4.  As a minimum, the following information and properties—where appropriate—must be considered or tested. Each civil explosive should be tested under realistic conditions. If this is not possible in a laboratory, the tests should be carried out in the conditions in which the civil explosive is to be used.

(a)Design and characteristic properties, including chemical composition, degree of homogeneity and, where appropriate, dimensions and grain size distribution.

(b)The physical and chemical stability of the civil explosive in all environmental conditions to which it may be exposed.

(c)Sensitiveness to impact and friction.

(d)Compatibility of all components as regards their physical and chemical stability.

(e)The chemical purity of the civil explosive.

(f)Resistance of the civil explosive against influence of water where it is intended to be used in humid or wet conditions and where its safety or reliability may be adversely affected by water.

(g)Resistance to low and high temperatures, where the civil explosive is intended to be kept or used at such temperatures and its safety or reliability may be adversely affected by cooling or heating of a component or of the civil explosive as a whole.

(h)The suitability of the civil explosive for use in hazardous environments (e.g. firedamp atmospheres, hot masses, etc.) if it is intended to be used under such conditions.

(i)Safety features intended to prevent untimely or inadvertent initiation or ignition.

(j)The correct loading and functioning of the civil explosive when used for its intended purpose.

(k)Suitable instructions and, where necessary, markings in respect of safe handling, storage, use and disposal in the official language or languages of the recipient EEA state.

(l)The ability of the civil explosive, its wrapping or other components to withstand deterioration during storage until the “use by” date specified by the manufacturer.

(m)Specification of all devices and accessories needed for reliable and safe functioning of the civil explosive.

5.  The various groups of civil explosives must at least also comply with the following requirements:

(a)Blasting Explosives

(i)The proposed method of initiation must ensure safe, reliable and complete detonation or deflagration as appropriate, of the blasting explosive. In the particular case of black powder, it is the capacity as regards deflagration which is to be checked.

(ii)Blasting explosives in cartridge form must transmit the detonation safely and reliably from one end of the train of cartridges to the other.

(iii)The fumes produced by blasting explosives intended for underground use may contain carbon monoxide, nitrous gases, other gases, vapours or airborne solid residues only in quantities which do not impair health under normal operating conditions.

(b)Detonating cords, safety fuses, other fuses and shock tubes

(i)The covering of detonating cords, safety fuses and other fuses must be of adequate mechanical strength and adequately protect the explosive filling when exposed to normal mechanical stress.

(ii)The parameters for the burning times of safety fuses must be indicated and must be reliably set.

(iii)Detonating cords must be capable of being reliably initiated, be of sufficient initiation capability and comply with requirements as regards storage even in particular climatic conditions.

(c)Detonators (including delay detonators) and relays

(i)Detonators must reliably initiate the detonation of the blasting explosives which are intended to be used with them under all foreseeable conditions of use.

(ii)Delay connectors for detonating cords must be reliably initiated.

(iii)The initiation capability must not be adversely affected by humidity.

(iv)The delay times of delay detonators must be sufficiently uniform to ensure that the probability of overlapping of the delay times of adjacent time steps is insignificant.

(v)The electrical characteristics of electric detonators must be indicated on the packaging (e.g. no-fire current, resistance, etc.).

(vi)The wires of electric detonators must be of sufficient insulation and mechanical strength including the solidity of the link to the detonator, taking account of their intended use.

(d)Propellants and rocket propellants

(i)These materials must not detonate when used for their intended purpose.

(ii)Propellants where necessary (e.g. those based on nitrocellulose) must be stabilised against decomposition.

(iii)Solid rocket propellants, when in compressed or cast form, must not contain any unintentional fissures or gas bubbles which dangerously affect their functioning.

Yn ôl i’r brig

Options/Help

Print Options

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Memorandwm Esboniadol

Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel deddfwyd fersiwn a ddefnyddiwyd am y copi print
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Asesiadau Effaith

Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:

  • Why the government is proposing to intervene;
  • The main options the government is considering, and which one is preferred;
  • How and to what extent new policies may impact on them; and,
  • The estimated costs and benefits of proposed measures.
Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel gwnaed fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill