient (1 or 1,25)
G = magnification of objective (100 ×, 40 × etc.).
3.

Calculate the number of typical fluorescent cells per ml of re-suspended pellet (N).

N = C × 1 000 /y × F

where y = volume of re-suspended pellet on each window
and F = dilution factor of re-suspended pellet.]