Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
Regulation 11
1.—(1) The local authority must ensure that each sample is—
(a)taken by a competent person using suitable equipment;
(b)representative of the water at the sampling point at the time of sampling;
(c)not contaminated in the course of being taken;
(d)kept at such temperature and in such conditions as will secure that there is no material change in what is to be measured; and
(e)analysed without delay by a competent person using suitable equipment.
(2) It must ensure that the sample is analysed using a system of analytical quality control.
(3) The system must be subjected to checking by a person who is—
(a)not under the control of either the analyst or the local authority; and
(b)approved by the Secretary of State for that purpose.
2.—(1) The local authority must ensure that each sample is analysed in accordance with this paragraph.
(2) For each parameter specified in the first column of Table 1 in Part 2 of this Schedule the method of analysis is specified in the second column of that table.
(3) For each parameter specified in the first column of Table 2 in Part 2 of this Schedule the method is one that is capable of—
(a)measuring concentrations and values with the trueness and precision specified in the second and third columns of that table, and
(b)detecting the parameter at the limit of detection specified in the fourth column of that table.
(4) For hydrogen ion, the method of analysis must be capable of measuring a value with a trueness of 0.2 pH unit and a precision of 0.2 pH unit.
(5) The method of analysis used for odour and taste parameters must be capable of measuring values equal to the parametric value with a precision of 1 dilution number at 25°C.
(6) For these purposes—
“limit of detection” is —
three times the relative within-batch standard deviation of a natural sample containing a low concentration of the parameter; or
five times the relative within-batch standard deviation of a blank sample;
“precision” (the random error) is twice the standard deviation (within a batch and between batches) of the spread of results about the mean;
“trueness” (the systematic error) is the difference between the mean value of the large number of repeated measurements and the true value.
3.—(1) The Secretary of State may authorise a method different from that set out in paragraph 2(2) if satisfied that it is at least as reliable.
(2) An authorisation may be time-limited and may be revoked at any time.
4.—(1) A local authority may enter into an arrangement for any person to take and analyse samples on its behalf.
(2) A local authority must not enter into an arrangement under paragraph (1) unless—
(a)it is satisfied that the task will be carried out promptly by a person competent to perform it, and
(b)it has made arrangements that ensure that any breach of these Regulations is communicated to it immediately, and any other result is communicated to it within 28 days.
Prescribed methods of analysis
*Use the following method to make m-CP agar: | |
Parameter | Method |
---|---|
Clostridium perfringens (including spores) | Membrane filtration followed by anaerobic incubation of the membrane on m-CP agar* at 44 ± 1°C for 21 ± 3 hours. Count opaque yellow colonies that turn pink or red after exposure to ammonium hydroxide vapours for 20 to 30 seconds. |
Coliform bacteria | BS-EN ISO 9308-1 |
Colony count 22°C-enumeration of culturable microorganisms | BS-EN ISO 6222 |
Colony count 37°C-enumeration of culturable microorganisms | BS-EN ISO 6222 |
Enterococci | BS-EN ISO 7899-2 |
Escherichia coli (E. coli) | BS-EN ISO 9308-1 |
Pseudomonas aeruginosa | BS-EN ISO 12780 |
Make a basal medium consisting of—
Tryptose | 30.0g |
Yeast extract | 20.0g |
Sucrose | 5.0g |
L-cysteine hydrochloride | 1.0g |
MgSO4.7H2O | 0.1g |
Bromocresol purple | 40.0mg |
Agar | 15.0g |
Water | 1,000.0ml |
Dissolve the ingredients of the basal medium, adjust pH to 7.6 and autoclave at 121°C for 15 minutes. Allow the medium to cool.
Dissolve—
D-cycloserine | 400.0mg |
Polymyxine-B sulphate | 25.0mg |
Indoxyl-β-D-glucoside | 60.0mg |
into 8ml sterile water and add it to the medium.
Add to the medium—
Filter-sterilised 0.5% phenolphthalein diphosphate solution | 20.0ml |
Filter-sterilised 4.5% FeCl3.6H2O | 2.0ml |
Prescribed performance characteristics for methods of analysis
Notes: | |||
1 The method of analysis should determine total cyanide in all forms. | |||
2 The performance characteristics apply to each individual pesticide and will depend on the pesticide concerned. | |||
3 The performance characteristics apply to the individual substances specified at 25% of the parametric value in Part 1 of Table B in Schedule 1. | |||
4 The performance characteristics apply to the individual substances specified at 50% of the parametric value in Part 1 of Table B in Schedule 1. | |||
5 The performance characteristics apply to the prescribed value of 4 NTU. | |||
6 The performance characteristics apply to the specification of 1 NTU for surface waters or ground waters influenced by surface water. | |||
Parameters | Trueness % of prescribed concentration or value or specification | Precision % of prescribed concentration or value or specification | Limit of detection % of prescribed concentration or value or specification |
---|---|---|---|
Aluminium | 10 | 10 | 10 |
Ammonium | 10 | 10 | 10 |
Antimony | 25 | 25 | 25 |
Arsenic | 10 | 10 | 10 |
Benzene | 25 | 25 | 25 |
Benzo(a)pyrene | 25 | 25 | 25 |
Boron | 10 | 10 | 10 |
Bromate | 25 | 25 | 25 |
Cadmium | 10 | 10 | 10 |
Chloride | 10 | 10 | 10 |
Chromium | 10 | 10 | 10 |
Colour | 10 | 10 | 10 |
Conductivity | 10 | 10 | 10 |
Copper | 10 | 10 | 10 |
Cyanide 1 | 10 | 10 | 10 |
1,2-dichloroethane | 25 | 25 | 10 |
Fluoride | 10 | 10 | 10 |
Iron | 10 | 10 | 10 |
Lead | 10 | 10 | 10 |
Manganese | 10 | 10 | 10 |
Mercury | 20 | 10 | 20 |
Nickel | 10 | 10 | 10 |
Nitrate | 10 | 10 | 10 |
Nitrite | 10 | 10 | 10 |
Pesticides and related products 2 | 25 | 25 | 25 |
Polycyclic aromatic hydrocarbons 3 | 25 | 25 | 25 |
Selenium | 10 | 10 | 10 |
Sodium | 10 | 10 | 10 |
Sulphate | 10 | 10 | 10 |
Tetrachloroethene 4 | 25 | 25 | 10 |
Tetrachloromethane | 20 | 20 | 20 |
Trichloroethene 4 | 25 | 25 | 10 |
Trihalomethanes: Total 3 | 25 | 25 | 10 |
Turbidity 5 | 10 | 10 | 10 |
Turbidity 6 | 25 | 25 | 25 |
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys