ANNEX [F1VI] U.K.CHARACTERISTICS OF OPACIMETERS

4.EFFECTIVE LENGTH ā€˜Lā€™ OF THE OPACIMETERU.K.

4.1.GeneralU.K.

4.1.1.In some types of opacimeter the gas between the light source and the photoelectric cell, or between transparent parts protecting the source and the photoelectric cell, is not of constant opacity. In such cases the effective length L shall be that of a column of gas of uniform opacity which gives the same absorption of light as that obtained when the gas is admitted in a normal way into the opacimeter.U.K.
4.1.2.The effective length of the light path is obtained by comparing the reading N of the opacimeter operating normally with the reading No obtained with the opacimeter modified so that the test gas fills a well defined length Lo.U.K.
4.1.3.It will be necessary to take comparative readings in quick succession to determine the correction to be made for shifts of zero.U.K.