- Y Diweddaraf sydd Ar Gael (Diwygiedig)
- Pwynt Penodol mewn Amser (31/12/2020)
- Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE)
Council Regulation (EEC) No 3821/85 of 20 December 1985 on recording equipment in road transport
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3
Point in time view as at 31/12/2020.
There are currently no known outstanding effects for the Council Regulation (EEC) No 3821/85, Division 6. .
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
The services available are detailed in the following table:
Data transmission services
Service name | Description |
---|---|
ReadDataByIdentifier | The client requests the transmission of the current value of a record with access by recordDataIdentifier |
WriteDataByIdentifier | The client requests to write a record accessed by recordDataIdentifier |
[CPR_050] The ReadDataByIdentifier service is used by the client to request data record values from a server. The data are identified by a recordDataIdentifier. It is the VU manufacturer's responsibility that the server conditions are met when performing this service.
[CPR_051] The message formats for the ReadDataByIdentifier primitives are detailed in the following tables:
ReadDataByIdentifier request message
Byte # | Parameter Name | Hex value | Mnemonic |
---|---|---|---|
#1 | Format byte — physical addressing | 80 | FMT |
#2 | Target address byte | EE | TGT |
#3 | Source address byte | tt | SRC |
#4 | Additional length byte | 03 | LEN |
#5 | ReadDataByIdentifier Request Service Id | 22 | RDBI |
#6 and #7 | [X1recordDataIdentifier = (a value from Table 8)] | xxxx | RDI_ … |
#8 | Checksum | 00-FF | CS |
Editorial Information
ReadDataByIdentifier positive response message
Byte # | Parameter Name | Hex value | Mnemonic |
---|---|---|---|
#1 | Format byte — physical addressing | 80 | FMT |
#2 | Target address byte | tt | TGT |
#3 | Source address byte | EE | SRC |
#4 | Additional length byte | m+3 | LEN |
#5 | ReadDataByIdentifier Positive Response Service Id | 62 | RDBIPR |
#6 and #7 | recordDataIdentifier = (the same value as bytes #6 and #7 Table 25) | xxxx | RDI_ … |
#8 to #m+7 | dataRecord() = (data#1 : data#m) | xx : xx | DREC_DATA1 : DREC_DATAm |
#m+8 | Checksum | 00-FF | CS |
ReadDataByIdentifier negative response message
Byte # | Parameter Name | Hex value | Mnemonic |
---|---|---|---|
#1 | Format byte — physical addressing | 80 | FMT |
#2 | Target address byte | tt | TGT |
#3 | Source address byte | EE | SRC |
#4 | Additional length byte | 03 | LEN |
#5 | NegativeResponse Service Id | 7F | NR |
#6 | ReadDataByIdentifier Request Service Id | 22 | RDBI |
#7 | ResponseCode = (requestOutOfRange incorrectMessageLength | 31 13 | RC_ROOR RC_IML |
conditionsNotCorrect) | 22 | RC_CNC | |
#8 | Checksum | 00-FF | CS |
[CPR_052] The parameter recordDataIdentifier (RDI_) in the ReadDataByIdentifier request message identifies a data record.
[CPR_053] recordDataIdentifier values defined by this document are shown in the table below.
The recordDataIdentifier table consists of four columns and multiple lines.
The first column (Hex) includes the ‘ hex value ’ assigned to the recordDataIdentifier specified in the third column.
The second column (Data element) specifies the data element of Appendix 1 on which the recordDataIdentifier is based (transcoding is sometimes necessary).
The third column (Description) specifies the corresponding recordDataIdentifier name.
The fourth column (Mnemonic) specifies the mnemonic of this recordDataIdentifier.
Definition of recordDataIdentifier values
Hex | Data element | recordDataIdentifier Name (see format in Section 8.2) | Mnemonic |
---|---|---|---|
F90B | CurrentDateTime | TimeDate | RDI_TD |
F912 | HighResOdometer | HighResolutionTotalVehicleDistance | RDI_HRTVD |
F918 | K-ConstantOfRecordingEquipment | Kfactor | RDI_KF |
F91C | L-TyreCircumference | LfactorTyreCircumference | RDI_LF |
F91D | W-VehicleCharacteristicConstant | WvehicleCharacteristicFactor | RDI_WVCF |
F921 | TyreSize | TyreSize | RDI_TS |
F922 | nextCalibrationDate | NextCalibrationDate | RDI_NCD |
F92C | SpeedAuthorised | SpeedAuthorised | RDI_SA |
F97D | vehicleRegistrationNation | RegisteringMemberState | RDI_RMS |
F97E | VehicleRegistrationNumber | VehicleRegistrationNumber | RDI_VRN |
F190 | VehicleIdentificationNumber | VIN | RDI_VIN |
[CPR_054] The parameter dataRecord (DREC_) is used by the ReadDataByIdentifier positive response message to provide the data record value identified by the recordDataIdentifier to the client (tester). Data formats are specified in Section 8. Additional user optional dataRecords including VU specific input, internal and output data may be implemented, but are not defined in this document.
[CPR_056] The WriteDataByIdentifier service is used by the client to write data record values to a server. The data are identified by a recordDataIdentifier. It is the VU manufacturer's responsibility that the server conditions are met when performing this service. To update the parameters listed in Table 28 the VU must be in CALIBRATION mode.
[CPR_057] The message formats for the WriteDataByIdentifier primitives are detailed in the following tables:
WriteDataByIdentifier request message
Byte # | Parameter Name | Hex value | Mnemonic |
---|---|---|---|
#1 | Format byte — physical addressing | 80 | FMT |
#2 | Target address byte | EE | TGT |
#3 | Source address byte | tt | SRC |
#4 | Additional length byte | m+3 | LEN |
#5 | WriteDataByIdentifier request service Id | 2E | WDBI |
#6 and #7 | recordDataIdentifier = (a value from Table 28) | xxxx | RDI_ … |
#8 to #m+7 | dataRecord() = (data#1 : data#m) | xx : xx | DREC_DATA1 : DREC_DATAm |
#m+8 | Checksum | 00-FF | CS |
WriteDataByIdentifier positive response message
Byte # | Parameter Name | Hex value | Mnemonic |
---|---|---|---|
#1 | Format byte — physical addressing | 80 | FMT |
#2 | Target address byte | tt | TGT |
#3 | Source address byte | EE | SRC |
#4 | Additional length byte | 03 | LEN |
#5 | WriteDataByIdentifier positive response service Id | 6E | WDBIPR |
#6 and #7 | recordDataIdentifier = (the same value as bytes #6 and #7 Table 29) | xxxx | RDI_ … |
#8 | Checksum | 00-FF | CS |
WriteDataByIdentifier negative response message
Byte # | Parameter Name | Hex value | Mnemonic |
---|---|---|---|
#1 | Format byte — physical addressing | 80 | FMT |
#2 | Target address byte | tt | TGT |
#3 | Source address byte | EE | SRC |
#4 | Additional length byte | 03 | LEN |
#5 | NegativeResponse Service Id | 7F | NR |
#6 | WriteDataByIdentifier request service Id | 2E | WDBI |
#7 | ResponseCode = (requestOutOfRange incorrectMessageLength | 31 13 | RC_ROOR RC_IML |
conditionsNotCorrect) | 22 | RC_CNC | |
#8 | Checksum | 00-FF | CS |
The parameter recordDataIdentifier (RDI_) is defined in Table 28.
The parameter dataRecord (DREC_) is used by the WriteDataByIdentifier request message to provide the data record values identified by the recordDataIdentifier to the server (VU). Data formats are specified in Section 8.] ]
The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Y Rhestrau you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys