Chwilio Deddfwriaeth

Directive 2014/32/EU of the European Parliament and of the CouncilDangos y teitl llawn

Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (recast) (Text with EEA relevance)

 Help about advanced features

Nodweddion Uwch

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

Mae hon yn eitem o ddeddfwriaeth sy’n deillio o’r UE

Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3

Status:

EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.

ANNEX VIIU.K.

MEASURING SYSTEMS FOR THE CONTINUOUS AND DYNAMIC MEASUREMENT OF QUANTITIES OF LIQUIDS OTHER THAN WATER (MI-005)U.K.

The relevant essential requirements of Annex I, the specific requirements of this Annex and the conformity assessment procedures listed in this Annex, apply to measuring systems intended for the continuous and dynamic measurement of quantities (volumes or masses) of liquids other than water. If appropriate, the terms ‘volume, and L’ in this Annex can be read as: ‘mass and kg’.

DEFINITIONSU.K.

MeterAn instrument designed to measure continuously, memorise and display the quantity at metering conditions of liquid flowing through the measurement transducer in a closed, fully charged conduit.
CalculatorA part of a meter that receives the output signals from the measurement transducer(s) and possibly, from associated measuring instruments and displays the measurement results.
Associated measuring instrumentAn instrument connected to the calculator for measuring certain quantities which are characteristic of the liquid, with a view to make a correction and/or conversion.
Conversion Device

A part of the calculator which by taking account of the characteristics of the liquid (temperature, density, etc.) measured using associated measuring instruments, or stored in a memory, automatically converts:

  • the volume of the liquid measured at metering conditions into a volume at base conditions and/or into mass, or

  • the mass of the liquid measured at metering conditions into a volume at metering conditions and/or into a volume at base conditions

Note:

A conversion device includes the relevant associated measuring instruments.

Base conditionsThe specified conditions to which the measured quantity of liquid at metering conditions is converted.
Measuring SystemA system that comprises the meter itself and all devices required to ensure correct measurement or intended to facilitate the measuring operations.
Fuel dispenserA measuring system intended for the refuelling of motor vehicles, small boats and small aircraft.
Self-service arrangementAn arrangement that allows the customer to use a measuring system for the purpose of obtaining liquid for his own use.
Self-service deviceA specific device that is part of a self-service arrangement and which allows one of more measuring systems to perform in this self-service arrangement.
Minimum measured quantity (MMQ)The smallest quantity of liquid for which the measurement is metrologically acceptable for the measuring system.
Direct indication

The indication, either volume or mass, corresponding to the measure and that the meter is physically capable of measuring.

Note:

The direct indication may be converted into another quantity using a conversion device.

Interruptible/non-interruptibleA measuring system is considered as interruptible/non-interruptible when the liquid flow can/cannot be stopped easily and rapidly.
Flowrate rangeThe range between the minimum flowrate (Qmin) and maximum flowrate (Qmax).

SPECIFIC REQUIREMENTSU.K.

1. Rated operating conditions U.K.

The manufacturer shall specify the rated operating conditions for the instrument, in particular;

1.1. The flowrate range U.K.

The flowrate range is subject to the following conditions:

(i)

the flowrate range of a measuring system shall be within the flowrate range of each of its elements, in particular the meter.

(ii)

meter and measuring system:

Table 1
Specific measuring systemCharacteristic of liquidMinimum ratio of Qmax: Qmin
Fuel dispensersNot Liquefied gases10: 1
Liquefied gases5: 1
Measuring systemCryogenic liquids5: 1
Measuring systems on pipeline and systems for loading shipsAll liquidsSuitable for use
All other measuring systemsAll liquids4: 1
1.2.The properties of the liquid to be measured by the instrument by specifying the name or type of the liquid or its relevant characteristics, for example:U.K.
  • Temperature range;

  • Pressure range;

  • Density range;

  • Viscosity range.

1.3.The nominal value of the AC voltage supply and/or limits of the DC voltage supply.U.K.
1.4.The base conditions for converted values.U.K.
Note:U.K.

Point 1.4 is without prejudice to the Member States’ obligations to require use of a temperature of either 15 °C in accordance with Article 12(2) of Council Directive 2003/96/EC of 27 October 2003 restructuring the Community framework for the taxation of energy products and electricity(1).

2. Accuracy classification and maximum permissible errors (MPEs) U.K.

2.1.For quantities equal to or greater than 2 litres the MPE on indications is:U.K.
Table 2
Accuracy Class
0,30,51,01,52,5
Measuring systems (A)0,3 %0,5 %1,0 %1,5 %2,5 %
Meters (B)0,2 %0,3 %0,6 %1,0 %1,5 %
2.2.For quantities less than two litres the MPE on indications is:U.K.
Table 3
Measured volume VMPE
V < 0,1 l4 × value in Table 2, applied to 0,1 L
0,1 l ≤ V < 0,2 l4 × value in Table 2
0,2 l ≤ V < 0,4 l2 × value in Table 2, applied to 0,4 L
0,4 l ≤ V < 1 l2 × value in Table 2
1 l ≤ V < 2 lValue in Table 2, applied to 2 L
2.3.However, no matter what the measured quantity may be, the magnitude of the MPE is given by the greater of the following two values:U.K.
  • the absolute value of the MPE given in Table 2 or Table 3,

  • the absolute value of the MPE for the minimum measured quantity (Emin).

2.4.1.For minimum measured quantities greater than or equal to 2 litres the following conditions apply:U.K.
  • Condition 1

    Emin shall fulfil the condition: Emin ≥ 2 R, where R is the smallest scale interval of the indication device.

  • Condition 2

    Emin is given by the formula: , where:

    • MMQ is the minimum measured quantity,

    • A is the numerical value specified in line A of Table 2.

2.4.2.For minimum measured quantities of less than two litres, the above mentioned condition 1 applies and Emin is twice the value specified in Table 3, and related to line A of Table 2.U.K.
2.5. Converted indication U.K.

In the case of a converted indication the MPEs are as in line A of Table 2.

2.6. Conversion devices U.K.

MPEs on converted indications due to a conversion device are equal to ± (A — B), A and B being the values specified in Table 2.

Parts of conversion devices that can be tested separately

(a) Calculator U.K.

MPEs on quantities of liquid indications applicable to calculation, positive or negative, are equal to one-tenth of the MPEs as defined in line A of Table 2.

(b) Associated measuring instruments U.K.

Associated measuring instruments shall have an accuracy at least as good as the values in Table 4:

Table 4
MPE on MeasurementsAccuracy classes of the measuring system
0,30,51,01,52,5
Temperature± 0,3 °C± 0,5 °C± 1,0 °C
Pressure

Less than 1 MPa: ± 50 kPa

From 1 to 4 MPa: ± 5 %

Over 4 MPa: ± 200 kPa

Density± 1 kg/m3± 2 kg/m3± 5 kg/m3

These values apply to the indication of the characteristic quantities of the liquid displayed by the conversion device.

(c) Accuracy for calculating function U.K.

The MPE for the calculation of each characteristic quantity of the liquid, positive or negative, is equal to two fifths of the value fixed in (b).

2.7.The requirement (a) in point 2.6 applies to any calculation, not only conversion.U.K.
2.8.The measuring system shall not exploit the MPEs or systematically favour any party.U.K.

3. Maximum permissible effect of disturbances U.K.

3.1.The effect of an electromagnetic disturbance on a measuring system shall be one of the following:U.K.
  • the change in the measurement result is not greater than the critical change value as defined in point 3.2, or

  • the indication of the measurement result shows a momentary variation that cannot be interpreted, memorised or transmitted as a measuring result. Furthermore, in the case of an interruptible system, this can also mean the impossibility to perform any measurement, or

  • the change in the measurement result is greater than the critical change value, in which case the measuring system shall permit the retrieval of the measuring result just before the critical change value occurred and cut off the flow.

3.2.The critical change value is the greater of MPE/5 for a particular measured quantity or Emin.U.K.

4. Durability U.K.

After an appropriate test, taking into account the period of time estimated by the manufacturer, has been performed, the following criterion shall be satisfied:

The variation of the measurement result after the durability test, when compared with the initial measurement result, shall not exceed the value for meters specified in line B of table 2.

5. Suitability U.K.

5.1.For any measured quantity relating to the same measurement, the indications provided by various devices shall not deviate one from another by more than one scale interval where devices have the same scale interval. In the case where the devices have different scale intervals, the deviation shall not be more than that of the greatest scale interval.U.K.

However, in the case of a self-service arrangement the scale intervals of the main indicating device on the measuring system and the scale intervals of the self-service device shall be the same and results of measurement shall not deviate one from another.

5.2.It shall not be possible to divert the measured quantity in normal conditions of use unless it is readily apparent.U.K.
5.3.Any percentage of air or gas not easily detectable in the liquid shall not lead to a variation of error greater than:U.K.
  • 0,5 % for liquids other than potable liquids and for liquids of a viscosity not exceeding 1 mPa.s, or

  • 1 % for potable liquids and for liquids of a viscosity exceeding 1 mPa.s.

However, the allowed variation shall never be smaller than 1 % of MMQ. This value applies in the case of air or gas pockets.

5.4. Instruments for direct sales U.K.
5.4.1.A measuring system for direct sales shall be provided with means for resetting the display to zero.U.K.

It shall not be possible to divert the measured quantity.

5.4.2.The display of the quantity on which the transaction is based shall be permanent until all parties in the transaction have accepted the measurement result.U.K.
5.4.3.Measuring systems for direct sales shall be interruptible.U.K.
5.4.4.Any percentage of air or gas in the liquid shall not lead to a variation of error greater than the values specified in point 5.3.U.K.
5.5. Fuel Dispensers U.K.
5.5.1.Displays on fuel dispensers shall not be capable of being reset to zero during a measurement.U.K.
5.5.2.The start of a new measurement shall be inhibited until the display has been reset to zero.U.K.
5.5.3.Where a measuring system is fitted with a price display, the difference between the indicated price and the price calculated from the unit price and the indicated quantity shall not exceed the price corresponding to Emin. However this difference need not be less than the smallest monetary value.U.K.

6. Power supply failure U.K.

A measuring system shall either be provided with an emergency power supply device that will safeguard all measuring functions during the failure of the main power supply device or be equipped with means to save and display the data present in order to permit the conclusion of the transaction in progress and with means to stop the flow at the moment of the failure of the main power supply device.

7. Putting into use U.K.

Table 5
a

However, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers.

Note: However, the manufacturer may specify a better accuracy for a certain type of measuring system.

Accuracy ClassTypes of Measuring system
0,3Measuring systems on pipeline
0,5

All measuring systems if not differently stated elsewhere in this Table, in particular:

  • fuel dispensers (not for liquefied gases),

  • measuring systems on road tankers for liquids of low viscosity (< 20 mPa.s)

  • measuring systems for (un)loading ships and rail and road tankersa

  • measuring systems for milk

  • measuring systems for refuelling aircraft

1,0Measuring systems for liquefied gases under pressure measured at a temperature equal to or above – 10 °C

Measuring systems normally in class 0,3 or 0,5 but used for liquids

  • whose temperature is less than – 10 °C or greater than 50 °C

  • whose dynamic viscosity is higher than 1 000 mPa.s

  • whose maximum volumetric flowrate is not higher than 20 L/h

1,5Measuring systems for liquefied carbon dioxide
Measuring systems for liquefied gases under pressure measured at a temperature below – 10 °C (other than cryogenic liquids)
2,5measuring systems for cryogenic liquids (temperature below – 153 °C)

8. Units of measurement U.K.

The metered quantity shall be displayed in millilitres, cubic centimetres, litres, cubic metres, grams, kilograms or tonnes.

CONFORMITY ASSESSMENTU.K.

The conformity assessment procedures referred to in Article 17 that the manufacturer can choose between are:

B + F or B + D or H1 or G.

Yn ôl i’r brig

Options/Help

Print Options

You have chosen to open the Whole Directive

The Whole Directive you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

You have chosen to open Schedules only

Y Rhestrau you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

Gweler y wybodaeth ychwanegol ochr yn ochr â’r cynnwys

Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted version that was used for the EU Official Journal
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Llinell Amser Newidiadau

Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.

Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.

Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.

Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill