Directive 2004/107/EC of the European Parliament and of the CouncilDangos y teitl llawn

Directive 2004/107/EC of the European Parliament and of the Council of 15 December 2004 relating to arsenic, cadmium, mercury, nickel and polycyclic aromatic hydrocarbons in ambient air

II.Microscale sitingU.K.

The following guidelines should be met as far as practicable:U.K.

  • the flow around the inlet sampling probe should be unrestricted, without any obstructions affecting the airflow in the vicinity of the sampler (normally some metres away from buildings, balconies, trees and other obstacles and at least 0,5 m from the nearest building in the case of sampling points representing air quality at the building line);

  • in general, the inlet sampling point should be between 1,5 m (the breathing zone) and 4 m above the ground. Higher positions (up to 8 m) may be necessary in some circumstances. Higher siting may also be appropriate if the station is representative of a large area;

  • the inlet probe should not be positioned in the immediate vicinity of sources in order to avoid direct intake of emissions unmixed with ambient air;

  • the sampler’s exhaust outlet should be positioned so that recirculation of exhaust air to the sample inlet is avoided;

  • traffic-orientated sampling points should be at least 25 metres from the edge of major junctions and at least 4 m from the centre of the nearest traffic lane; inlets should be sited so as to be representative of air quality near the building line;

  • for the deposition measurements in rural background areas, the EMEP guidelines and criteria should be applied as far as practicable and where not provided for in the Annexes.

The following factors may also be taken into account:

  • interfering sources

  • security

  • access

  • availability of electrical power and telephone communications

  • visibility of the site in relation to its surroundings

  • safety of the public and operators

  • the desirability of co-locating sampling points for different pollutants

  • planning requirements.