Commission Decision
of 9 February 2010
establishing the classes of reaction-to-fire performance for certain construction products as regards decorative wallcoverings in roll and panel form
(notified under document C(2010) 397)
(Text with EEA relevance)
(2010/82/EU)
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Whereas:
With respect to the essential requirement of safety in the event of fire, interpretative document No 2 lists a number of interrelated measures which together define the fire safety strategy to be variously developed in the Member States.
Interpretative document No 2 identifies one of those measures as the limitation of the generation and spread of fire and smoke within a given area by limiting the potential of construction products to contribute to the full development of a fire.
The level of that limitation may be expressed only in terms of the different levels of reaction-to-fire performance of the products in their end-use application.
In the case of decorative wallcoverings in roll and panel form it is necessary to use the classification established in Decision 2000/147/EC.
The reaction-to-fire performance of many construction products and/or materials, within the classification provided for in Decision 2000/147/EC, is well established and sufficiently well known to fire regulators in Member States that they do not require testing for this particular performance characteristic.
The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,
HAS ADOPTED THIS DECISION:
Article 1
The construction products and/or materials which satisfy all the requirements of the performance characteristic ‘reaction-to-fire’ without need for further testing are set out in the Annex.
Article 2
The specific classes to be applied to different construction products and/or materials, within the reaction-to-fire classification adopted in Decision 2000/147/EC, are set out in the Annex to this Decision.
Article 3
Products shall be considered in relation to their end-use application, where relevant.
Article 4
This Decision is addressed to the Member States.
Done at Brussels, 9 February 2010.
For the Commission
Günter Verheugen
Vice-President
ANNEX
The table set out in this Annex lists construction products and/or materials which satisfy all of the requirements for the performance characteristic ‘reaction-to-fire’ without need for testing.
Product4 | Maximum mass per unit area(g/m2) | Maximum thickness(mm) | Class5 |
---|---|---|---|
Wallcoverings on cellulose fibre base | 190 | 0,9 | D-s3,d2 |
Wallcoverings on cellulose fibre base and polymer coated or printed | 470 | 0,7 | |
Wallcoverings on a mixture of cellulose and polyester fibre base | 160 | 0,3 | |
Wallcoverings on a mixture of cellulose and polyester fibre base and polymer coated or printed | 410 | 0,5 | |
Wallcoverings on a polymer coated fabric base | 510 | 0,7 | |
Wallcoverings of woven textile with a backing consisting of cellulose fibre or cellulose and polyester fibre | 450 | 0,8 | |
Wallcoverings of foamed PVC with a backing consisting of cellulose fibre or cellulose and polyester fibre | 310 | 1,8 |