- Y Diweddaraf sydd Ar Gael (Diwygiedig)
- Pwynt Penodol mewn Amser (01/03/2014)
- Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE)
Commission Regulation (EEC) No 2568/91 of 11 July 1991 on the characteristics of olive oil and olive-residue oil and on the relevant methods of analysis
Pan adawodd y DU yr UE, cyhoeddodd legislation.gov.uk ddeddfwriaeth yr UE a gyhoeddwyd gan yr UE hyd at ddiwrnod cwblhau’r cyfnod gweithredu (31 Rhagfyr 2020 11.00 p.m.). Ar legislation.gov.uk, mae'r eitemau hyn o ddeddfwriaeth yn cael eu diweddaru'n gyson ag unrhyw ddiwygiadau a wnaed gan y DU ers hynny.
Mae legislation.gov.uk yn cyhoeddi fersiwn y DU. Mae EUR-Lex yn cyhoeddi fersiwn yr UE. Mae Archif Gwe Ymadael â’r UE yn rhoi cipolwg ar fersiwn EUR-Lex o ddiwrnod cwblhau’r cyfnod gweithredu (31 Rhagfyr 2020 11.00 p.m.).
Version Superseded: 16/10/2015
Point in time view as at 01/03/2014.
There are outstanding changes by UK legislation not yet made to Commission Regulation (EEC) No 2568/91. Any changes that have already been made to the legislation appear in the content and are referenced with annotations.
Changes and effects yet to be applied by the editorial team are only applicable when viewing the latest version or prospective version of legislation. They are therefore not accessible when viewing legislation as at a specific point in time. To view the ‘Changes to Legislation’ information for this provision return to the latest version view using the options provided in the ‘What Version’ box above.
Textual Amendments
The method describes a procedure for determining the individual and total sterols and triterpene dialcohols content of olive oils and olive-pomace oils.
The oil, with added α-cholestanol as an internal standard, is saponified with potassium hydroxide in ethanolic solution and the unsaponifiable matter is then extracted with ethyl ether.
The sterols and triterpene dialcohols fraction is separated from the unsaponifiable matter by thin-layer chromatography on a basic silica gel plate. The fractions recovered from the silica gel are transformed into trimethylsilyl ethers and then analysed by capillary column gas chromatography.
The usual laboratory equipment and in particular the following:
250 ml flask fitted with a reflux condenser with ground-glass joints.
500 ml separating funnel.
250 ml flasks.
Complete apparatus for analysis by thin-layer chromatography using 20 x 20 cm glass plates.
Ultraviolet lamp with a wavelength of 254 or 366 nm.
100 μl and 500 μl microsyringes.
Cylindrical filter funnel with a G3 porous septum (porosity 15-40 μm) of diameter approximately 2 cm and a depth of 5 cm, suitable for filtration under vacuum with male ground-glass joint.
50 ml vacuum conical flask with ground-glass female joint, which can be fitted to the filter funnel (point 3.7).
10 ml test tube with a tapering bottom and a sealing glass stopper.
Gas chromatograph suitable for use with a capillary column with split injection system, consisting of:
A thermostatic chamber for columns capable of maintaining the desired temperature with an accuracy of ± 1°C;
A temperature-adjustable injection unit with a persilanised glass vaporising element and split system;
A flame ionisation detector (FID);
Data acquisition system suitable for use with the FID detector (point 3.10.3.), capable of manual integration.
Fused-silica capillary column of length 20 to 30 m, internal diameter 0,25 to 0,32 mm, coated with 5 % diphenyl - 95 % dimethylpolysiloxane (SE-52 or SE-54 stationary phase or equivalent), to a uniform thickness between 0,10 and 0,30 μm.
Microsyringe, of 10 ml capacity, for gas chromatography, with cemented needle suitable for split injection.
Calcium dichloride desiccator
Dissolve 130 g of potassium hydroxide (point 4.1) with cooling in 200 ml of distilled water and then make up to one litre with ethanol (point 4.10). Keep the solution in well-stoppered dark glass bottles and stored maximum two days.
Dissolve 13 g of potassium hydroxide (point 4.1) in 20 ml of distilled water and make up to one litre with ethanol (point 4.10).
To be prepared at the time of use from sterols and erythrodiol obtained from oils containing them.
Then draw off the soap solution as completely as possible into a second separating funnel. Perform two further extractions on the water-alcohol phase in the same way using 60 to 70 ml of ethyl ether (point 4.10).
Note 2 : Any emulsion can be destroyed by adding small quantities of ethanol (point 4.11). U.K.
When the wash water has been removed, filter on anhydrous sodium sulphate (point 4.5) into a previously weighed 250 ml flask, washing the funnel and filter with small quantities of ethyl ether (point 4.10).
Remove from the oven and keep in a calcium chloride desiccator (point 3.13) until required for use (plates treated in this way must be used within 15 days).
Note 5 : Higher temperature could worsen the separation. U.K.
Wash the residue in the flask three times with ethyl ether (point 4.3) (approximately 10 ml each time), collecting the filtrate in the same flask attached to the funnel, evaporate the filtrate to a volume of 4 to 5 ml, transfer the residual solution to the previously weighed 10 ml test tube (point 3.9), evaporate to dryness by mild heating, in a gentle flow of nitrogen, make up again using a few drops of acetone (point 4.8), evaporate again to dryness,
The residue contained in the test tube must consist of the sterol and triterpene dialchols fractions.
Pyridine can be replaced by the same amount of acetonitrile.
Carry out general checks on the gas chromatograph unit (leaks from the gas circuits, detector efficiency, efficiency of the splitting system and recording system, etc.).
A negative straight-line drift indicates leakage from the column connections; a positive drift indicates inadequate conditioning of the column.
Column temperature: 260 ± 5 °C;
Injector temperature: 280-300 °C;
Detector temperature: 280-300 °C;
Linear velocity of the carrier gas: helium 20 to 35 cm/s; hydrogen 30 to 50 cm/s;
Splitting ratio: from 1:50 to 1:100;
Instrument sensitivity: from 4 to 16 times the minimum attenuation;
Recording sensitivity: 1 to 2 mV full scale;
Amount of substance injected: 0,5 to 1 μl of TMSE solution.
These conditions may be changed according to the characteristics of the column and gas chromatograph, so as to obtain chromatograms, which meet the following requirements:
The retention time for the ß-sitosterol peak should be at 20 ± 5 min;
The campesterol peak should be: for olive oil (mean content 3 %) 20 ± 5 % of full scale; for soybean oil (average content 20 %) 80 ± 10 % of full scale;
All the present sterols must be separated. In addition to being separated the peaks, they must also be completely resolved, i.e. the peak trace should return to the base line before leaving for the next peak. Incomplete resolution is, however, tolerated, provided that the peak at RRT 1,02 (Sitostanol) can be quantified using the perpendicular.
An automatic injector can be used as well.
Identify individual peaks on the basis of retention times and by comparison with the mixture of sterol and triterpene dialcohols TMSE, analysed under the same conditions (see Appendix).
The sterols and triterpene dialcohols are eluted in the following order: cholesterol, brassicasterol, ergosterol, 24-methylen-cholesterol, campesterol, campestanol, stigmasterol, Δ7-campesterol, Δ5,23-stigmastadienol, clerosterol, ß-sistosterol, sitostanol, Δ5-avenasterol, Δ5,24-stigmastadienol, Δ7-stigmastenol, Δ7-avenasterol, erythrodiol and uvaol.
The retention times for ß-sitosterol, for SE-52 and SE-54 columns, are shown in Table 1.
Figures 1 and 2 show typical chromatograms for some oils.
where:
=
peak area for sterol x, in computing system counts;
=
area of the α-cholestanol peak, in computing system counts;
=
mass of added α-cholestanol, in milligrams;
=
mass of the sample used for determination, in grams.
The composition of each of the individual sterols and of the erythrodiol and uvaol should be expressed to one decimal point.
Total sterol composition must be expressed without any decimal point.
where:
=
peak area for x;
=
total peak area for sterols;
where
=
sum area for sterol in computing system counts;
=
area of Erythrodiol in computing system counts;
=
area of Uvaol in computing system counts;
With the gas chromatograph set to normal operating conditions, inject 1 to 3 μl of methane (or propane) and measure the time taken by the gas to pass through the column, from the time of injection to the time at which the peak appears (tM).
The linear speed in cm/s is given by L/tM, where L is the length of the column in centimetres and tM is the measured time, in seconds.
Relative retention times for sterols
Peak | Identification | Relative retention time | ||
---|---|---|---|---|
SE 54 column | SE 52 column | |||
1 | Cholesterol | Δ-5-cholesten-3 ß -ol | 0,67 | 0,63 |
2 | Cholestanol | 5 α -cholestan-3 ß -ol | 0,68 | 0,64 |
3 | Brassicasterol | [24S]-24-methyl-Δ-5,22-cholestadien-3 ß -ol | 0,73 | 0,71 |
* | Ergosterol | [24S] 24 methy Δ5-7-22 cholestatrien 3ß-ol | 0,78 | 0,76 |
4 | 24-methylene-cholesterol | 24-methylene-Δ-5,24-cholestadien-3 ß -o1 | 0,82 | 0,8 |
5 | Campesterol | (24R)-24-methyl-Δ-5-cholesten-3 ß -ol | 0,83 | 0,81 |
6 | Campestanol | (24R)-24-methyl-cholestan-3 ß -ol | 0,85 | 0,82 |
7 | Stigmasterol | (24S)-24-ethyl-Δ-5,22-cholestadien-3 ß -ol | 0,88 | 0,87 |
8 | Δ-7-campesterol | (24R)-24-methyl-Δ-7-cholesten-3 ß -ol | 0,93 | 0,92 |
9 | Δ-5,23-stigmastadienol | (24R,S)-24-ethyl-Δ-5,23-choIestadien-3 ß -ol | 0,95 | 0,95 |
10 | Clerosterol | (24S)-24-ethyl-Δ-5,25-cholestadien-3 ß -ol | 0,96 | 0,96 |
11 | ß -sitosterol | (24R)-24-ethyl-Δ-5-cholesten-3 ß -ol | 1,0 | 1,0 |
12 | Sitostanol | 24-ethyl-cholestan-3 ß -ol | 1,02 | 1,02 |
13 | Δ-5-avenasterol | (24Z)-24-ethylidene-Δ-cholesten-3 ß -ol | 1,03 | 1,03 |
14 | Δ-5-24-stigmastadienol | (24R,S)-24-ethyl-Δ-5,24-cholestadien-3 ß -ol | 1,08 | 1,08 |
15 | Δ-7-stigmastenol | (24R,S)-24-ethyl-Δ-7-cholesten-3 ß -ol | 1,12 | 1,12 |
16 | Δ-7-avenasterol | (24Z)-24-ethylidene-Δ-7-cholesten-3 ß -ol | 1,16 | 1,16 |
17 | Erythrodiol | 5α olean-12en-3ß28 diol | 1,41 | 1,41 |
18 | Uvaol | Δ12-ursen-3ß28 diol | 1,52 | 1,52 |
Figure 1
Gas chromatogram of the sterol and triterpene dialchols fraction of a lampante olive oil (spiked with internal standard)
The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Y Rhestrau you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys