xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"
Measurement-based methodologies shall be approved in accordance with tiers with the following maximum permissible uncertainties for the annual average hourly emissions calculated in accordance with Equation 2 set out in section 3 of this Annex.
Tiers for CEMS (maximum permissible uncertainty for each tier)
Tier 1 | Tier 2 | Tier 3 | Tier 4 | |
---|---|---|---|---|
CO2 emission sources | ± 10 % | ± 7,5 % | ± 5 % | ± 2,5 % |
N2O emission sources | ± 10 % | ± 7,5 % | ± 5 % | N.A. |
CO2 transfer | ± 10 % | ± 7,5 % | ± 5 % | ± 2,5 % |
Minimum requirements for measurement-based methodologies
Greenhouse gas | Minimum tier level required | ||
---|---|---|---|
Category A | Category B | Category C | |
CO2 | 2 | 2 | 3 |
N2O | 2 | 2 | 3 |
Where:
=
hourly concentrations of emissions in g/Nm3 in the flue gas flow measured during operation;
=
flue gas flow in Nm3 for each hour.
Where:
=
annual average hourly emissions in kg/h from the source;
=
hourly concentrations of emissions in g/Nm3 in the flue gas flow measured during operation;
=
flue gas flow in Nm3 for each hour.
Where:
=
the arithmetic mean of the concentration of the specific parameter over the whole reporting period or, where specific circumstances applied when data loss occurred, an appropriate period reflecting the specific circumstances;
=
the best estimate of the standard deviation of the concentration of the specific parameter over the whole reporting or, where specific circumstances applied when data loss occurred, an appropriate period reflecting the specific circumstances.