- Y Diweddaraf sydd Ar Gael (Diwygiedig)
- Pwynt Penodol mewn Amser (13/03/2010)
- Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE)
Commission Regulation (EC) No 401/2006 of 23 February 2006 laying down the methods of sampling and analysis for the official control of the levels of mycotoxins in foodstuffs (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3
Version Superseded: 01/07/2014
Point in time view as at 13/03/2010.
There are currently no known outstanding effects for the Commission Regulation (EC) No 401/2006, ANNEX I .
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
Official controls shall be performed in accordance with the provisions of Regulation (EC) No 882/2004. The following general provisions shall apply without prejudice to the provisions in Regulation (EC) No 882/2004.
Samples intended for official control of the levels of mycotoxins content in foodstuffs shall be taken according to the methods set out in this Annex. Aggregate samples thus obtained shall be considered as representative of the lots. Compliance with maximum limits laid down in Regulation (EC) No 466/2001 shall be established on the basis of the levels determined in the laboratory samples.
For the purpose of this Annex, the following definitions shall apply:
‘lot’ means an identifiable quantity of a food commodity delivered at one time and determined by the official to have common characteristics, such as origin, variety, type of packing, packer, consignor or markings;
‘sublot’ means a designated part of a large lot in order to apply the sampling method on that designated part; each sublot must be physically separate and identifiable;
‘incremental sample’ means a quantity of material taken from a single place in the lot or sublot;
‘aggregate sample’ means the combined total of all the incremental samples taken from the lot or sublot;
‘laboratory sample’ means a sample intended for the laboratory.
Sampling shall be performed by an authorised person as designated by the Member State.
Each lot which is to be examined shall be sampled separately. In accordance with the specific sampling provisions for the different mycotoxins, large lots shall be subdivided into sublots to be sampled separately.
In the course of sampling and preparation of the samples, precautions shall be taken to avoid any changes, which would affect:
the mycotoxin content, adversely affect the analytical determination or make the aggregate samples unrepresentative;
the food safety of the lots to be sampled.
Also, all measures necessary to ensure the safety of the persons taking the samples shall be taken.
As far as possible incremental samples shall be taken at various places distributed throughout the lot or sublot. Departure from such procedure shall be recorded in the record provided for under part A.3.8. of this Annex I.
The aggregate sample shall be made up by combining the incremental samples.
The replicate samples for enforcement, trade (defence) and reference (referee) purposes shall be taken from the homogenised aggregate sample, unless such procedure conflicts with Member States’ rules as regards the rights of the food business operator.
Each sample shall be placed in a clean, inert container offering adequate protection from contamination and against damage in transit. All necessary precautions shall be taken to avoid any change in composition of the sample, which might arise during transportation or storage.
Each sample taken for official use shall be sealed at the place of sampling and identified following the rules of the Member State.
A record shall be kept of each sampling, permitting each lot to be identified unambiguously and giving the date and place of sampling together with any additional information likely to be of assistance to the analyst.
Food commodities may be traded in bulk, containers, or individual packings, such as sacks, bags, retail packings. The method of sampling may be applied to all the different forms in which the commodities are put on the market.
Without prejudice to the specific provisions set out in other parts of this Annex, the following formula may be used as a guide for the sampling of lots traded in individual packs, such as sacks, bags, retail packings.
weight: in kg
sampling frequency (SF): every nth sack or bag from which an incremental sample must be taken (decimal figures should be rounded to the nearest whole number).
This method of sampling is of application for the official control of the maximum levels established for aflatoxin B1, total aflatoxins, ochratoxin A and Fusarium-toxins in cereals and cereal products.
The weight of the incremental sample shall be about 100 grams, unless otherwise defined in this part B of Annex I.
In the case of lots in retail packings, the weight of the incremental sample shall depend on the weight of the retail pack.
In the case of retail packs of more than 100 grams, this will result in aggregate samples weighing more than 10 kg. If the weight of a single retail pack is much more than 100 grams, then 100 grams shall be taken from each individual retail pack as an incremental sample. This can be done either when the sample is taken or in the laboratory. However, in cases where such method of sampling would lead to unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.), then an alternative method of sampling can be applied. For example, in case where a valuable product is marketed in retail packs of 500 grams or 1 kg, the aggregate sample can be obtained by the aggregation of a number of incremental samples that is smaller than the number indicated in Tables 1 and 2, on the condition that the weight of the aggregate sample is equal to the required weight of the aggregate sample mentioned in Tables 1 and 2.
Where the retail pack is less than 100 grams and if the difference is not very large, one retail pack is to be considered as one incremental sample, resulting in an aggregate sample of less than 10 kg. If the weight of the retail pack is much less than 100 grams, one incremental sample consists of two or more retail packs, whereby the 100 grams are approximated as closely as possible.
Subdivision of lots into sublots depending on product and lot weight
a Depending on the lot weight — see Table 2. | ||||
Commodity | Lot weight (tonnes) | Weight or number of sublots | Number of incremental samples | Aggregate sample weight (kg) |
---|---|---|---|---|
Cereals and cereal products | ≥ 1 500 | 500 tonnes | 100 | 10 |
> 300 and < 1 500 | 3 sublots | 100 | 10 | |
≥ 50 and ≤ 300 | 100 tonnes | 100 | 10 | |
< 50 | — | 3-100a | 1-10 |
On condition that the sublot can be separated physically, each lot shall be subdivided into sublots following Table 1. Taking into account that the weight of the lot is not always an exact multiple of the weight of the sublots, the weight of the sublot may exceed the mentioned weight by a maximum of 20 %. In case the lot is not or cannot be physically separated into sublots, a minimum of 100 incremental samples is taken from the lot.
Each sublot shall be sampled separately.
Number of incremental samples: 100. Weight of the aggregate sample = 10 kg.
If it is not possible to carry out the method of sampling set out in this point because of the unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented. An alternative method of sampling may also be applied in cases where it is practically impossible to apply the abovementioned method of sampling. This is e.g. the case where large lots of cereals are stored in warehouses or where cereals are stored in silos(3).
For lots of cereals and cereal products less than 50 tonnes, the sampling plan shall be used with 10 to 100 incremental samples, depending on the lot weight, resulting in an aggregate sample of 1 to 10 kg. For very small lots (≤ 0,5 tonnes) a lower number of incremental samples may be taken, but the aggregate sample combining all incremental samples shall be also in that case at least 1 kg.
The figures in Table 2 may be used to determine the number of incremental samples to be taken.
Number of incremental samples to be taken depending on the weight of the lot of cereals and cereal products
Lot weight (tonnes) | Number of incremental samples | Aggregate sample weight(kg) |
---|---|---|
≤ 0,05 | 3 | 1 |
> 0,05-≤ 0,5 | 5 | 1 |
> 0,5-≤ 1 | 10 | 1 |
> 1-≤ 3 | 20 | 2 |
> 3-≤ 10 | 40 | 4 |
> 10-≤ 20 | 60 | 6 |
> 20-≤ 50 | 100 | 10 |
Sampling of foodstuffs at the retail stage must be done where possible in accordance with the provisions set out in this part B of Annex I.
Where that is not possible, an alternative method of sampling at retail stage may be applied provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 1 kg(4).
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty;
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.
This method of sampling is of application for the official control of the maximum levels established for:
aflatoxin B1 and total aflatoxins in dried fruit but with the exception of dried figs and
ochratoxin A in dried vine fruit (currants, raisins and sultanas).
The weight of the incremental sample shall be about 100 grams, unless otherwise defined in this part C of Annex I.
In the case of lots in retail packings, the weight of the incremental sample depends on the weight of the retail packing.
In the case of retail packs of more than 100 grams, this will result in aggregate samples weighing more than 10 kg. If the weight of a single retail pack is much more than 100 grams, then 100 grams shall be taken from each individual retail pack as an incremental sample. This can be done either when the sample is taken or in the laboratory. However, in cases where such method of sampling would lead to unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) then an alternative method of sampling can be applied. For example, in case where a valuable product is marketed in retail packs of 500 grams or 1 kg, the aggregate sample can be obtained by the aggregation of a number of incremental samples that is smaller than the number indicated in Tables 1 and 2, on the condition that the weight of the aggregate sample corresponds to the required weight of the aggregate sample mentioned in Tables 1 and 2.
Where the retail pack is less than 100 grams and if the difference is not very large, one retail pack shall be considered as one incremental sample, resulting in an aggregate sample of less than 10 kg. If the weight of the retail pack is much less than 100 grams, one incremental sample shall consist of two or more retail packs, whereby the 100 grams are approximated as closely as possible.
Subdivision of lots into sublots depending on product and lot weight
a Depending on the lot weight — see Table 2 of this part of this Annex. | ||||
Commodity | Lot weight (tonnes) | Weight or number of sublots | Number of incremental samples | Aggregate sample weight (kg) |
---|---|---|---|---|
Dried fruit | ≥ 15 | 15-30 tonnes | 100 | 10 |
< 15 | — | 10-100a | 1-10 |
On condition that the sublot can be separated physically, each lot shall be subdivided into sublots following Table 1. Taking into account that the weight of the lot is not always an exact multiple of the weight of the sublots, the weight of the sublot may exceed the mentioned weight by a maximum of 20 %.
Each sublot shall be sampled separately.
Number of incremental samples: 100. Weight of the aggregate sample = 10 kg.
If it is not possible to carry out the method of sampling described above because of the commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
For dried fruit lots, with the exception of figs, under 15 tonnes the sampling plan shall be used with 10 to 100 incremental samples, depending on the lot weight, resulting in an aggregate sample of 1 to 10 kg.
The figures in the following table can be used to determine the number of incremental samples to be taken.
Number of incremental samples to be taken depending on the weight of the lot of dried fruit
Lot weight (tonnes) | Number of incremental samples | Aggregate sample weight (kg) |
---|---|---|
≤ 0,1 | 10 | 1 |
> 0,1-≤ 0,2 | 15 | 1,5 |
> 0,2-≤ 0,5 | 20 | 2 |
> 0,5-≤ 1,0 | 30 | 3 |
> 1,0-≤ 2,0 | 40 | 4 |
> 2,0-≤ 5,0 | 60 | 6 |
> 5,0-≤ 10,0 | 80 | 8 |
> 10,0-≤ 15,0 | 100 | 10 |
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I.
Where that is not possible, another alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 1 kg(5).
For lots equal to or more than 15 tonnes at least 25 incremental samples resulting in a 10 kg aggregate sample shall be taken and for lots less than 15 tonnes, 25 % of the number of incremental samples mentioned in Table 2 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see Table 2).
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty;
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.
This method of sampling is of application for the official control of the maximum levels established for aflatoxin B1 and total aflatoxins in dried figs, groundnuts and nuts.
This method of sampling is of application for the official control of the maximum levels established for aflatoxin B1 and total aflatoxins in dried figs.
The weight of the incremental sample shall be about 300 grams, unless otherwise defined in part D.1 of Annex I.
In the case of lots in retail packings, the weight of the incremental sample depends on the weight of the retail packing.
In the case of retail packs of more than 300 grams, this will result in aggregate samples weighing more than 30 kg. If the weight of a single retail pack is much more than 300 grams, then 300 grams shall be taken from each individual retail pack as an incremental sample. This can be done either when the sample is taken or in the laboratory. However, in cases where such method of sampling would lead to unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.), then an alternative method of sampling can be applied. For example, in case where a valuable product is marketed in retail packs of 500 grams or 1 kg, the aggregate sample can be obtained by the aggregation of a number of incremental samples that is smaller than the number indicated in tables 1, 2 and 3, on the condition that the weight of the aggregate sample corresponds to the required weight of the aggregate sample mentioned in tables 1, 2 and 3.
Where the retail pack is less than 300 grams and if the difference is not very large, one retail pack shall be considered as one incremental sample, resulting in an aggregate sample of less than 30 kg. If the weight of the retail pack is much less than 300 grams, one incremental sample shall consist of two or more retail packs, whereby the 300 grams are approximated as closely as possible.
Subdivision of lots into sublots depending on product and lot weight
a Depending on the lot weight — see table 2 of this part D.1 of this Annex. | ||||
Commodity | Lot weight (tonne) | Weight or number of sublots | No incremental samples | Aggregate sample weight (kg) |
---|---|---|---|---|
Dried figs | ≥ 15 | 15-30 tonnes | 100 | 30 |
< 15 | — | 10-100 a | ≤ 30 |
On condition that the sublot can be separated physically, each lot shall be subdivided into sublots following table 1. Taking into account that the weight of the lot is not always an exact multiple of the weight of the sublots, the weight of the sublot may exceed the mentioned weight by a maximum of 20 %.
Each sublot shall be sampled separately,
Number of incremental samples: 100,
Weight of the aggregate sample = 30 kg which shall be mixed and to be divided into three equal laboratory samples of 10 kg before grinding (this division into three laboratory samples is not necessary in case of dried figs subjected to further sorting or other physical treatment and of the availability of equipment which is able to homogenise a 30 kg sample).
Each laboratory sample of 10 kg shall be separately ground finely and mixed thoroughly to achieve complete homogenisation, in accordance with the provisions laid down in Annex II,
If it is not possible to carry out the method of sampling described above because of the unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
The number of incremental samples to be taken depends on the weight of the lot, with a minimum of 10 and a maximum of 100.
The figures in the following table 2 may be used to determine the number of incremental samples to be taken and the subsequent division of the aggregate sample.
Number of incremental samples to be taken depending on the weight of the lot and number of subdivisions of the aggregate sample
Lot weight (tonnes) | No of incremental samples | Aggregate sample Weight (kg) (in case of retail packings, weight of aggregate sample can diverge — see point D.1.1) | No of laboratory samples from aggregate sample |
---|---|---|---|
≤ 0,1 | 10 | 3 | 1 (no division) |
> 0,1 – ≤ 0,2 | 15 | 4,5 | 1 (no division) |
> 0,2 – ≤ 0,5 | 20 | 6 | 1 (no division) |
> 0,5 – ≤ 1,0 | 30 | 9 (- < 12 kg) | 1 (no division) |
> 1,0 – ≤ 2,0 | 40 | 12 | 2 |
> 2,0 – ≤ 5,0 | 60 | 18 (- < 24 kg) | 2 |
> 5,0 – ≤ 10,0 | 80 | 24 | 3 |
> 10,0 – ≤ 15,0 | 100 | 30 | 3 |
Weight of the aggregate sample ≤ 30 kg which shall be mixed and divided into two or three equal laboratory samples of ≤ 10 kg before grinding (this division into two or three laboratory samples is not necessary in case of dried figs, subjected to further sorting or other physical treatment and of the availability of equipment which is able to homogenise up to 30 kg samples).
In cases where the aggregate sample weights are less than 30 kg, the aggregate sample shall be divided into laboratory samples according to following guidance:
< 12 kg: no division into laboratory samples;
≥ 12 – < 24 kg: division into two laboratory samples;
≥ 24 kg: division into three laboratory samples.
Each laboratory sample shall be separately ground finely and mixed thoroughly to achieve complete homogenisation, in accordance with the provisions laid down in Annex II,
If it is not possible to carry out the method of sampling described above because of the unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
Number of incremental samples: 100; for lots of under 50 tons the number of incremental samples shall be 10 to 100, depending on the lot weight (see table 3),
Table 3 | ||
Number of incremental samples to be taken depending on the weight of the lot | ||
Lot weight (tonnes) | No of incremental samples | Aggregate sample weight (kg) |
---|---|---|
≤ 1 | 10 | 1 |
> 1 – ≤ 3 | 20 | 2 |
> 3 – ≤ 10 | 40 | 4 |
> 10 – ≤ 20 | 60 | 6 |
> 20 – ≤ 50 | 100 | 10 |
The weight of the incremental sample shall be about 100 grams. In the case of lots in retail packing, the weight of the incremental sample depends on the weight of the retail packing,
Weight of aggregate sample = 1-10 kg sufficiently mixed,
Method of sampling and acceptance as for dried figs (D.1.3 and D.1.4).
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I.
Where that is not possible, other effective methods of sampling at retail stage may be used provided that they ensure that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 1 kg (6) .
For lots equal to or more than 15 tonnes at least 50 incremental samples resulting in a 30 kg aggregate sample shall be taken and for lots of less than 15 tonnes, 50 % of the number of incremental samples mentioned in table 2 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see table 2).
For lots equal to or more than 50 tonnes at least 25 incremental samples resulting in a 10 kg aggregate sample shall be taken and for lots less than 50 tonnes, 25 % of the number of incremental samples mentioned in table 3 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see table 3).
For dried figs subjected to a sorting or other physical treatment:
acceptance if the aggregate sample or the average of the laboratory samples conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the aggregate sample or the average of the laboratory samples exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty,
For dried figs intended for direct human consumption:
acceptance if none of the laboratory samples exceeds the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if one or more of the laboratory samples exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty,
In cases where the aggregate sample is 12 kg or less:
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty,
Textual Amendments
This method of sampling is of application for the official control of the maximum levels established for aflatoxin B1 and total aflatoxins in groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts.
The weight of the incremental sample shall be about 200 grams, unless otherwise defined in part D.2 of Annex I.
In the case of lots in retail packings, the weight of the incremental sample depends on the weight of the retail packing.
In the case of retail packs of more than 200 grams, this will result in aggregate samples weighing more than 20 kg. If the weight of a single retail pack is much more than 200 grams, then 200 grams shall be taken from each individual retail pack as an incremental sample. This can be done either when the sample is taken or in the laboratory. However, in cases where such method of sampling would lead to unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.), then an alternative method of sampling can be applied. For example, in case where a valuable product is marketed in retail packs of 500 grams or 1 kg, the aggregate sample can be obtained by the aggregation of a number of incremental samples that is smaller than the number indicated in tables 1, 2 and 3, on the condition that the weight of the aggregate sample corresponds to the required weight of the aggregate sample mentioned in tables 1, 2 and 3.
Where the retail pack is less than 200 grams and if the difference is not very large, one retail pack shall be considered as one incremental sample, resulting in an aggregate sample of less than 20 kg. If the weight of the retail pack is much less than 200 grams, one incremental sample shall consist of two or more retail packs, whereby the 200 grams are approximated as closely as possible.
Subdivision of lots into sublots depending on product and lot weight
a Depending on the lot weight — see table 2 of this part D.2 of this Annex. | ||||
Commodity | Lot weight (tonne) | Weight or number of sublots | No incremental samples | Aggregate sample weight (kg) |
---|---|---|---|---|
Groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts | ≥ 500 | 100 tonnes | 100 | 20 |
> 125 and < 500 | 5 sublots | 100 | 20 | |
≥ 15 and ≤ 125 | 25 tonnes | 100 | 20 | |
< 15 | — | 10-100 a | ≤ 20 |
On condition that the sublot can be separated physically, each lot shall be subdivided into sublots following table 1. Taking into account that the weight of the lot is not always an exact multiple of the weight of the sublots, the weight of the sublot may exceed the mentioned weight by a maximum of 20 %.
Each sublot shall be sampled separately,
Number of incremental samples: 100,
Weight of the aggregate sample = 20 kg which shall be mixed and to be divided into two equal laboratory samples of 10 kg before grinding (this division into two laboratory samples is not necessary in case of groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts subjected to further sorting or other physical treatment and of the availability of equipment which is able to homogenise a 20 kg sample).
Each laboratory sample of 10 kg shall be separately ground finely and mixed thoroughly to achieve complete homogenisation, in accordance with the provisions laid down in Annex II,
If it is not possible to carry out the method of sampling described above because of the commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
The number of incremental samples to be taken depends on the weight of the lot, with a minimum of 10 and a maximum of 100.
The figures in the following table 2 may be used to determine the number of incremental samples to be taken and the subsequent division of the aggregate sample.
Number of incremental samples to be taken depending on the weight of the lot and number of subdivisions of the aggregate sample
Lot weight (tonnes) | No of incremental samples | Aggregate sample Weight (kg) (in case of retail packings, weight of aggregate sample can diverge — see point D.2.1) | No of laboratory samples from aggregate sample |
---|---|---|---|
≤ 0,1 | 10 | 2 | 1 (no division) |
> 0,1 – ≤ 0,2 | 15 | 3 | 1 (no division) |
> 0,2 – ≤ 0,5 | 20 | 4 | 1 (no division) |
> 0,5 – ≤ 1,0 | 30 | 6 | 1 (no division) |
> 1,0 – ≤ 2,0 | 40 | 8 (- < 12 kg) | 1 (no division) |
> 2,0 – ≤ 5,0 | 60 | 12 | 2 |
> 5,0 – ≤ 10,0 | 80 | 16 | 2 |
> 10,0 – ≤ 15,0 | 100 | 20 | 2 |
Weight of the aggregate sample ≤ 20 kg which shall be mixed and if necessary divided into two equal laboratory samples of ≤ 10 kg before grinding (this division into two laboratory samples is not necessary in case of, groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts subjected to further sorting or other physical treatment and of the availability of equipment which is able to homogenise up to 20 kg samples).
In cases where the aggregate sample weights are less than 20 kg, the aggregate sample shall be divided into laboratory samples according to following guidance:
< 12 kg: no division into laboratory samples;
≥ 12 kg division into two laboratory samples.
Each laboratory sample shall be separately ground finely and mixed thoroughly to achieve complete homogenisation, in accordance with the provisions laid down in Annex II,
If it is not possible to carry out the method of sampling described above because of the unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
Number of incremental samples: 100; for lots of under 50 tons the number of incremental samples shall be 10 to 100, depending on the lot weight (see table 3),
Table 3 | ||
Number of incremental samples to be taken depending on the weight of the lot | ||
Lot weight (tonnes) | No of incremental samples | Aggregate sample weight (kg) |
---|---|---|
≤ 1 | 10 | 1 |
> 1 – ≤ 3 | 20 | 2 |
> 3 – ≤ 10 | 40 | 4 |
> 10 – ≤ 20 | 60 | 6 |
> 20 – ≤ 50 | 100 | 10 |
The weight of the incremental sample shall be about 100 grams. In the case of lots in retail packing, the weight of the incremental sample depends on the weight of the retail packing,
Weight of aggregate sample = 1-10 kg sufficiently mixed,
Method of sampling and acceptance as for groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts (D.2.3 and D.2.4).
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I.
Where that is not possible, other effective methods of sampling at retail stage may be used provided that they ensure that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 1 kg (1) .
For lots equal to or more than 15 tonnes at least 50 incremental samples resulting in a 20 kg aggregate sample shall be taken and for lots of less than 15 tonnes, 50 % of the number of incremental samples mentioned in table 2 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see table 2).
For lots equal to or more than 15 tonnes at least 25 incremental samples resulting in a 20 kg aggregate sample shall be taken and for lots less than 15 tonnes, 25 % of the number of incremental samples mentioned in table 2 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see table 2).
For lots equal to or more than 50 tonnes at least 25 incremental samples resulting in a 10 kg aggregate sample shall be taken and for lots less than 50 tonnes, 25 % of the number of incremental samples mentioned in table 3 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see table 3).
For groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts subjected to a sorting or other physical treatment:
acceptance if the aggregate sample or the average of the laboratory samples conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the aggregate sample or the average of the laboratory samples exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty,
For groundnuts (peanuts), other oilseeds, apricot kernels and tree nuts intended for direct human consumption:
acceptance if none of the laboratory samples exceeds the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if one or both of the laboratory samples exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty,
In cases where the aggregate sample is 12 kg or less:
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.]
[F1This method of sampling is of application for the official control of the maximum levels established for ochratoxin A, aflatoxin B1 and total aflatoxins in spices.]
The weight of the incremental sample shall be about 100 grams, unless otherwise defined in this part E of Annex I.
In the case of lots in retail packings, the weight of the incremental sample depends on the weight of the retail packing.
In the case of retail packs of >100 grams, this will result in aggregate samples weighing more than 10 kg. If the weight of a single retail pack is >> 100 grams, then 100 grams shall be taken from each individual retail pack as an incremental sample. This can be done either when the sample is taken or in the laboratory. However, in cases where such method of sampling would lead to unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.), then an alternative method of sampling can be applied. For example, in case where a valuable product is marketed in retail packs of 500 grams or 1 kg, the aggregate sample can be obtained by the aggregation of a number of incremental samples that is smaller than the number indicated in Tables 1 and 2, on the condition that the weight of the aggregate sample corresponds to the required weight of the aggregate sample mentioned in Tables 1 and 2.
Where the retail pack is less than 100 grams and if the difference is not very large, one retail pack shall be considered as one incremental sample, resulting in an aggregate sample of less than 10 kg. If the weight of the retail pack is much less than 100 grams, one incremental sample shall consist of two or more retail packs, whereby the 100 grams are approximated as closely as possible.
Subdivision of lots into sublots depending on product and lot weight
a Depending on the lot weight — see Table 2 of this part of this Annex. | ||||
Commodity | Lot weight (tonnes) | Weight or number of sublots | Number of incremental samples | Aggregate sample Weight (kg) |
---|---|---|---|---|
Spices | ≥ 15 | 25 tonnes | 100 | 10 |
< 15 | — | 5-100a | 0,5-10 |
On condition that the sublot can be separated physically, each lot shall be subdivided into sublots following Table 1. Taking into account that the weight of the lot is not always an exact multiple of the weight of the sublots, the weight of the sublot may exceed the mentioned weight by a maximum of 20 %.
Each sublot shall be sampled separately.
Number of incremental samples: 100. Weight of the aggregate sample = 10 kg.
If it is not possible to carry out the method of sampling described above because of the unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
For lots of spices less than 15 tonnes the sampling plan shall be used with 5 to 100 incremental samples, depending on the lot weight, resulting in an aggregate sample of 0,5 to 10 kg.
The figures in the following Table can be used to determine the number of incremental samples to be taken.
Number of incremental samples to be taken depending on the weight of the lot of spices
Lot weight (tonnes) | Number of incremental samples | Aggregate sample weight (kg) |
---|---|---|
≤ 0,01 | 5 | 0,5 |
> 0,01-≤ 0,1 | 10 | 1 |
> 0,1-≤ 0,2 | 15 | 1,5 |
> 0,2-≤ 0,5 | 20 | 2 |
> 0,5-≤ 1,0 | 30 | 3 |
> 1,0-≤ 2,0 | 40 | 4 |
> 2,0-≤ 5,0 | 60 | 6 |
> 5,0-≤ 10,0 | 80 | 8 |
> 10,0-≤ 15,0 | 100 | 10 |
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the sampling provisions set out in this part of Annex I.
Where that is not possible, an alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 0,5 kg(7).
For lots equal to or more than 15 tonnes at least 25 incremental samples resulting in a 10 kg aggregate sample shall be taken and for lots less than 15 tonnes, 25 % of the number of incremental samples mentioned in Table 2 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see Table 2).
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty;
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.
This method of sampling is of application for the official control of the maximum levels established for aflatoxin M1 in milk and milk products and infant formulae and follow-on formulae, including infant milk and follow-on milk and dietary foods (milk and milk products) for special medical purposes intended specifically for infants.
The aggregate sample shall be at least 1 kg or 1 litre except where it is not possible e.g. when the sample consists of one bottle.
The minimum number of incremental samples to be taken from the lot shall be as given in Table 1. The number of incremental samples determined is function of the usual form in which the products concerned are commercialised. In the case of bulk liquid products the lot shall be thoroughly mixed insofar as possible and insofar it does not affect the quality of the product, by either manual or mechanical means immediately prior to sampling. In this case, a homogeneous distribution of aflatoxin M1 is assumed within a given lot. It is therefore sufficient to take three incremental samples from a lot to form the aggregate sample.
The incremental samples, which might frequently be a bottle or a package, shall be of similar weight. The weight of an incremental sample shall be at least 100 grams, resulting in an aggregate sample of at least about 1 kg or 1 litre. Departure from this method shall be recorded in the record provided for under part A.3.8 of Annex I.
Minimum number of incremental samples to be taken from the lot
Form of commercialisation | Volume or weight of lot (in litre or kg) | Minimum number of incremental samples to be taken | Minimum volume or weight of aggregate sample (in litre or kg) |
---|---|---|---|
Bulk | — | 3-5 | 1 |
Bottles/packages | ≤ 50 | 3 | 1 |
Bottles/packages | 50 to 500 | 5 | 1 |
Bottles/packages | > 500 | 10 | 1 |
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I.
Where that is not possible, an alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented(8).
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty (or decision limit — see Annex II, point 4.4.),
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty (or decision limit — see Annex II, point 4.4.).
This method of sampling is of application for the official control of the maximum levels established for ochratoxin A in roasted coffee beans, ground roasted coffee, soluble coffee, liquorice root and liquorice extract.
The weight of the incremental sample shall be about 100 grams, unless otherwise defined in this part G of Annex I.
In the case of lots in retail packings, the weight of the incremental sample shall depend on the weight of the retail packing.
In the case of retail packs of more than 100 grams, this will result in aggregate samples weighing more than 10 kg. If the weight of a single retail pack is much more than 100 grams, then 100 grams shall be taken from each individual retail pack as an incremental sample. This can be done either when the sample is taken or in the laboratory. However, in cases where such method of sampling would lead to unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.), then an alternative method of sampling can be applied. For example, in case where a valuable product is marketed in retail packs of 500 grams or 1 kg, the aggregate sample can be obtained by the aggregation of a number of incremental samples that is smaller than the number indicated in tables 1 and 2, on the condition that the weight of the aggregate sample corresponds to the required weight of the aggregate sample mentioned in tables 1 and 2.
Where the retail pack is less than 100 grams and if the difference is not very large, one retail pack shall be considered as one incremental sample, resulting in an aggregate sample of less than 10 kg. If the weight of the retail pack is much less than 100 grams, one incremental sample shall consist of two or more retail packs, whereby the 100 grams are approximated as closely as possible.
Subdivision of lots into sublots depending on product and lot weight
a Depending on the lot weight — see table 2 of this part of this Annex. | ||||
Commodity | Lot weight (ton) | Weight or number of sublots | No incremental samples | Aggregate sample Weight (kg) |
---|---|---|---|---|
Roasted coffee beans, ground roasted coffee, soluble coffee, liquorice root and liquorice extract | ≥ 15 | 15-30 tonnes | 100 | 10 |
< 15 | — | 10-100 a | 1-10 |
On condition that the sublot can be separated physically, each lot shall be subdivided into sublots following table 1. Taking into account that the weight of the lot is not always an exact multiple of the weight of the sublots, the weight of the sublot may vary from the mentioned weight by a maximum of 20 %.
Each sublot shall be sampled separately,
Number of incremental samples: 100,
Weight of the aggregate sample = 10 kg,
If it is not possible to carry out the method of sampling described above because of the unacceptable commercial consequences resulting from damage to the lot (because of packaging forms, means of transport, etc.) an alternative method of sampling may be applied provided that it is as representative as possible and is fully described and documented.
For roasted coffee beans, ground roasted coffee, soluble coffee, liquorice root and liquorice extract under 15 tonnes the sampling plan shall be used with 10 to 100 incremental samples, depending on the lot weight, resulting in an aggregate sample of 1 to 10 kg.
The figures in the following table can be used to determine the number of incremental samples to be taken.
Number of incremental samples to be taken depending on the weight of the lot of roasted coffee beans, ground roasted coffee, soluble coffee, liquorice root and liquorice extract
Lot weight (tonnes) | No of incremental samples | Aggregate sample weight (kg) |
---|---|---|
≤ 0,1 | 10 | 1 |
> 0,1 – ≤ 0,2 | 15 | 1,5 |
> 0,2 – ≤ 0,5 | 20 | 2 |
> 0,5 – ≤ 1,0 | 30 | 3 |
> 1,0 – ≤ 2,0 | 40 | 4 |
> 2,0 – ≤ 5,0 | 60 | 6 |
> 5,0 – ≤ 10,0 | 80 | 8 |
> 10,0 – ≤ 15,0 | 100 | 10 |
For lots equal to or more than 15 tonnes at least 25 incremental samples resulting in a 10 kg aggregate sample shall be taken and for lots less than 15 tonnes, 25 % of the number of incremental samples mentioned in table 2 shall be taken resulting in an aggregate sample of which the weight corresponds to the weight of the sampled lot (see table 2).
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the sampling provisions set out in this part of Annex I.
Where that is not possible, an alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 1 kg (9) .
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.]
This method of sampling is of application for the official control of the maximum levels established for
ochratoxin A in wine, grape juice and grape must and
patulin in fruit juices, fruit nectar, spirit drinks, cider and other fermented drinks derived from apples or containing apple juice.
The aggregate sample shall be at least one litre except where it is not possible e.g. when the sample consists of one bottle.
The minimum number of incremental samples to be taken from the lot shall be as given in Table 1. The number of incremental samples determined is function of the usual form in which the products concerned are commercialised. In the case of bulk liquid products the lot shall be thoroughly mixed insofar as possible and insofar it does not affect the quality of the product, by either manual or mechanical means immediately prior to sampling. In this case, a homogeneous distribution of ochratoxin A and patulin can be assumed within a given lot. It is therefore sufficient to take three incremental samples from a lot to form the aggregate sample.
The incremental samples, which might frequently be a bottle or a package, shall be of similar weight. The weight of an incremental sample shall be at least 100 grams, resulting in an aggregate sample of at least about 1 litre. Departure from this method shall be recorded in the record provided for under part A.3.8 of Annex I.
Minimum number of incremental samples to be taken from the lot
Form of commercialisation | Volume of lot (in litres) | Minimum number of incremental samples to be taken | Minimum volume of the aggregate sample (in litres) |
---|---|---|---|
Bulk (fruit juice, spirit drinks, cider, wine) | — | 3 | 1 |
Bottles/packages (fruit juice, spirit drinks, cider) | ≤ 50 | 3 | 1 |
Bottles/packages (fruit juice, spirit drinks, cider) | 50 to 500 | 5 | 1 |
Bottles/packages (fruit juice, spirit drinks, cider) | > 500 | 10 | 1 |
Bottles/packages wine | ≤ 50 | 1 | 1 |
Bottles/packages wine | 50 to 500 | 2 | 1 |
Bottles/packages wine | > 500 | 3 | 1 |
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I(10).
Where that is not possible, an alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented.
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.
This method of sampling is of application for the official control of the maximum levels established for patulin in solid apple products and apple juice and solid apple products for infants and young children.
The aggregate sample shall be at least 1 kg, except where it is not possible e.g. when sampling a single package.
The minimum number of incremental samples to be taken from the lot shall be as given in Table 1. In the case of liquid products the lot shall be thoroughly mixed insofar as possible by either manual or mechanical means immediately prior to sampling. In this case, a homogeneous distribution of patulin can be assumed within a given lot. It is therefore sufficient to take three incremental samples from a lot to form the aggregate sample.
The incremental samples shall be of similar weight. The weight of an incremental sample shall be at least 100 grams, resulting in an aggregate sample of at least 1 kg. Departure from this method shall be recorded in the record provided for under part A.3.8 of Annex I.
Minimum number of incremental samples to be taken from the lot
Weight of lot (in kg) | Minimum number of incremental samples to be taken | Aggregate sample weight(kg) |
---|---|---|
< 50 | 3 | 1 |
50 to 500 | 5 | 1 |
> 500 | 10 | 1 |
If the lot consists of individual packages, then the number of packages, which shall be taken to form the aggregate sample, is given in Table 2.
Number of packages (incremental samples) which shall be taken to form the aggregate sample if the lot consists of individual packages
Number of packages or units in the lot | Number of packages or units to be taken | Aggregate sample weight(kg) |
---|---|---|
1 to 25 | 1 package or unit | 1 |
26 to 100 | about 5 %, at least two packages or units | 1 |
> 100 | about 5 %, at maximum 10 packages or units | 1 |
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the sampling provisions set out in this part of the Annex.
Where that is not possible, an alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented(11).
acceptance if the laboratory sample conforms to the maximum limit, taking into account the measurement uncertainty and correction for recovery,
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the measurement uncertainty and correction for recovery.
This method of sampling is of application for the official control of the maximum levels established:
for aflatoxins, ochratoxin A and Fusarium-toxins in baby foods and processed cereal-based foods for infants and young children,
for aflatoxins and ochratoxin A in dietary foods for special medical purposes (other than milk and milk products) intended specifically for infants and
for patulin in baby foods other than processed cereal based foods for infants and young children. For the control of the maximum levels established for patulin in apple juice and solid apple products for infants and young children the method of sampling as described under part I of Annex I shall apply.
The method of sampling for cereals and cereal products as set out in point B.4 of Annex I shall apply to food intended for infants and young children. Accordingly the number of incremental samples to be taken shall depend on the weight of the lot, with a minimum of 10 and a maximum of 100, in accordance with Table 2 at point B.4 of Annex I. For very small lots (≤ 0,5 tonnes) a lower number of incremental samples may be taken, but the aggregate sample uniting all incremental samples shall be also in that case at least 1 kg.
weight of the incremental sample shall be about 100 grams. In the case of lots in retail packing, the weight of the incremental sample shall depend on the weight of the retail packing and in case of very small lots (≤ 0,5 tonnes) the incremental samples shall have a weight as such that uniting the incremental samples results in an aggregate sample of at least 1 kg. Departure from this method shall be recorded in the record provided for under A.3.8.
weight of aggregate sampling = 1-10 kg sufficiently mixed.
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I.
Where that is not possible, an alternative method of sampling at retail stage may be used provided that it ensures that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented(12).
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty;
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.
This method of sampling is of application for the official control of the maximum levels established for mycotoxins, in particular aflatoxin B1, aflatoxin total and zearalenone, in vegetable oils.
The weight of the incremental sample shall be at least about 100 grams (ml) (depending of the nature of the consignment e.g. vegetable oil in bulk, at least 3 incremental samples of about 350 ml have to be taken), resulting in an aggregate sample of at least 1 kg (litre),
The minimum number of incremental samples to be taken from the lot shall be as given in Table 1. The lot shall be thoroughly mixed insofar possible by either manual or mechanical means immediately prior to sampling. In this case, a homogeneous distribution of aflatoxin can be assumed within a given lot, it is therefore sufficient to take three incremental samples from a lot to form the aggregate sample.
Table 1 | ||
Minimum number of incremental samples to be taken from the lot | ||
a On condition that the sublot can be separated physically, large bulk consignments/lots of vegetable oils shall be subdivided into sublots as foreseen in table 2 of this part. | ||
Form of commercialisation | Weight of lot (in kg) Volume of lot (in litres) | Minimum number of incremental samples to be taken |
---|---|---|
Bulk a | — | 3 |
packages | ≤ 50 | 3 |
packages | > 50 to 500 | 5 |
packages | > 500 | 10 |
Table 2 | ||||
Subdivision of lots into sublots depending on lot weight | ||||
Commodity | Lot weight (tonne) | Weight or number of sublots | Minimum N o incremental samples | Minimum aggregate sample weight (kg) |
---|---|---|---|---|
Vegetable oils | ≥ 1 500 | 500 tonnes | 3 | 1 |
> 300 and < 1 500 | 3 sublots | 3 | 1 | |
≥ 50 and ≤ 300 | 100 tonnes | 3 | 1 | |
< 50 | — | 3 | 1 |
Sampling of foodstuffs at the retail stage shall be done where possible in accordance with the provisions set out in this part of Annex I.
Where that is not possible, other effective methods of sampling at retail stage may be used provided that they ensure that the aggregate sample is sufficiently representative of the sampled lot and is fully described and documented. In any case, the aggregate sample shall be at least 1 kg (13) .
acceptance if the laboratory sample conforms to the maximum limit, taking into account the correction for recovery and measurement uncertainty,
rejection if the laboratory sample exceeds the maximum limit beyond reasonable doubt taking into account the correction for recovery and measurement uncertainty.]
Textual Amendments
OJ L 77, 16.3.2001, p. 1. Regulation as last amended by Regulation (EC) No 199/2006 (OJ L 32, 4.2.2006, p. 34).
A guidance document for competent authorities for the control of compliance with EU legislation on aflatoxins is available at http://europa.eu.int/comm/food/food/chemicalsafety/contaminants/aflatoxin_guidance_en.pdf The guidance document provides additional practical information but the information contained in the guidance document is subordinate to the provisions in this Regulation.
Guidance for sampling such lots will be provided in a guidance document available from 1 July 2006 onwards on following website: http://europa.eu.int/comm/food/food/chemicalsafety/contaminants/index_en.htm
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.
[F1In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.]
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 0,5 kg, the aggregate sample weight might be less than 0,5 kg.
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.
[F1In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.]
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 litre, the aggregate sample volume might be less than 1 litre.
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.
In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.
[F2In case the portion to be sampled is so small that it is impossible to obtain an aggregate sample of 1 kg, the aggregate sample weight might be less than 1 kg.]
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys