Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
12. A machine which is:N.I.
(a)made in accordance with an approved pattern and which is or could be marked
, or
(b)first stamped before 1st November 1991 and marked “Class B” in accordance with the provisions for beam scales in the Weights and Measures Regulations (Northern Ireland) 1967,
is a Class II machine.
Commencement Information
I1Sch. 1 para. 12 in operation at 13.2.2006, see reg. 1(1)
13. The specifications for non-graduated and graduated Class II machines are given in Table 2.N.I.
Maximum capacity“Max” | Lower limit of the minimum load“Min” | Scale interval“d” | Number of scale intervals“n” | Verification scale interval“e” |
---|---|---|---|---|
Non-graduated machines | ||||
1 g ≤ Max <5 g | 10 e | Max | ||
... ... ... ... | ||||
1 000 | ||||
5 g ≤ Max | 10 e | 5 mg | ||
<100 g | ||||
100 g ≤ Max | 10 e | Max | ||
<200 g | ... ... ... ... | |||
20 000 | ||||
200 g ≤ Max | 50 e | Max | ||
... ... ... ... | ||||
20 000 | ||||
Graduated machines | ||||
Non-self indicating machines | ||||
1 g ≤ Max <50 g | 10 d | 1 mg ≤ d ≤ 5 mg | 200 ≤ n <50 000 | d |
10 g ≤ Max <50 g | 50 d | 10 mg ≤ d ≤ 50 mg | 1 000 ≤ n < 5 000 | 5 mg |
50 g ≤ Max ≤500 g | 10 d | 1 mg ≤ d ≤ 5 mg | 10 000 ≤ n ≤ 100 000 | d |
50 g ≤ Max <5 kg | 50 d | 10 mg ≤ d ≤ 500 mg | 1 000 ≤ n < 10 000 | Max |
10 000 | ||||
100 g ≤ Max ≤ 50 kg | 50 d | 10 mg ≤ d ≤ 500 mg | 10 000 ≤ n ≤ 100 000 | d |
5 kg ≤ Max | 50 d | 1 g ≤ d | 5 000 ≤ n <10 000 | Max |
10 000 | ||||
10 kg ≤ Max | 50 d | 1 g ≤ d | 10 000 ≤ n ≤ 100 000 | d |
Self and semi-self indicating machines | ||||
1 g ≤ Max ≤ 500 g | 10 d | 1 mg ≤ d ≤ 5 mg | 200 ≤ n ≤ 100 000 | d |
10 g ≤ Max ≤ 50 kg | 50 d | 10 mg ≤ d ≤ 500 mg | 1 000 ≤ n ≤ 100 000 | d |
5 kg ≤ Max | 50 d | 1 g ≤ d | 5 000 ≤ n ≤ 100 000 | d |
Commencement Information
I2Sch. 1 para. 13 in operation at 13.2.2006, see reg. 1(1)
1. When a machine is provided with a rider its verification scale interval shall be the smaller of the following—
(i)the verification scale interval of the machine not taking into account the rider, or
(ii)the scale interval of the rider device.
Commencement Information
I3Sch. 1 Pt. III para. 1 in operation at 13.2.2006, see reg. 1(1)
2. When graduated self or semi-self indicating machines are provided with a device for interpolation of reading, this shall not be taken into account when determining the verification scale interval of the machine.
Commencement Information
I4Sch. 1 Pt. III para. 2 in operation at 13.2.2006, see reg. 1(1)
3. When graduated self or semi-self indicating machines are provided with an indicating device on which the last figure is clearly differentiated from the other figures, the verification scale interval shall correspond to the last but one figure of the indication.
Commencement Information
I5Sch. 1 Pt. III para. 3 in operation at 13.2.2006, see reg. 1(1)
4. Machines of a maximum capacity equal to or greater than 1 kg of an actual scale interval of 100 mg and of a verification scale interval of 1 g may belong to this class of machine, provided that the last figure is clearly differentiated from the other figures.
Commencement Information
I6Sch. 1 Pt. III para. 4 in operation at 13.2.2006, see reg. 1(1)
5. In the case of machines where the weight indicating or printing is in carat (metric) units or ounces troy the relevant capacity and verification scale interval shall be the amounts in carat (metric) or ounces troy respectively which are equivalent to those specified in the Table in terms of mg, g and kg.
Commencement Information
I7Sch. 1 Pt. III para. 5 in operation at 13.2.2006, see reg. 1(1)
6. Where the equivalent metric value for an ounce troy scale interval falls between ranges then the value shall be considered as belonging to the lower range.
Commencement Information
I8Sch. 1 Pt. III para. 6 in operation at 13.2.2006, see reg. 1(1)
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys