D1 A building shall be designed and constructed so that the combined dead, imposed and wind loads are sustained and transmitted to the ground, taking into account the nature of the ground—
(a)safely; and
(b)without impairing the safety of any part of another building.
D2—(1) A building to which this paragraph applies shall be designed and constructed so that in the event of damage occurring to any part of the building, the extent of any resulting collapse will not be disproportionate to the cause of the damage.
(2) Paragraph (1) applies to a building having 5 or more storeys, counting each basement level as one storey but discounting a storey within a roof space where the slope of the roof does not exceed 70° to the horizontal.
D3—(1) The requirements of regulation D1 shall be deemed to be satisfied—
(a)if any loadings to which the building will be subjected, specified in column (2) of the Table in Schedule 4, are calculated in accordance with the relevant provisions of the publications specified opposite there to in column (3), as amended by the publications specified opposite thereto in column (4):
Provided that—
the actual loads are used, where the actual loads to which the building is to be subjected are likely to exceed the loads so calculated; and
loads used allow for possible dynamic, concentrated and peak load effects which may occur; and
(b)in the case of any structural work specified in column (2) of Table D opposite the reference to that regulation, if the structural work is designed and constructed in accordance with the relevant provisions of the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).
(2) The requirements of regulation D2 shall be deemed to be satisfied, in the case of any structural work specified in column (2) of Table D opposite the reference to that regulation, if the structural work is designed and constructed in accordance with the relevant provisions of the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys