Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
Regulation 10
Textual Amendments
F1Schs. 3-5 inserted (31.12.2020) by The Food and Feed Regulated Products (Miscellaneous Amendments) (Wales) (EU Exit) Regulations 2019 (S.I. 2019/425), reg. 1(3), Sch.; 2020 c. 1, Sch. 5 para. 1(1)
Modifications etc. (not altering text)
C1Sch. 4 applied in part (with modifications) (N.I.) (1.10.2023) by The Windsor Framework (Retail Movement Scheme: Public Health, Marketing and Organic Product Standards and Miscellaneous Provisions) Regulations 2023 (S.I. 2023/959), regs. 1(2), 4(b), Sch. 2 (with regs. 7, 8)
1. Object and field of applicationE+W
The method allows the specific migration of lead and/or cadmium to be determined.
2. PrincipleE+W
The determination of the specific migration of lead and/or cadmium is carried out by an instrumental method of analysis that fulfils the performance criteria of paragraph 4.
3. ReagentsE+W
All reagents must be of analytical quality, unless otherwise specified.
Where reference is made to water, it means distilled water or water of equivalent quality.
(a)4 % (v/v) acetic acid, in aqueous solution
Add 40 ml of glacial acetic acid to water and make up to 1 000 ml.
(b)Stock solutions
Prepare stock solutions containing 1 000 mg/litre of lead and at least 500 mg/litre of cadmium respectively in a 4 % acetic acid solution, as referred to in sub-paragraph (a).
4. Performance criteria of the instrumental method of analysisE+W
(a)The detection limit for lead and cadmium must be equal to or lower than— 0,1 mg/litre for lead, 0,01 mg/litre for cadmium.
The detection limit is defined as the concentration of the element in the 4 % acetic acid solution, as referred to in paragraph 3(a), which gives a signal equal to twice the background noise of the instrument.
(b)The limit of quantification for lead and cadmium must be equal to or lower than— 0,2 mg/litre for lead, 0,02 mg/litre for cadmium.
(c)Recovery. The recovery of lead and cadmium added to the 4 % acetic acid solution, as referred to in paragraph 3(a), must lie within 80-120 % of the added amount.
(d)Specificity. The instrumental method of analysis used must be free from matrix and spectral interferences.
5. MethodE+W
(a)Preparation of the sample
The sample must be clean and free from grease or other matter likely to affect the test.
Wash the sample in a solution containing a household liquid detergent at a temperature of approximately 40 °C. Rinse the sample first in tap water and then in distilled water or water of equivalent quality. Drain and dry the sample so as to avoid any stain. The surface to be tested is not to be handled after it has been cleaned.
(b)Determination of lead and/or cadmium
The sample thus prepared is tested under the conditions laid down in Schedule 3.
Before taking the test solution for determining lead and/or cadmium, homogenise the content of the sample by an appropriate method, which avoids any loss of solution or abrasion of the surface being tested.
Carry out a blank test on the reagent used for each series of determinations.
Carry out determinations for lead and/or cadmium under appropriate conditions.]
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area. The revised version is currently only available in English.
Original (As Enacted or Made) - English: The original English language version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Original (As Enacted or Made) - Welsh:The original Welsh language version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: