Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

PART 5U.K.QUALITY AND SAFETY REQUIREMENTS FOR BLOOD AND BLOOD COMPONENTS

1.  THE BLOOD COMPONENTSU.K.

1. Red cell preparationsThe components listed in points 1.1 to 1.8 may be further processed within blood establishments and must be labelled accordingly
1.1Red cells
1.2Red cells, buffy coat removed
1.3Red cells, leucocyte-depleted
1.4Red cells, in additive solution
1.5Red cells, buffy coat removed, in additive solution
1.6Red cells, leucocyte-depleted, in additive solution
1.7Red cells, apheresis
1.8Whole blood
2. Platelet preparationsThe components listed in points 2.1 to 2.6 may be further processed within blood establishments and must be labelled accordingly
2.1Platelets, apheresis
2.2Platelets, apheresis, leucocyte-depleted
2.3Platelets, recovered, pooled
2.4Platelets, recovered, pooled, leucocyte-depleted
2.5Platelets, recovered, single unit
2.6Platelets, recovered, single unit, leucocyte-depleted
3. Plasma preparationsThe components listed in 3.1 to 3.3 may be further processed within blood establishments and must be labelled accordingly
3.1Fresh-frozen plasma
3.2Fresh-frozen plasma, cryoprecipitate-depleted
3.3Cryoprecipitate
4.Granulocytes, apheresis

2.  QUALITY CONTROL REQUIREMENTS FOR BLOOD AND BLOOD COMPONENTSU.K.

2.1.  Blood and blood components must comply with the following technical quality measurements and meet the acceptable results.U.K.

2.2.  Appropriate bacteriological control of the collection and manufacturing process must be performed.U.K.

2.3.  For autologous donations, the measures marked with an asterisk (*) are recommendations only.U.K.

ComponentQuality measures requiredAcceptable results for quality measures
 The required frequency of sampling for all measurements shall be determined using statistical process control 
Red cellsVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 45g per unit
 HaemolysisLess than 0.8% of red cell mass at end of the shelf life
Red cells, buffy coat removedVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 43 g per unit
 HaemolysisLess than 0.8% of red cell mass at the end of the shelf life
Red cells, leucocyte-depletedVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 40g per unit
 Leucocyte contentLess than 1 x 106 per unit
 HaemolysisLess than 0.8% of red cell mass at the end of the shelf life
Red cells, in additive solutionVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 45g per unit
 HaemolysisLess than 0.8% of red cell mass at end of the shelf life
Red cells, buffy coat removed, in additive solutionVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 43g per unit
 HaemolysisLess than 0.8% of red cell mass at the end of the shelf life
Red cells, leucocyte-depleted, in additive solutionVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 40g per unit
 Leucocyte contentLess than 1 x 106 per unit
 HaemolysisLess than 0.8% of red cell mass at the end of the shelf life
Red cells, apheresisVolumeValid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
 Haemoglobin (*)Not less than 40g per unit
 HaemolysisLess than 0.8% of red cell mass at the end of the shelf life
Whole bloodVolume

Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis 450ml +/- 50ml

For paediatric autologous whole blood collections – not to exceed 10.5ml per kg body weight

 Haemoglobin (*)Not less than 45g per unit
 HaemolysisLess than 0.8% of red cell mass at the end of the shelf life
Platelets, apheresisVolumeValid for storage characteristics to maintain product within specifications for pH
 Platelet contentVariations in platelet content per single donation are permitted within the limits that comply with validated preparation and preservation conditions
 pH [F1Minimum 6.4 corrected for 22°C, at the end of the shelf life]
Platelets, apheresis, leucocyte-depletedVolumeValid for storage characteristics to maintain product within specifications for pH
 Platelet contentVariations in platelet content per single donation are permitted within the limits that comply with validated preparation and preservation conditions
 Leucocyte contentLess than 1 x 106 per unit
 pH [F1Minimum 6.4 corrected for 22°C, at the end of the shelf life]
Platelets, recovered, pooledVolumeValid for storage characteristics to maintain product within specifications for pH
 Platelet contentVariations in platelet content per pool are permitted within limits that comply with validated preparation and preservation conditions
 Leucocyte content

Less than 0.2 x 109 per single unit (platelet-rich plasma method)

Less than 0.05 x 109 per single unit (buffy coat method)

 pH [F1Minimum 6.4 corrected for 22°C, at the end of the shelf life]
Platelets, recovered, pooled, leucocyte-depletedVolumeValid for storage characteristics to maintain product within specifications for pH
 Platelet contentVariations in platelet content per pool are permitted within limits that comply with validated preparation and preservation conditions
 Leucocyte contentLess than 1 x 106 per pool
 pH [F1Minimum 6.4 corrected for 22°C, at the end of the shelf life]
Platelets, recovered, single unitVolumeValid for storage characteristics to maintain product within specifications for pH
 Platelet contentVariations in platelet content per single unit are permitted within limits that comply with validated preparation and preservation conditions
 Leucocyte content

Less than 0.2 x 109 per single unit (platelet-rich plasma method)

Less than 0.05 x 109 per single unit (buffy coat method)

 pH [F1Minimum 6.4 corrected for 22°C, at the end of the shelf life]
Platelets, recovered, single unit, leucocyte-depletedVolumeValid for storage characteristics to maintain product within specifications for pH
 Platelet contentVariations in platelet content per single unit are permitted within limits that comply with validated preparation and preservation conditions
 Leucocyte contentLess than 1 x 106 per unit
 pH [F1Minimum 6.4 corrected for 22°C, at the end of the shelf life]
Plasma, fresh-frozenVolumeStated volume +/- 10%
 Factor VIIIc(*)Average (after freezing and thawing): 70% or more of the value of the freshly collected plasma unit
 Total proteinNot less than 50g/l
 Residual cellular content(*)

Red cells: less than 6.0 x 109/l

Leucocytes: less than 0.1 x 109/l

Platelets: less than 50 x 109/l

Plasma, fresh-frozen, cryoprecipitate-depletedVolumeStated volume +/-10%
 Residual cellular content(*)

Red cells: less than 6.0 x 109/l

Leucocytes: less than 0.1 x 109/l

Platelets: less than 50 x 109/l

CryoprecipitateFribrinogen content(*)Greater than or equal to 140mg per unit
 Fractor VIIIc content (*)Greater than or equal to 70 international units per unit
Granulocytes, apheresisVolumeLess than 500ml
 Granulocyte contentGreater than 1 x 1010 granulocytes per unit

Textual Amendments

F1Words in Sch. Pt. 5 para. 2 Table substituted (18.7.2016) by The Blood Safety and Quality (Amendment) Regulations 2016 (S.I. 2016/604), regs. 1, 2(3)

Yn ôl i’r brig

Options/Help

Print Options

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.

Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

Gweler y wybodaeth ychwanegol ochr yn ochr â’r cynnwys

Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Memorandwm Esboniadol

Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel deddfwyd fersiwn a ddefnyddiwyd am y copi print
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Llinell Amser Newidiadau

This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.

Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel gwnaed fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill