Chwilio Deddfwriaeth

Commission Regulation (EEC) No 000/90 (repealed)Dangos y teitl llawn

Commission Regulation (EEC) No 000/90 of 17 September 1990 determining Community methods for the analysis of wines (repealed)

 Help about what version

Pa Fersiwn

 Help about advanced features

Nodweddion Uwch

 Help about UK-EU Regulation

Deddfwriaeth yn deillio o’r UE

Pan adawodd y DU yr UE, cyhoeddodd legislation.gov.uk ddeddfwriaeth yr UE a gyhoeddwyd gan yr UE hyd at ddiwrnod cwblhau’r cyfnod gweithredu (31 Rhagfyr 2020 11.00 p.m.). Ar legislation.gov.uk, mae'r eitemau hyn o ddeddfwriaeth yn cael eu diweddaru'n gyson ag unrhyw ddiwygiadau a wnaed gan y DU ers hynny.

Close

Mae'r eitem hon o ddeddfwriaeth yn tarddu o'r UE

Mae legislation.gov.uk yn cyhoeddi fersiwn y DU. Mae EUR-Lex yn cyhoeddi fersiwn yr UE. Mae Archif Gwe Ymadael â’r UE yn rhoi cipolwg ar fersiwn EUR-Lex o ddiwrnod cwblhau’r cyfnod gweithredu (31 Rhagfyr 2020 11.00 p.m.).

Changes over time for: Division 4.

 Help about opening options

Version Superseded: 01/08/2009

Status:

Point in time view as at 09/03/2005.

Changes to legislation:

There are currently no known outstanding effects by UK legislation for Commission Regulation (EEC) No 000/90 (repealed), Division 4.. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

4.REFERENCE METHODU.K.

4.1.Apparatus:U.K.

Normal laboratory equipment, and in particular:

4.1.1.A Pyrex pycnometer(1), of approximately 100 ml capacity, with a removable ground-glass jointed thermometer calibrated in tenths of a degree from 10 to 30 °C (Figure 1). The thermometer must be standardized.U.K.

The pycnometer has a side tube 25 mm in length and 1 mm (maximum) in internal diameter, ending in a conical ground joint. This side tube may be capped by a ‘reservoir stopper’ consisting of a conical ground-glass joint tube and terminating in a drawn-out section. This stopper serves as an expansion chamber.

The two ground joints of the apparatus should be prepared with great care.

4.1.2.A tare bottle, consisting of a vessel with the same outside volume (to within at least 1 ml) as the pycnometer and with a mass equal to the mass of the pycnometer filled with a liquid of specific gravity 1,01 (sodium chloride solution 2,0 % m/v).U.K.

A thermally insulated container, exactly fitting the body of the pycnometer.

4.1.3.A twin-pan balance with a range of at least 300 g and a sensitivity of 0,1 mg,U.K.

or

a single-pan balance with a range of at least 200 g and a sensitivity of 0,1 mg.

4.2.Calibration of pycnometerU.K.

Calibration of the pycnometer involves a determination of the following quantities:

  • tare of the empty pycnometer,

  • volume of the pycnometer at 20 °C,

  • mass of the water-filled pycnometer at 20 °C.

4.2.1. Method using a twin-pan balance U.K.

Place the tare bottle on the left-hand pan of the balance and the clean and dry pycnometer, fitted with its ‘reservoir stopper’, on the right-hand pan. Add weights to the pan holding the pycnometer and record the weight required to establish equilibrium: let it be p grams.

Carefully fill the pycnometer with distilled water at the ambient temperature and fit the thermometer; carefully wipe the pycnometer dry and place it in the thermally insulated container. Mix it by inverting the container until the temperature reading on the thermometer is constant. Accurately adjust the level to the upper rim of the side tube. Wipe the side tube dry and put the reservoir stopper on; read the temperature t °C carefully, possibly correcting it for the inaccuracy in the temperature scale. Weigh the water-filled pycnometer against the tare and record the weight p′ in grams required to establish equilibrium.

Calculation (2) : U.K.

Taring of empty pycnometer:

tare of empty pycnometer = p + m,

where m

=

mass of air contained in the pycnometer,

m

=

0,0012 (pp′).

Volume at 20 °C:

V 20 °C = (p + mp′) · Ft ,

where Ft

=

a factor taken from Table I for the temperature t °C.

V 20 °C should be known to within ± 0,001 ml.

Mass of water at 20 °C:

M 20 °C = 0,998203 V 20 °C,

where 0,998203 is the density of water at 20 °C.

4.2.2.Method using a single-pan balanceU.K.

Determine:

  • the mass of the clean and dry pycnometer: let this be P,

  • the mass of the pycnometer filled with water at t °C, following the procedure described in 4.2.1 above: let this be P 1,

  • the mass of the tare: T 0.

Calculation(2): U.K.

Taring of empty pycnometer:

tare of empty pycnometer = Pm,

where m

=

mass of air contained in the pycnometer,

m

=

0,0012 (P 1P).

Volume at 20 °C:

V 20 °C = [P 1 − (P − m)] × Ft

where Ft

=

a factor taken from Table I for the temperature t °C.

The volume at 20 °C should be known to within ± 0,001 ml.

Mass of water at 20 °C:

M 20 °C = 0,998203 V 20 °C,

where 0,998203 is the density of water at 20 °C.

4.3.Method of measurement(2) U.K.
4.3.1.Method using twin-pan balanceU.K.

Fill the pycnometer with the prepared test sample, following the procedure described in 4.2.1 above.

Let p″ be the weight in grams required to establish equilibrium at t °C.

Mass of liquid contained in the pycnometer = p + mp″.

Apparent density at t °C:

Calculate the density at 20 °C using one of the correction tables given later, in accordance with the nature of the liquid being measured: dry wine (Table II), natural or concentrated must (Table III), sweet wine (Table IV).

The 20 °C/20 °C specific gravity of the wine is calculated by dividing its density at 20 °C by 0,998203.

4.3.2.Method using a single-pan balance(3) U.K.

Weigh the tare bottle and let its mass be T.

Calculate dT = T 1T 0.

Mass of the empty pycnometer at the time of measurement = Pm + dT.

Weigh the pycnometer filled with the prepared test sample, following the procedure described in 4.2.1 above. Let its mass at t °C be P 2.

Mass of liquid contained in pycnometer at t °C = P 2 − (Pm + dT)

Apparent density at t °C:

Calculate the density at 20 °C of the liquid under test (dry wine, natural or concentrated must, or sweet wine) as indicated in 4.3.1 above.

The 20 °C/20 °C specific gravity is calculated by dividing the density at 20 °C by 0,998203.

4.3.3.The repeatability of the density measurementsU.K.
  • for dry and semi-sweet wines: r = 0,00010,

  • and for sweet wines: r = 0,00018.

4.3.4.The reproducibility of the density measurements:U.K.
  • for dry and semi-sweet wines: R = 0,00037,

  • and for sweet wines: R = 0,00045.

(1)

Any pycnometer with equivalent characteristics may be used.

(2)

A numeric example is given in section 6 of this chapter.

(3)

A numeric example is given in section 6 of this chapter.

Yn ôl i’r brig

Options/Cymorth

Print Options

You have chosen to open the Whole Regulation

The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

You have chosen to open Schedules only

Y Rhestrau you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

Gweler y wybodaeth ychwanegol ochr yn ochr â’r cynnwys

Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted version that was used for the EU Official Journal
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Llinell Amser Newidiadau

Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.

Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.

Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.

Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill