There are currently no known outstanding effects for the The Building (Higher-Risk Buildings Procedures) (England) Regulations 2023, Paragraph 4. Help about Changes to Legislation

October 2023 to April 2024: cases of not sufficiently progressed work where an initial notice is cancelled before 6th April 2024E+W

This adran has no associated Memorandwm Esboniadol

4.—(1) This paragraph applies where—

(a)the initial notice for the work, or the part of that notice which relates to the higher-risk building, ceases to be in force by virtue of any provision of Part 2 of the 1984 Act (except section 52(5)) on a date before 6th April 2024 (“the cancellation date”), and

(b)a notice under paragraph 1(4) (notice that work had sufficiently progressed) in relation to that work was not received by a local authority before the cancellation date.

(2) Where this paragraph applies—

(a)if a plans certificate or final certificate relating to the work (or any part of the work) has been accepted before the cancellation date then with effect from that date the certificate ceases to have effect;

(b)accordingly Parts 2 to 6 of these Regulations apply to the work from the cancellation date with the modifications provided for in paragraph (8);

(c)subject to paragraph (d), the 2010 Regulations, to the extent they apply to higher-risk buildings, apply to any of the work from the cancellation date;

(d)regulation 11(3) of the 2010 Regulations does not apply and accordingly the regulator may exercise the power in section 8(3A) of the 1984 Act(1) to dispense with or relax any requirement of the 2010 Regulations.

(3) Where this paragraph applies then with effect from the cancellation date the regulator, and not the local authority for the area, is the building control authority in relation to the higher-risk building and accordingly the duties and functions of the regulator under section 91 of the 1984 Act apply in relation to the work to the higher-risk building (but not in relation to any other work specified in the initial notice).

(4) Where this paragraph applies, not more than five working days after the cancellation date the person which was shown on the initial notice as the approved inspector must—

(a)give a notice to the person intending to carry out the work explaining the initial notice, or such part of the initial notice which applies to the higher-risk building, is no longer in force and the effect of sub-paragraphs (2), (3) and (5), and

(b)give a copy of the notice to the local authority.

(5) Within 10 working days of the cancellation date the person intending to carry out the work must give a notice to the regulator setting out—

(a)their name, address, telephone number and (if available) email address;

(b)the location of the building;

(c)details of the work to be carried out;

(d)the height of the higher-risk building as determined in accordance with regulation 5 of the Higher-Risk Buildings (Descriptions and Supplementary Provisions) Regulations 2023;

(e)the number of storeys in the higher-risk building as determined in accordance with regulation 6 of the Higher-Risk Buildings (Descriptions and Supplementary Provisions) Regulations 2023, and

(f)a description of any work which was carried out before the cancellation date (including details of the work in relation to which a final certificate was given and not rejected) and details of any inspections undertaken by the approved inspector in relation to that work.

(6) With effect from the cancellation date no further building work in relation to the work described in the initial notice (“HRB project”) may be carried out until the date when the person intending to carry out building work has received confirmation in writing from the regulator that an application for building control approval made to the regulator in relation to that work is valid (“validation date”).

(7) Where any building work was carried out before the cancellation date then—

(a)the person who carried out the work or the owner must comply with any notice from the regulator requiring them within a reasonable time to cut into, lay open or pull down so much of the work as prevents the regulator from ascertaining whether the work contravenes any requirement of the building regulations;

(b)in addition to the other documents which are required to accompany the application for building control approval, the person must provide the regulator with such plans as are necessary to show the work already carried out complies with all applicable requirements of the building regulations.

(8) Where the application for building control approval in relation to the HRB project is rejected by the regulator then with effect from the date the rejection is notified to the applicant (“rejection date”) no further building work in relation to the HRB project may be carried out until a building control approval is granted in relation to the building.

(9) Parts 2 to 6 of these Regulations have effect in relation to the HRB project—

(a)from the cancellation date as if—

(i)regulation 5(1)(b) (building control applications: for HRB work or stage of HRB work: validity and time limit) and regulation 13(1)(b) (building control applications: for work to existing HRB: validity and time limit) were omitted;

(ii)in relation to any change control which is proposed or occurs between the cancellation date and the date application for building control approval is determined by the regulator, Part 3 (change control) required the change to be recordable in the change control log;

(iii)regulation 47 (regularisation) does not apply in relation to any work carried out before the cancellation date and accordingly any reference to a regularisation certificate in Parts 2 to 6 of these Regulations in relation to such work is to be ignored;

(iv)regulations 50 to 56 (section 30A applications) did not apply in relation to the application for building control approval for the HRB project, and

(b)additionally, from the validation date until the rejection date, as if regulation 3 did not prevent work in the HRB project to be started before an application for building control approval for the work is submitted.

Commencement Information

I1Sch. 3 para. 4 in force at 1.10.2023, see reg. 1(1)

(1)

Subsection (3A) was inserted by paragraph 11(4) of Schedule 5 to the Building Safety Act 2022 (c. 30).

Yn ôl i’r brig