ANNEX VIU.K.Preparation of the mesh gauge
1.The inspector shall:U.K.
select the appropriate size of jaw for the meshes to be measured;
ensure that the jaws are clean;
check that the gauge completes the self-test satisfactorily;
select the measuring force to be applied as follows:
for active gear:
20 N for mesh sizes < 35 mm,
50 N for mesh sizes ≥ 35 mm and < 55 mm,
125 N for mesh sizes ≥ 55 mm;
for passive gear:
10 N for all mesh sizes;
verify the jaw type setting. The default setting is ‘Normal’. If small or large jaws are used, the inspector shall enter the menu and change the jaw type setting accordingly.