- Y Diweddaraf sydd Ar Gael (Diwygiedig)
- Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE)
Commission Regulation (EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3
There are outstanding changes not yet made to Commission Regulation (EU) No 1194/2012. Any changes that have already been made to the legislation appear in the content and are referenced with annotations.
Revised legislation carried on this site may not be fully up to date. Changes and effects are recorded by our editorial team in lists which can be found in the ‘Changes to Legislation’ area. Where those effects have yet to be applied to the text of the legislation by the editorial team they are also listed alongside the legislation in the affected provisions. Use the ‘more’ link to open the changes and effects relevant to the provision you are viewing.
The energy efficiency index (EEI) of the lamp is calculated as follows and rounded to two decimal places:
where:
Pcor is the rated power measured at nominal input voltage and corrected where appropriate in accordance with Table 1. The correction factors are cumulative where appropriate.
Correction factors
Pref is the reference power obtained from the useful luminous flux of the lamp (Φuse) by the following formula:
For models with Φuse < 1 300 lumen:
For models with Φuse ≥ 1 300 lumen:
Φuse is defined as follows:
directional lamps with a beam angle ≥ 90° other than filament lamps and carrying a warning on their packaging in accordance with point 3.1.2(j) of this Annex: rated luminous flux in a 120° cone (Φ120°)
other directional lamps: rated luminous flux in a 90° cone (Φ90°).
The maximum EEI of directional lamps is indicated in Table 2.
Application date | Maximum energy efficiency index (EEI) | |||
---|---|---|---|---|
Mains-voltage filament lamps | Other filament lamps | High-intensity discharge lamps | Other lamps | |
Stage 1 | If Φuse > 450 lm: 1,75 | If Φuse ≤ 450 lm: 1,20 If Φuse > 450 lm: 0,95 | 0,5 | 0,5 |
Stage 2 | 1,75 | 0,95 | 0,5 | 0,5 |
Stage 3 | 0,95 | 0,95 | 0,36 | 0,2 |
Stage 3 for mains-voltage filament lamps shall apply only if no later than 30 September 2015, evidence is produced by the Commission through a detailed market assesment and communicated to the Consultation Forum that there are mains-voltage lamps on the market that are:
compliant with the maximum EEI requirement in stage 3;
affordable in terms of not entailing excessive costs for the majority of end-users;
broadly equivalent in terms of consumer-relevant functionality parameters to mains-voltage filament lamps available on the date of entry into force of this Regulation, including in terms of luminous fluxes spanning the full range of reference luminous fluxes listed in Table 6;
compatible with equipment designed for installation between the mains and filament lamps available on the date of entry into force of this Regulation according to state-of-the-art requirements for compatibility.
As from stage 2, the no-load power of a lamp control gear intended for use between the mains and the switch for turning the lamp load on/off shall not exceed 1,0 W. As from stage 3, the limit shall be 0,50 W. For lamp control gear with output power (P) over 250 W, the no-load power limits shall be multiplied by P/250 W.
As from stage 3, the standby power of a lamp control gear shall not exceed 0,50 W.
As from stage 2, the efficiency of a halogen lamp control gear shall be at least 0,91 at 100 % load.
The lamp functionality requirements are set out in Table 3 for directional compact fluorescent lamps and in Table 4 for directional lamps excluding compact fluorescent lamps, LED lamps and high-intensity discharge lamps.
Functionality requirements for directional compact fluorescent lamps
Functionality parameter | Stage 1except where indicated otherwise | Stage 3 |
---|---|---|
Lamp survival factor at 6 000 h | From 1 March 2014: ≥ 0,50 | ≥ 0,70 |
Lumen maintenance | At 2 000 h: ≥ 80 % | At 2 000 h: ≥ 83 % At 6 000 h: ≥ 70 % |
Number of switching cycles before failure | ≥ half the lamp lifetime expressed in hours ≥ 10 000 if lamp starting time > 0,3 s | ≥ lamp lifetime expressed in hours ≥ 30 000 if lamp starting time > 0,3 s |
Starting time | < 2,0 s | < 1,5 s if P < 10 W < 1,0 s if P ≥ 10 W |
Lamp warm-up time to 60 % Φ | < 40 s or < 100 s for lamps containing mercury in amalgam form | < 40 s or < 100 s for lamps containing mercury in amalgam form |
Premature failure rate | ≤ 5,0 % at 500 h | ≤ 5,0 % at 1 000 h |
Lamp power factor for lamps with integrated control gear | ≥ 0,50 if P < 25 W ≥ 0,90 if P ≥ 25 W | ≥ 0,55 if P < 25 W ≥ 0,90 if P ≥ 25 W |
Colour rendering (Ra) | ≥ 80 ≥ 65 if the lamp is intended for outdoor or industrial applications according to point 3.1.3(l) of this Annex | ≥ 80 ≥ 65 if the lamp is intended for outdoor or industrial applications according to point 3.1.3(l) of this Annex |
If the lamp cap is a standardised type also used with filament lamps, then as from stage 2, the lamp shall comply with state-of-the-art requirements for compatibility with equipment designed for installation between the mains and filament lamps.
Functionality requirements for other directional lamps (excluding LED lamps, compact fluorescent lamps and high-intensity discharge lamps)
Functionality parameter | Stage 1 and 2 | Stage 3 |
---|---|---|
Rated lamp lifetime at 50 % lamp survival | ≥ 1 000 h (≥ 2 000 h in stage 2) ≥ 2 000 h for extra low voltage lamps not complying with the stage 3 filament lamp efficiency requirement in point 1.1 of this Annex | ≥ 2 000 h ≥ 4 000 h for extra low voltage lamps |
Lumen maintenance | ≥ 80 % at 75 % of rated average lifetime | ≥ 80 % at 75 % of rated average lifetime |
Number of switching cycles | ≥ four times the rated lamp life expressed in hours | ≥ four times the rated lamp life expressed in hours |
Starting time | < 0,2 s | < 0,2 s |
Lamp warm-up time to 60 % Φ | ≤ 1,0 s | ≤ 1,0 s |
Premature failure rate | ≤ 5,0 % at 100 h | ≤ 5,0 % at 200 h |
Lamp power factor for lamps with integrated control gear | Power > 25 W: ≥ 0,9 Power ≤ 25 W: ≥ 0,5 | Power > 25 W: ≥ 0,9 Power ≤ 25 W: ≥ 0,5 |
The lamp functionality requirements are set out in Table 5 for both non-directional and directional LED lamps.
Functionality requirements for non-directional and directional LED lamps
Functionality parameter | Requirement as from stage 1, except where indicated otherwise |
---|---|
Lamp survival factor at 6 000 h | From 1 March 2014: ≥ 0,90 |
Lumen Maintenance at 6 000 h | From 1 March 2014: ≥ 0,80 |
Number of switching cycles before failure | ≥ 15 000 if rated lamp life ≥ 30 000 h otherwise: ≥ half the rated lamp life expressed in hours |
Starting time | < 0,5 s |
Lamp warm-up time to 95 % Φ | < 2 s |
Premature failure rate | ≤ 5,0 % at 1 000 h |
Colour rendering (Ra) | ≥ 80 ≥ 65 if the lamp is intended for outdoor or industrial applications in accordance with point 3.1.3(l) of this Annex |
Colour consistency | Variation of chromaticity coordinates within a six-step MacAdam ellipse or less. |
Lamp power factor (PF) for lamps with integrated control gear | P ≤ 2 W: no requirement 2 W < P ≤ 5 W: PF > 0,4 5 W < P ≤ 25 W: PF > 0,5 P > 25 W: PF > 0,9 |
If the lamp cap is a standardised type also used with filament lamps, then as from stage 2 the lamp shall comply with state-of-the-art requirements for compatibility with equipment designed for installation between the mains and filament lamps.
0,24 for non-directional lamps (assuming that Φ use = total rated luminous flux);
0,40 for directional lamps.
When a dimming control device is switched on at its lowest control setting for which the operated lamps consume power, the operated lamps shall emit at least 1 % of their luminous flux at full load.
When a luminaire is placed on the market and lamps that the end-user can replace are included with the luminaire, these lamps shall be of one of the two highest energy classes, according to Delegated Regulation (EU) No 874/2012, with which the luminaire is labelled to be compatible.
Textual Amendments
F1 Substituted by Commission Regulation (EU) 2015/1428 of 25 August 2015 amending Commission Regulation (EC) No 244/2009 with regard to ecodesign requirements for non-directional household lamps and Commission Regulation (EC) No 245/2009 with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps and repealing Directive 2000/55/EC of the European Parliament and of the Council and Commission Regulation (EU) No 1194/2012 with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment (Text with EEA relevance).
The following information shall be provided as from stage 1, except where otherwise stipulated.
These information requirements do not apply to:
filament lamps not fulfilling the efficacy requirements of Stage 2,
LED modules when marketed as part of a luminaire from which they are not intended to be removed by the end-user.
In all forms of product information, the term ‘energy-saving lamp’ or any similar product related promotional statement about lamp efficacy may be used only if the energy efficiency index of the lamp (calculated in accordance with the method set out in point 1.1 of this Annex) is 0,40 or below.
For lamps other than high-intensity discharge lamps, the value and unit (‘lm’, ‘K’ and ‘°’) of the nominal useful luminous flux, of the colour temperature and of the nominal beam angle shall be displayed in a legible font on the surface of the lamp if, after the inclusion of safety-related information such as power and voltage, there is sufficient space available for it on the lamp without unduly obstructing the light coming from the lamp.
If there is room for only one of the three values, the nominal useful luminous flux shall be provided. If there is room for two values, the nominal useful luminous flux and the colour temperature shall be provided.
The information in paragraphs (a) to (o) below shall be displayed on free access websites and in any other form the manufacturer deems appropriate.
If the product is placed on the market in a packaging containing information to be visibly displayed to the end-users, prior to their purchase, the information shall also be clearly and prominently indicated on the packaging.
The information does not need to use the exact wording on the list below. It may be displayed in the form of graphs, drawings or symbols rather than text.
Nominal useful luminous flux displayed in a font at least twice as large as any display of the nominal lamp power;
Nominal life time of the lamp in hours (not longer than the rated life time);
Colour temperature, as a value in Kelvins and also expressed graphically or in words;
Number of switching cycles before premature failure;
Warm-up time up to 60 % of the full light output (may be indicated as ‘instant full light’ if less than 1 second);
A warning if the lamp cannot be dimmed or can be dimmed only on specific dimmers; in the latter case a list of compatible dimmers shall be also provided on the manufacturer's website;
If designed for optimum use in non-standard conditions (such as ambient temperature Ta ≠ 25 °C or specific thermal management is necessary), information on those conditions;
Lamp dimensions in millimetres (length and largest diameter);
Nominal beam angle in degrees;
If the lamp’s beam angle is ≥ 90° and its useful luminous flux as defined in point 1.1 of this Annex is to be measured in a 120° cone, a warning that the lamp is not suitable for accent lighting;
If the lamp cap is a standardised type also used with filament lamps, but the lamp’s dimensions are different from the dimensions of the filament lamp(s) that the lamp is meant to replace, a drawing comparing the lamp’s dimensions to the dimensions of the filament lamp(s) it replaces;
An indication that the lamp is of a type listed in the first column of Table 6 may be displayed only if the luminous flux of the lamp in a 90° cone (Φ90°) is not lower than the reference luminous flux indicated in Table 6 for the smallest wattage among the lamps of the type concerned. The reference luminous flux shall be multiplied by the correction factor in Table 7. For LED lamps, it shall be in addition multiplied by the correction factor in Table 8;
An equivalence claim involving the power of a replaced lamp type may be displayed only if the lamp type is listed in Table 6 and if the luminous flux of the lamp in a 90° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 6. The reference luminous flux shall be multiplied by the correction factor in Table 7. For LED lamps, it shall be in addition multiplied by the correction factor in Table 8. The intermediate values of both the luminous flux and the claimed equivalent lamp power (rounded to the nearest 1 W) shall be calculated by linear interpolation between the two adjacent values.
Reference luminous flux for equivalence claims
Extra-low voltage reflector type | ||
---|---|---|
Type | Power (W) | Reference Φ90° (lm) |
MR11 GU4 | 20 | 160 |
35 | 300 | |
MR16 GU 5.3 | 20 | 180 |
35 | 300 | |
50 | 540 | |
AR111 | 35 | 250 |
50 | 390 | |
75 | 640 | |
100 | 785 | |
Mains-voltage blown glass reflector type | ||
Type | Power (W) | Reference Φ90° (lm) |
R50/NR50 | 25 | 90 |
40 | 170 | |
R63/NR63 | 40 | 180 |
60 | 300 | |
R80/NR80 | 60 | 300 |
75 | 350 | |
100 | 580 | |
R95/NR95 | 75 | 350 |
100 | 540 | |
R125 | 100 | 580 |
150 | 1 000 | |
Mains-voltage pressed glass reflector type | ||
Type | Power (W) | Reference Φ90° (lm) |
PAR16 | 20 | 90 |
25 | 125 | |
35 | 200 | |
50 | 300 | |
PAR20 | 35 | 200 |
50 | 300 | |
75 | 500 | |
PAR25 | 50 | 350 |
75 | 550 | |
PAR30S | 50 | 350 |
75 | 550 | |
100 | 750 | |
PAR36 | 50 | 350 |
75 | 550 | |
100 | 720 | |
PAR38 | 60 | 400 |
75 | 555 | |
80 | 600 | |
100 | 760 | |
120 | 900 |
Multiplication factors for lumen maintenance
Multiplication factors for LED lamps
LED lamp beam angle | Luminous flux multiplication factor |
---|---|
20° ≤ beam angle | 1 |
15° ≤ beam angle < 20° | 0,9 |
10° ≤ beam angle < 15° | 0,85 |
beam angle < 10° | 0,8 |
If the lamp contains mercury:
Lamp mercury content as X,X mg;
Indication of which website to consult in case of accidental lamp breakage to find instructions on how to clean up the lamp debris.
As a minimum, the following information shall be expressed at least as values.
The information specified in point 3.1.2;
Rated power (0,1 W precision);
Rated useful luminous flux;
Rated lamp life time;
Lamp power factor;
Lumen maintenance factor at the end of the nominal life (except for filament lamps);
Starting time (as X,X seconds);
Colour rendering;
Colour consistency (only for LEDs);
Rated peak intensity in candela (cd);
Rated beam angle;
If intended for use in outdoor or industrial applications, an indication to this effect;
Spectral power distribution in the range 180-800 nm;
If the lamp contains mercury:
Instructions on how to clean up the lamp debris in case of accidental lamp breakage;
Recommendations on how to dispose of the lamp at the end of its life for recycling in line with Directive 2012/19/EU of the European Parliament and of the Council(1).
In addition to the product information requirements according to point 3.1 of this Annex or point 3.1 of Annex II to Regulation (EC) No 244/2009, as from stage 1, manufacturers of LED lamps replacing fluorescent lamps without integrated ballast shall publish a warning on publicly available free-access websites and in any other form they deem appropriate that the overall energy efficiency and light distribution of any installation that uses such lamps are determined by the design of the installation.
Claims that an LED lamp replaces a fluorescent lamp without integrated ballast of a particular wattage may be made only if:
the luminous intensity in any direction around the tube axis does not deviate by more than 25 % from the average luminous intensity around the tube, and
the luminous flux of the LED lamp is not lower than the luminous flux of the fluorescent lamp of the claimed wattage. The luminous flux of the fluorescent lamp shall be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent lamp in Commission Regulation (EC) No 245/2009(2), and
the wattage of the LED lamp is not higher than the wattage of the fluorescent lamp it is claimed to replace.
The technical documentation file shall provide the data to support such claims.
As from stage 2, if the equipment provides no compatibility with any of the energy-saving lamps according to part 2.3 of this Annex, a warning that the equipment is not compatible with energy-saving lamps shall be published on publicly available free-access websites and in other forms the manufacturer deems appropriate.
As from stage 2, the following information shall be published on publicly available free access websites and in other forms the manufacturer deems appropriate:
Indication that the product is intended to be used as a lamp control gear,
If applicable, the information that the product may be operated in no-load mode.
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys