On receipt of the samples, laboratories shall check the information recorded by the sampler on the sampling form and complete the relevant sections of that form. All samples received shall be examined to ensure that the packaging used for transportation is intact before storing. Samples received at a temperature higher than 8 °C shall be rejected unless the temperature at retail was higher than 8 °C.
Without prejudice to point 1.2, all samples are kept refrigerated until the end of their shelf-life.
In cases where samples must be stored until the end of their shelf-life, they shall be refrigerated:
at the storage temperature indicated on the label of the packaging. If the label indicates a temperature interval, the sample must be stored at the upper limit of the temperature interval;
if there is no specific storage temperature indicated on the label of the packaging, the sample must be kept at:
the maximum refrigeration temperatures defined by the legislation or guidance in force in the Member State where the sample is collected, with a tolerance of ± 2 °C,
8 °C (± 2 °C) where no such legislation or guidance exists.
If the shelf-life of the product sampled ends during a weekend or a national holiday, the sample must be analyzed on the last working day before the end of the shelf-life.
One of the two samples is analyzed within 24 hours from the time of arrival at the laboratory. If that sample is not analysed immediately upon arrival, it must be kept refrigerated at 3 °C (± 2 °C) in the laboratory before analysis.
The second sample shall be kept refrigerated until the end of its shelf-life.