10. A machine made in accordance with an approved pattern and which is or could be marked
is a Class I machine.
11. The specifications for non-graduated and graduated Class I machines are given in Table 1.
Maximum capacity “Max” | Lower limit of the minimum load “Min” | Scale interval “d” | Number of scale intervals “n” | Verification scale interval “e” |
---|---|---|---|---|
Non-graduated machines | ||||
100 mg ≤ Max | 10 e | 0.1 mg | ||
≤ 1 g | ||||
1 g ≤ Max | 50 e | Max | ||
<10 g | ... ... ... ... | |||
10 000 | ||||
10 g ≤ Max | 50 e | 1 mg | ||
<100 g | ||||
100 g ≤ Max | 50 e | Max | ||
... ... ... ... | ||||
100 000 | ||||
Graduated machines | ||||
0.5 mg ≤ Max | d | d ≤ 0.005 mg | 10 ≤ n | d |
1 mg ≤ Max | 10 d | 0.01 mg ≤ d | 100 ≤ n | d |
≤ 0.05 mg | ||||
10 mg ≤ Max | 50 d | 0.1 mg ≤ d | 100 ≤ n | d |
≤ 0.5 mg | ||||
100 g ≤ Max | 50 d | 1 mg ≤ d | 100 000 ≤ n | d |
1. When a machine is provided with a rider its verification scale interval shall be the smaller of the following—
(i)the verification scale interval of the machine not taking into account the rider, or
(ii)the scale interval of the rider device.
2. When graduated machines of the self and semi-self indicating type are provided with a device for interpolation of reading, this shall not be taken into account when determining the verification scale interval of the machine.
3. When graduated machines of the self or semi-self indicating type are provided with an indicating device on which the last figure is clearly differentiated from the other figures, the verification scale interval shall correspond to the last but one figure of the indication.
4. In the case of machines where the weight indicating or printing is in carat (metric) units or ounces troy the relevant capacity and verification scale interval shall be the amounts in carat (metric) or ounces troy respectively which are equivalent to those specified in the Table in terms of mg, g and kg.
5. Where the equivalent metric value for an ounce troy scale interval falls between ranges then the value shall be considered as belonging to the lower range.
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys