This is a draft item of legislation. This draft has since been made as a UK Statutory Instrument: The Ecodesign for Energy-Related Products and Energy Information (Lighting Products) Regulations 2021 No. 1095
2.—(1) An equivalence claim involving the power of a replaced light source type may be given only—
(a)for directional light sources, if the light source type is listed in Table 7 and the luminous flux of the light source in a 90° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 7, and for this purpose—
(i)the reference luminous flux must be multiplied by the correction factor in Table 8; and
(ii)for LED light sources, it must in addition be multiplied by the correction factor in Table 9;
(b)for non-directional light sources, if the claimed equivalent incandescent light source power (in Watts, rounded to the nearest integer) corresponds to the luminous flux of the light source in Table 10.
(2) The intermediate values of both the luminous flux and the claimed equivalent light source power (in Watts, rounded to the integer) must be calculated by linear interpolation between the two adjacent values.
(3) A claim that a LED light source replaces a fluorescent light source without integrated ballast of a particular wattage may be made only if—
(a)the luminous intensity in any direction around the tube axis does not deviate by more than 25% from the average luminous intensity around the tube;
(b)the luminous flux of the LED light source is not lower than the luminous flux of the fluorescent light source of the claimed wattage; and
(c)the wattage of the LED light source is not higher than the wattage of the fluorescent light source it is claimed to replace.
(4) For light sources that can be tuned to emit light at full-load with different characteristics, the values of parameters that vary with these characteristics must be reported at the reference control settings.
(5) For the purposes of sub-paragraph (3)(b), the luminous flux of the fluorescent light source must be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent light source in Table 11.
Type | Power | Reference Φ90° (lm) |
Extra-low voltage reflector type | ||
MR11 GU4 | 20 | 160 |
35 | 300 | |
MR16 GU 5.3 | 20 | 180 |
35 | 300 | |
50 | 540 | |
AR111 | 35 | 250 |
50 | 390 | |
75 | 640 | |
100 | 785 | |
Mains-voltage blown glass reflector type | ||
R50/NR50 | 25 | 90 |
40 | 170 | |
R63/NR63 | 40 | 180 |
60 | 300 | |
R80/NR80 | 60 | 300 |
75 | 350 | |
100 | 580 | |
R95/NR95 | 75 | 350 |
100 | 540 | |
R125 | 100 | 580 |
150 | 1,000 | |
Mains-voltage pressed glass reflector type | ||
PAR16 | 20 | 90 |
25 | 125 | |
35 | 200 | |
50 | 300 | |
PAR20 | 35 | 200 |
50 | 300 | |
75 | 500 | |
PAR25 | 50 | 350 |
75 | 550 | |
PAR30S | 50 | 350 |
75 | 550 | |
100 | 750 | |
PAR36 | 50 | 350 |
75 | 550 | |
100 | 720 | |
PAR38 | 60 | 400 |
75 | 555 | |
80 | 600 | |
100 | 760 | |
120 | 900 |
Light source type | Luminous flux multiplication factor |
---|---|
Halogen light sources | 1 |
Fluorescent light sources | 1.08 |
LED light sources | 1 + 0.5 × (1 - LLMF) where LLMF is the lumen maintenance factor at the end of the declared lifetime |
LED light source beam angle | Luminous flux multiplication factor |
---|---|
20° ≤ beam angle | 1 |
15° ≤ beam angle < 20° | 0.9 |
10° ≤ beam angle < 15° | 0.85 |
beam angle < 10° | 0.8 |
Light source luminous flux Φ (lm) | Claimed equivalent incandescent light source power (W) |
---|---|
136 | 15 |
249 | 25 |
470 | 40 |
806 | 60 |
1,055 | 75 |
1,521 | 100 |
2,452 | 150 |
3,452 | 200 |
T8 (26 mm Ø) | T5 (16 mm Ø) High Efficiency | T5 (16 mm Ø) High output | |||
---|---|---|---|---|---|
Claimed equivalent power (W) | Minimum luminous efficacy (lm/W) | Claimed equivalent power (W) | Minimum luminous efficacy (lm/W) | Claimed equivalent power (W) | Minimum luminous efficacy (lm/W) |
15 | 63 | 14 | 86 | 24 | 73 |
18 | 75 | 21 | 90 | 39 | 79 |
25 | 76 | 28 | 93 | 49 | 88 |
30 | 80 | 35 | 94 | 54 | 82 |
36 | 93 | 80 | 77 | ||
38 | 87 | ||||
58 | 90 | ||||
70 | 89 |
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Mae Memorandwm Esboniadol Drafft yn nodi datganiad byr o ddiben Offeryn Statudol Drafft ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Eu nod yw gwneud yr Offeryn Statudol Drafft yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd yn fanwl gerbron y Senedd o Fehefin 2004 ymlaen.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys