[F1ANNEX III U.K. TYPE I TEST (Verifying the average emission of tailpipe emissions after a cold start)

Appendix 8 CALCULATION OF THE EMISSION OF POLLUTANTS

1. GENERAL U.K.

1.2. Volume determination U.K.
1.2.1. Calculation of the volume when a variable dilution device with constant flow control by orifice or venturi is used. Record continuously the parameters showing the volumetric flow, and calculate the total volume for the duration of the test. U.K.
1.2.2. Calculation of volume when a positive displacement pump is used. The volume of diluted exhaust gas in systems comprising a positive displacement pump is calculated with the following formula: U.K.

where:

V

=

volume of the diluted exhaust gas expressed in litres per test (prior to correction),

V o

=

volume of gas delivered by the positive displacement pump on testing conditions in litres per revolution,

N

=

number of revolutions per test.

1.2.3. Correction of the diluted exhaust-gas volume to standard conditions. The diluted exhaust-gas volume is corrected by means of the following formula: U.K.

( 2 )

in which:

( 3 )

where:

P B

=

barometric pressure in the test room in kPa,

P 1

=

vacuum at the inlet to the positive displacement pump in kPa relative to the ambient barometric pressure,

T p

=

average temperature of the diluted exhaust gas entering the positive displacement pump during the test (K).]