Point in time view as at 21/11/2016.
There are currently no known outstanding effects for the The Merchant Shipping and Fishing Vessels (Health and Safety at Work) (Electromagnetic Fields) Regulations 2016, PART 2.
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
Commencement Information
I1Sch. Pt. 2 in force at 21.11.2016, see reg. 1
Frequency range | External electric field strength Low ALs (E) [Vm-1] | External electric field strength High ALs (E) [Vm-1] |
---|---|---|
1 ≤ f < 25 Hz | 2.0 × 104 | 2.0 × 104 |
25 ≤ f < 50 Hz | 5.0 × 105/f | 2.0 × 104 |
50 Hz ≤ f < 1.64 kHz | 5.0 × 105/f | 1.0 × 106/f |
1.64 ≤ f < 3 kHz | 5.0 × 105/f | 6.1 × 102 |
3 kHz ≤ f ≤ 10 MHz | 1.7 × 102 | 6.1 × 102 |
Exposure levels not exceeding the ALs will be compliant with: | Tables ELV2 and ELV3 |
NOTES
1. Between the Low and High ALs, exposure will be below the ELVs but spark discharges may occur. These can be prevented through the provision of information and training under regulation 19 and the use of suitable technical and personal protection measures.U.K.
2. The ALs in Tables AL1 and AL2 are root mean square (RMS) values of the field strength. These RMS values are equal to the peak values divided by √2 for sinusoidal fields. The corresponding ELVs in Tables ELV2 and ELV3 are peak values in time, which are equal to the RMS values multiplied by √2 for sinusoidal fields. In the case of non-sinusoidal fields, the exposure assessment under regulation 6 must be based on the weighted peak method (filtering in time domain) or on a scientifically proven and validated exposure evaluation procedure which produces comparable results to the weighted peak method.U.K.
3. The ALs represent the maximum field values at any place where a worker may be working, before the entry of any person into the field. In the case of an electromagnetic field source in the immediate vicinity of the body, compliance with the ELVs must be determined dosimetrically on a case by case basis.U.K.
Frequency Range | Magnetic flux density Low ALs (B) [µT] | Magnetic flux density High ALs (B) [µT] | Magnetic flux density ALs for exposure of limbs to a localised magnetic field (B) [µT] |
---|---|---|---|
1 ≤ f < 8 Hz | 2.0 × 105/f2 | 3.0 × 105/f | 9.0 × 105/f |
8 ≤ f < 25 Hz | 2.5 × 104/f | 3.0 × 105/f | 9.0 × 105/f |
25 ≤ f < 300 Hz | 1.0 × 103 | 3.0 × 105/f | 9.0 × 105/f |
300 Hz ≤ f < 3 kHz | 3.0 × 105/f | 3.0 × 105/f | 9.0 × 105/f |
3 kHz ≤ f ≤ 10 MHz | 1.0 × 102 | 1.0 × 102 | 3.0 × 102 |
Exposure levels not exceeding the ALs will be compliant with: | At and below 400 Hz: the sensory effect ELVs in Table ELV3 | The health effect ELVs in Table ELV2 | |
Above 400 Hz: the health effect ELVs in Table ELV2 |
NOTES
1. Between the Low and High ALs for exposure up to 400 Hz, exposure in the head of the worker will be below the health effect ELVs but may exceed the sensory effect ELVs in Table ELV3.U.K.
2. Notes 2 and 3 to Table AL1 apply.U.K.
Frequency Range | External electric field strength ALs (E) [Vm-1] | Magnetic flux density ALs (B) [µT] | Power density ALs (S) [Wm-2] |
---|---|---|---|
100 kHz ≤ f < 1 MHz | 6.1 × 102 | 2.0 × 106/f | - |
1 ≤ f < 10 MHz | 6.1 × 108/f | 2.0 × 106/f | - |
10 ≤ f < 400 MHz | 61 | 0.2 | - |
400 MHz ≤ f < 2 GHz | 3.0 × 10-3 f½ | 1.0 × 10-5 f½ | - |
2 ≤ f < 6 GHz | 1.4 × 102 | 4.5 × 10-1 | - |
6 ≤ f ≤ 300 GHz | 1.4 × 102 | 4.5 × 10-1 | 50 |
Exposure levels not exceeding the ALs will be compliant with: | Up to 6 GHz: the health effect ELVs in Table ELV4 6 to 300 GHz: the health effect ELV in Table ELV6 | The health effect ELV in Table ELV6 |
NOTES
1. The electric field strength and magnetic flux density ALs are root mean square values.U.K.
2. For radiofrequency pulses, the peak power density averaged over the pulse width must not exceed 1000 times the respective AL (S) value. For multi-frequency fields, the analysis must be based on summation.U.K.
3. Note 3 to Table AL1 applies in relation to the ALs for electric field strength and magnetic flux density.U.K.
4. The power density is the maximum level averaged over any 20cm2 of exposed area. Spatial maximum power densities averaged over 1cm2 must not exceed 20 times the value of 50 Wm-2.U.K.
5. From 6 to 10 GHz, power density must be averaged over a six minute period. Above 10 GHz, it must be averaged over a 68/f1.05-minute period (where f is the frequency in GHz).U.K.
Frequency range | Limb current AL (IL) [mA] |
---|---|
10 ≤ f ≤ 110 MHz | 100 |
Exposure levels not exceeding the ALs will be compliant with: | The health effect ELV in table ELV4 - localised SAR in the limbs |
NOTE
The AL is a root mean square value.
Area of exposure | Sensory effect ELVs –magnetic flux density (B0) [T] |
---|---|
Head and Trunk | 2 |
Limbs | 8 |
Health effect ELV –magnetic flux density (B0) [T] | |
Any part of the body | 8 |
NOTE
The sensory effect ELVs may be exceeded during a worker’s shift where the employer ensures that—
(a)they are only exceeded temporarily;
(b)protection measures have been adopted which minimise, so far as is reasonably practicable, the sensory effects related to movement in static magnetic fields, including nausea and vertigo;
(c)adequate information is provided to the worker on the possibility of those sensory effects; and
(d)where any of those sensory effects are reported to the employer, the exposure assessment under regulation 6 and the protection measures are updated where necessary.
Frequency range | Health effect ELVs – internal electric field strength (E) [Vm-1] |
---|---|
1 Hz ≤ f < 3 kHz | 1.1 |
3 kHZ ≤ f ≤ 10 MHz | 3.8 × 10-4 f |
NOTES
1. The ELVs are limits for electric fields induced in the body from exposure to time-varying electric and magnetic fields.U.K.
2. The ELVs are spatial peak values in the entire body of the worker.U.K.
3. Note 2 to Table AL1 applies in relation to methods of determining exposure.U.K.
Frequency range | Sensory effect ELVs- internal electric field strength (E) [Vm-1] |
---|---|
1 ≤ f < 10 Hz | 0.7/f |
10 ≤ f < 25 Hz | 0.07 |
25 ≤ f ≤ 400 Hz | 0.0028 f |
NOTES
1. The ELVs are spatial peak values induced in the head of the exposed worker, and can arise from exposure to either external electric or external magnetic fields.U.K.
2. The ELVs may be exceeded during a worker’s shift where the employer ensures that—U.K.
(a)they are only exceeded temporarily;
(b)hazardous spark discharges and contact currents in excess of those in Table AL5 are prevented through the provision of information and training under regulation 19 and the use of suitable technical and personal protection measures;
(c)adequate information is provided to the worker on the possibility of sensory effects related to time-varying magnetic fields, including retinal phosphenes; and
(d)where any of those sensory effects are reported to the employer, the risk assessment is updated where necessary.
3. Note 2 to Table AL1 applies in relation to methods of determining exposure.U.K.
Area of exposure | Health effect ELVs – specific energy absorption rate (SAR)[ Wkg-1] |
---|---|
Whole body | 0.4 (averaged SAR in the body) |
Head and trunk | 10 (averaged SAR in the head and trunk) |
Limbs | 20 (averaged SAR in the limbs) |
NOTES
1. The ELVs correspond to the SAR values averaged over a six minute period.U.K.
2. Localised SAR in the body and limbs can be assessed by either computational dosimetry or physical measurement of 10g of tissue. For computational dosimetry, 10 grams of contiguous tissue with approximately homogeneous electrical properties must be used for the SAR average. For direct physical measurements, a simple geometry, such as cubic or spherical tissue mass, may be used. The maximum value obtained must be assessed against the ELVs.U.K.
Frequency range | Sensory effect ELV - specific energy absorption in the head (SA)[ mJkg-1] |
---|---|
300 MHz ≤ f ≤ 6 GHz | 10 |
NOTES
1. When determining SA, energy absorption must be averaged over 10 grams of tissue.U.K.
2. The ELV may be exceeded during a worker’s shift where the employer ensures that—U.K.
(a)it is only exceeded temporarily;
(b)adequate information is provided to the worker on the possibility of sensory effects related to pulsed microwave radiation, including auditory sensations; and
(c)where any of those sensory effects are reported to the employer, the risk assessment is updated where necessary.
Frequency range | Health effect ELVs - power density (S)[ Wm-2] |
---|---|
6 GHz ≤ f ≤ 300 GHz | 50 |
NOTES
1. The power density is the maximum level averaged over any 20cm2 of exposed area. Spatial maximum power densities averaged over 1cm2 must not exceed 20 times the value of 50 Wm-2.U.K.
2. From 6 to 10 GHz, power density must be averaged over a six-minute period. Above 10 GHz, it must be averaged over a 68/f1.05 -minute period (where f is the frequency in GHz).U.K.
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys