Type of equipment | Net installed power P (in kW) Electric power Pel a in kW Mass of appliance m in kg Cutting width L in cm | Permissible sound power level in dB/1 pW | |
---|---|---|---|
Stage I as from 3 January 2002 | Stage II as from 3 January 2006 | ||
a Pel for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. Pel for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2. | |||
b For the following types of equipment the figures for Stage I shall continue to apply for Stage II—
| |||
c For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply. | |||
Compaction machines (vibrating rollers, vibratory plates, vibratory rammers) | P ≤ £ 8 | 108 | 105b |
8 < P ≤ £70 | 109 | 106b | |
P > 70 | 89 + 11 1g P | 86 + 11 1g Pb | |
Tracked dozers, tracked loaders, tracked excavator-loaders | P ≤ 55 | 106 | 103b |
P > 55 | 87 + 11 1g P | 84 + 11 1g Pb | |
Wheeled dozers,wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, compaction machines (non-vibrating rollers),paver-finishers, hydraulic power packs | P ≤ 55 | 104 | 101b |
P > 55 | 85 + 11 1g P | 82 + 11 1g Pb | |
Mobile cranes | P ≤ 55 | 104 | 101c |
P > 55 | 85 + 11 1g P | 82 + 11 1g P 101c | |
Excavators, builders' hoists for the transport of goods, construction winches, motor hoes | P ≤ 15 | 96 | 93 |
P > 15 | 83 + 11 1g P | 80 + 11 1g P | |
Hand-held concrete-breakers and picks | m ≤ 15 | 107 | 105 |
15< m < 30 | 94 + 11 1g m | 92 + 11 1g mb | |
m ≥ 30 | 96 + 11 1g m | 94 + 11 1g m | |
Tower cranes | 98 + 1g P | 96 + 1g P | |
Welding and power generators | Pel ≤ 2 | 97 + 1g Pel | 95 + 1g Pel |
2 < Pel ≤ 10 | 98 + 1g Pel | 96 + 1g Pel | |
10 > Pel | 97 + 1g Pel | 95 + 1g Pel | |
Compressors | P ≤ 15 | 99 | 97 |
P > 15 | 97 + 2 1g Pel | 95 + 2 1g Pel | |
Lawnmowers, lawn trimmers/lawn-edge trimmers | L ≤ 50 | 96 | 96 |
50 < L ≤ 70 | 100 | 98 | |
70 < L ≤ 120 | 100 | 100 | |
L > 120 | 105 | 105 | |
The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0.5, use lower number; greater than or equal to 0.5, use higher number). |