xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"
Article 6a. Stability requirements and phasing-out of ro-ro passenger ships
Article 6b. Safety requirements for persons with reduced mobility
Article 7.Additional safety requirements, equivalents, exemptions and safeguard measures
SAFETY REQUIREMENTS FOR NEW AND EXISTING PASSENGER SHIPS ENGAGED ON DOMESTIC VOYAGES
CONSTRUCTION — SUBDIVISION AND STABILITY, MACHINERY AND ELECTRICAL INSTALLATIONS
PART A GENERAL 1 Definitions relating to Part B (R 2) NEW...
PART B INTACT STABILITY, SUBDIVISION AND DAMAGE STABILITY 1 Intact stability Resolution...
INTACT STABILITY, SUBDIVISION AND DAMAGE STABILITY
1 Intact stability Resolution A.749 (18)
7 Special requirements concerning ship subdivision (R 7)
8 Stability in damaged conditions (R 8)
NEW CLASS B, C AND D AND EXISTING CLASS B...
.1.1 Sufficient intact stability shall be provided in all service conditions...
.1.2 Where two adjacent main compartments are separated by a bulkhead...
.1.3 Where the required factor of subdivision is 0,50, the intact...
.2.1 The requirements of subparagraph .1 shall be determined by calculations which...
NEW CLASS B, C AND D AND EXISTING CLASS B...
.3 For the purpose of making damaged stability calculations the volume...
.5 Unsymmetrical flooding is to be kept to a minimum consistent...
.9 Each ship shall have scales of draughts marked clearly at...
.11 No relaxation from the requirements for damage stability may be...
.12 Relaxations from the requirements for damage stability shall be permitted...
8-1 Stability of ro-ro passenger ships in damaged conditions (R 8-1)
8-2 Special requirements for ro-ro passenger ships carrying 400 persons or more...
8-3 Special requirements for passenger ships, other than ro-ro passenger ships,...
9 Peak and machinery space bulkheads (R 10)
NEW CLASS B, C AND D AND EXISTING CLASS B...
.1 A forepeak or collision bulkhead shall be fitted which shall...
.2 Where any part of the ship below the waterline extends...
.3 Where a long forward superstructure is fitted, the forepeak or...
.4 The extension required in paragraph 3 need not be fitted...
.5 Ramps not meeting the above requirements shall be disregarded as...
.6 In existing class B ships, the requirements of paragraph .3 and...
.7 An afterpeak bulkhead, and bulkheads dividing the machinery space, from...
.8 In all cases stern tubes shall be enclosed in watertight...
11 Assigning, marking and recording of subdivision load lines (R 13)
NEW CLASS B, C AND D AND EXISTING CLASS B...
.1 In order that the required degree of subdivision shall be...
.2 The subdivision load lines assigned and marked shall be recorded...
.3 The freeboard corresponding to each of these load lines shall...
.4 The freeboard corresponding to each approved subdivision load line and...
.6 Whatever may be the position of the subdivision load line...
12 Construction and initial testing of watertight bulkheads, etc. (R 14)
NEW CLASS B, C AND D AND EXISTING CLASS B...
.1 Each watertight subdivision bulkhead, whether transverse or longitudinal, shall be...
.2.1 Steps and recesses in bulkheads shall be watertight and as...
.2.2 Where frames or beams pass through a watertight deck or...
.3 Testing main compartments by filling them with water is not...
.4 The forepeak, double bottoms (including duct keels) and inner skins...
.5 Tanks which are intended to hold liquids, and which form...
13 Openings in watertight bulkheads (R 15)
NEW CLASS B, C AND D AND EXISTING CLASS B...
.1 The number of openings in watertight bulkheads shall be reduced...
.2.1 Where pipes, scuppers, electrical cables, etc., are carried through watertight...
.2.2 Valves not forming part of a piping system shall not...
.2.3 Lead or other heat sensitive materials shall not be used...
.3.2 Except as provided in paragraph .3.3, the collision bulkhead may be...
.4 Within spaces containing the main and auxiliary propulsion machinery including...
NEW CLASS B, C AND D SHIPS OF 24 METRES IN...
.7.5 As far as practicable, electrical equipment and components for watertight...
.7.6 The enclosures of electrical components necessarily situated below the bulkhead...
.7.7 Electric power, control, indication and alarm circuits shall be protected...
.7.8 A single electrical failure in the power operating or control...
.8.1 The central operating console at the navigating bridge shall have...
.8.2 The central operating console at the navigating bridge shall be...
14 Ships carrying goods vehicles and accompanying personnel (R 16)
15 Openings in the shell plating below the margin line (R...
NEW CLASS B, C AND D AND EXISTING CLASS B...
.2 .1The arrangement and efficiency of the means for closing any...
.2.2 Subject to the requirements of the International Convention of the...
.2.5 Sidescuttles and their deadlights which will not be accessible during...
.3 The number of scuppers, sanitary discharges and other similar openings...
.4 All inlets and discharges in the shell plating shall be...
.4.1 Subject to the requirements of the International Convention on Load...
.4.2 The requirements of the International Convention on Load Lines in...
.5 Machinery space main and auxiliary sea inlets and discharges in...
.6 All shell fittings and valves required by this regulation shall...
.7 Gangway, and cargo ports fitted below the margin line shall...
16 Watertight integrity of passenger ships above the margin line (R...
17 Closure of cargo loading doors (R 20-1)
17-1 Watertight integrity from the ro-ro deck (bulkhead deck) to spaces...
NEW CLASS B, C AND D RO-RO PASSENGER SHIPS:
.1.1 Subject to the provisions of paragraphs .1.2 and .1.3, all accesses...
.1.2 where vehicle ramps are installed to give access to spaces...
.1.3 the Administration of the flag State may permit the fitting...
.1.4 the accesses referred to in paragraphs .1.2 and .1.3 shall be...
.1.5 the master shall ensure that an effective system of supervision...
.1.6 the master shall ensure, before the ship leaves the berth...
18 Stability information (R 22)
20 Integrity of the hull and superstructure, damage prevention and control...
21 Marking, periodical operation and inspection of watertight doors, etc. (R...
PART C MACHINERY 1 General (R 26) NEW CLASS B, C AND...
3 Bilge pumping arrangement (R 21)
NEW CLASS B, C AND D AND EXISTING CLASS B...
.2.1 The bilge pumping system required by paragraph .1.1 shall be capable...
.2.2 Where practicable, the power bilge pumps shall be placed in...
.2.3 With the exception of additional pumps which may be provided...
.2.4 Each power bilge pump shall be capable of pumping water...
.2.5 In addition to the direct bilge suction or suctions required...
.2.6 The spindles of the sea inlet and direct suction valves...
.2.7 All bilge suction piping up to the connection to the...
.2.8 The diameter ‘d’ of the main and branch bilge suction...
.2.9 Provision shall be made to prevent the compartment served by...
.2.10 Distribution boxes, cocks and valves in connection with the bilge...
.2.11 All cocks and valves referred to in paragraph .2.10 which can...
7 Additional requirements for electric and electro-hydraulic steering gear (R 30)...
9 Communication between the navigating bridge and machinery space (R 37)...
.1 Main and auxiliary machinery essential for the propulsion and the...
.2 Where remote control of propulsion machinery from the navigating bridge...
.3 Where the main propulsion and associated machinery, including sources of...
.4 In general, automatic starting, operational and control systems shall include...
14 Air pressure systems (R 34)
PART D ELECTRICAL INSTALLATIONS 1 General (R 40) NEW CLASS B, C AND D AND...
2 Main source of electrical power and lighting (R 41)
3 Emergency source of electrical power (R 42)
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
.1 Every ship shall be provided with a self-contained emergency source...
.2 The emergency source of electric power may be either an...
.3 The emergency source of electric power shall be so arranged...
.4 The emergency switchboard shall be situated as near as practicable...
.5 The emergency source of power required by paragraph .1 shall:
.6 The transitional source of emergency electrical power required by paragraph .2...
.7 CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY 2003...
5 Precautions against shock, fire and other hazards of electrical origin...
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
.1 Exposed metal parts of electrical machines or equipment which are...
.2 All electrical apparatus shall be so constructed and so installed...
.3 The sides and the rear and, where necessary, the front...
.4 In distribution systems with no connection to earth, a device...
.5.1 All metal sheaths and armour of cables shall be electrically...
.5.2 All electrical cables and wiring external to equipment shall be...
ADDITIONAL REQUIREMENTS FOR PERIODICALLY UNATTENDED MACHINERY SPACES
4 Control of propulsion machinery from the navigating bridge (R 49)
.1 Under all sailing conditions, including manœuvring, the speed, direction of...
.2 Propulsion machinery orders from the navigating bridge shall be indicated...
.3 Remote control of the propulsion machinery shall be possible only...
.4 It shall be possible for all machinery essential for the...
.5 The design of the remote automatic control system shall be...
.7 The number of consecutive automatic attempts which fail to produce...
8 Special requirements for machinery, boiler and electrical installations (R 53)
9 Automatic control and alarm system (R 53.4)
FIRE PROTECTION, FIRE DETECTION AND FIRE EXTINCTION
PART A GENERAL 1 Basic principles (R 2) NEW CLASS B, C AND D AND...
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
.1 Non-combustible material is a material which neither burns nor gives...
.1.a FOR B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY...
.2a. FOR CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY...
.5 ‘ C ’ class divisions are divisions constructed of approved...
.7 Steel or other equivalent material . Where the words ‘steel...
.8 Low flame spread means that the surface thus described will...
.9 Main vertical zones are those sections into which the hull,...
.10 Accommodation spaces are those spaces used for public spaces, corridors,...
.11 Public spaces are those portions of the accommodation which are...
.12 Service spaces are those spaces used for galleys, pantries containing...
.13 Cargo spaces are all spaces used for cargo (including cargo...
.13-1 Vehicle spaces are cargo spaces intended for the carriage of...
.14 Ro-ro cargo spaces are spaces not normally subdivided in any...
.15 Open ro-ro cargo spaces are ro-ro cargo spaces either open...
.15-1 Open vehicle spaces are those vehicle spaces either open at...
.16 Closed ro-ro cargo spaces are ro-ro cargo spaces which are...
.16-1 Closed vehicle spaces are vehicle spaces which are neither open...
.17 Weather deck is a deck which is completely exposed to...
.18 Special category spaces are those enclosed vehicle spaces above or...
.19.1 Machinery spaces of category A are those spaces and trunks to...
.19.2 Machinery spaces are all machinery spaces of category A and all...
.20 Oil fuel unit is the equipment used for the preparation...
.21 Control stations are those spaces in which the ship's radio...
.21.1 Central control station is a control station in which the...
.21.2 Continuously manned central control station is a central control station...
.22 Rooms containing furniture and furnishings of restricted fire risk are,...
.23 Ro-ro passenger ship means a passenger ship with ro-ro cargo...
.24 Fire Test Procedures Code means the International Code for Application...
.25 Fire Safety Systems Code means the International Code for Fire...
.26 Flashpoint is the temperature in degrees Celsius (closed cup test)...
.27 Prescriptive requirements mean the constructive characteristics, limiting dimensions or fire...
3 Fire pumps, fire mains, hydrants, hoses and nozzles (R 4)
NEW CLASS B, C AND D SHIPS, CONSTRUCTED BEFORE 1 JANUARY 2003 :...
NEW CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY...
ALL NEW AND EXISTING CLASS B SHIPS AND NEW CLASS C AND...
.3 Arrangements of fire pumps, fire mains and ready availability of...
.1 Ships shall be provided with power driven fire pumps as...
.2 Sanitary, ballast, bilge or general service pumps may be accepted...
.3 The arrangement of sea connections, fire pumps and their sources...
.4 In new class B ships certified to carry more than 250 passengers,...
.5 In ships with a periodically unattended machinery space or when...
NEW CLASS C AND D SHIPS OF LESS THAN 24 METRES...
.9 Fire pumps, fire mains, hydrants, hoses, nozzles and ready availability...
4 Fixed fire-extinguishing systems (R 5 + 8 + 9 + 10)
.1 Fixed gas fire-extinguishing systems: General (R 5.1)
NEW CLASS B, C AND D SHIPS, CONSTRUCTED BEFORE 1 JANUARY...
.1 The necessary pipes for conveying fire-extinguishing medium into protected spaces...
.2 The piping for the distribution of fire-extinguishing medium shall be...
.3 Means shall be provided to close from outside the protected...
.4 Means shall be provided for automatically giving audible warning of...
.5 The means of control of any fixed gas fire-extinguishing system...
.6 Automatic release of fire-extinguishing medium shall not be permitted, except...
.7 Where the quantity of extinguishing medium is required to protect...
.8 Except as otherwise permitted, pressure containers required for the storage...
.9 Means shall be provided for the crew or shore personnel...
.10 Containers for the storage of fire extinguishing medium and associated...
.11 When the fire-extinguishing medium is stored outside a protected space,...
.12 The use of a fire-extinguishing medium, which either by itself...
NEW CLASS A, B, C AND D SHIPS AND EXISTING...
.16 Where the volume of free air contained in air receivers...
.17 Suppliers of fixed fire-extinguishing installations shall provide a description of...
.18 The quantity of the fire-extinguishing medium shall be checked at...
.19 The periodic checking which is carried out by the ship's...
.20 Non-prescribed fire extinguishing equipment which is installed e.g. in store...
.21 All doors to spaces protected by CO 2 /halon installation...
.3 Fixed low-expansion foam fire-extinguishing systems in machinery spaces (R 8)...
.4 Fixed high-expansion foam fire-extinguishing systems in machinery spaces (R 9)...
.5 Fixed pressure water-spraying fire-extinguishing systems in machinery spaces (R 10)...
NEW CLASS B, C AND D SHIPS CONSTRUCTED BEFORE 1 JANUARY...
.1 Any required fixed pressure water-spraying fire-extinguishing system in machinery spaces...
.2 The number and arrangement of the nozzles shall be such...
.3 The system may be divided into sections, the distribution valves...
.4 The system shall be kept charged at the necessary pressure...
.5 The pump shall be capable of simultaneously supplying at the...
.6 Precautions shall be taken to prevent the nozzles from becoming...
5 Portable fire extinguishers (R 6)
NEW CLASS B, C AND D SHIPS, CONSTRUCTED ON OR...
.5 Portable fire extinguishers shall comply with the provisions of the...
.6 Carbon dioxide fire extinguishers shall not be placed in accommodation...
.7 Fire extinguishers shall be situated ready for use at easily...
.8 Spare charges shall be provided for 100 % of the first...
.9 For the extinguishers which cannot be recharged on board, additional...
NEW CLASS B, C AND D AND EXISTING CLASS B...
.10 Fire extinguishers containing an extinguishing medium which either by itself...
.11 The fire extinguishers shall be suitable for extinguishing fires which...
.12 One of the portable fire extinguishers intended for use in...
.13 The minimum number of fire extinguishers shall be as follows:...
.14 Portable fire extinguishers provided for use in accommodation or service...
6 Fire-extinguishing arrangements in machinery spaces (R 7)
7 Special arrangements in machinery spaces (R 11)
8 Automatic sprinkler, fire detection and fire alarm systems (R 12)...
NEW CLASS B, C AND D SHIPS, CONSTRUCTED BEFORE 1 JANUARY...
.1 Any required automatic sprinkler, fire detection and fire alarm system...
.2 Each section of sprinklers shall include means for giving a...
.3 Sprinklers shall be grouped into separate sections, each of which...
.4 Each section of sprinklers shall be capable of being isolated...
.5 A gauge indicating the pressure in the system shall be...
.6 The sprinklers shall be resistant to corrosion by marine atmosphere....
.8 Sprinklers shall be placed in an overhead position and spaced...
.10 Means shall be provided to prevent the passage of seawater...
.11 An independent power pump shall be provided solely for the...
.17 The sprinkler system shall have a connection from the ship's...
.18 A test valve shall be provided for testing the automatic...
.19 Means shall be provided for testing the automatic operation of...
.20 Switches shall be provided at one of the indicating positions...
.21 At least 6 spare sprinkler heads shall be provided for...
9 Fixed fire detection and fire alarm systems (R 13)
NEW CLASS B, C AND D SHIPS, CONSTRUCTED BEFORE 1 JANUARY...
.1 Any required fixed fire detection and fire alarm system with...
.2 Power supplies and electric circuits necessary for the operation of...
.4 Detectors and manually operated call points shall be grouped into...
.5 The control panel shall be located on the navigating bridge...
.6 Indicating units shall, as a minimum, denote the section in...
.7 Clear information shall be displayed on or adjacent to each...
.8 Where the fire detection system does not include means of...
.9 If there is no fire detection system capable of remotely...
.10 A section of fire detectors which covers a control station,...
.11 Detectors shall be operated by heat, smoke or other products...
.12 Suitable instructions and component spares for testing and maintenance shall...
.13 The function of the detection system shall be periodically tested...
.15 Fire detection systems with a zone address identification capability shall...
.1 Manually operated call points shall be installed throughout the accommodation...
.2 Smoke detectors shall be installed in all stairways, corridors and...
.3 Where a fixed fire detection and fire alarm is required...
.4 Detectors shall be located for optimum performance. Positions near beams...
.5 The maximum spacing of detectors shall be in accordance with...
.6 Electrical wiring which forms part of the system shall be...
10 Arrangements for oil fuel, lubricating oil and other flammable oils...
NEW CLASS B, C AND D AND EXISTING CLASS B...
.2 The ventilation of machinery spaces shall be sufficient under all...
.5 Every oil fuel pipe, which, if damaged, would allow oil...
.6 Safe and efficient means of ascertaining the amount of oil...
.7 Provision shall be made to prevent overpressure in any oil...
NEW CLASS B, C AND D SHIPS, CONSTRUCTED ON OR...
.12 Oil fuel lines shall not be located immediately above or...
.13 Components of a diesel engine fuel system shall be designed...
.14 In multi-engine installations which are supplied from the same fuel...
.15 Where the Administration of the flag State may permit the...
.16 Existing class B ships shall comply with the requirements of...
NEW CLASS B, C AND D AND EXISTING CLASS B...
.1 Where class ‘A’ divisions are penetrated for the passage of...
.2 Where class ‘B’ divisions are penetrated for the passage of...
.3 Pipes penetrating ‘A’ or ‘B’ class divisions shall be of...
.4 In accommodation spaces, service spaces or control stations, pipes intended...
.5 Materials readily rendered ineffective by heat shall not be used...
.6 Electric radiators, if used, shall be fixed in position and...
.7 All waste receptacles shall be constructed of non-combustible materials with...
.8 In spaces where penetration of oil products is possible, the...
.9 Paint lockers and flammable liquid lockers shall be protected by...
15 Instructions, on-board training and drills
NEW CLASS B, C AND D AND EXISTING SHIPS:
PART B FIRE SAFETY MEASURES 1 Structure (R 23) NEW CLASS B, C...
2 Main vertical zones and horizontal zones (R 24)
3 Bulkheads within a main vertical zone (R 25)
4 Fire integrity of bulkheads and decks in new ships carrying...
5 Fire integrity of bulkheads and decks in new ships carrying...
NEW CLASS B, C AND D SHIPS AND EXISTING CLASS B SHIPS:
.1 Stairways and ladders, corridors and doors shall be arranged to...
.5 NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS OF...
.1 Emergency escape breathing devices shall be carried, complying with the...
.2 At least two emergency escape breathing devices shall be carried...
.3 In ships carrying more than 36 passengers, two emergency escape breathing...
.4 However, subparagraphs .5.2 and .5.3 do not apply to stairway enclosures...
.5 Within the machinery spaces, emergency escape breathing devices shall be...
.6 Reference is made to the IMO Guidelines for the performance,...
.7 The number and location of these devices shall be indicated...
6-1 Escape routes on ro-ro passenger ships (R 28-1)
.1 REQUIREMENTS APPLICABLE TO NEW CLASS B, C AND D AND EXISTING...
.1.1 This paragraph applies to new class B, C and D and existing...
.1.2 Handrails or other handholds shall be provided in all corridors...
.1.3 Escape routes shall not be obstructed by furniture or other...
.1.4 Escape routes shall be provided from every normally occupied space...
.1.5 Where enclosed spaces adjoin an open deck, openings from the...
.1.6 Decks shall be sequentially numbered, starting with ‘ 1 ’...
.1.8 Cabin and stateroom doors shall not require keys to unlock...
.2 REQUIREMENTS APPLICABLE TO NEW CLASS B, C AND D RO-RO PASSENGER...
.2.1 The lowest 0,5 metres of bulkheads and other partitions forming vertical...
.2.2 The escape route from cabins to stairway enclosures shall be...
.2.3 External routes shall be provided from open decks, referred to...
.3 REQUIREMENTS APPLICABLE TO NEW CLASS B, C AND D RO-RO PASSENGER SHIPS...
7 Penetrations and openings in ‘A’ and ‘B’ class divisions (R 30,...
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
.4 Fire doors in main vertical zone bulkheads and stairways enclosures...
.1 The doors shall be self-closing and be capable of closing...
.2 Remote-controlled sliding or power-operated doors shall be equipped with an...
.3 All doors, except fire doors which are normally kept closed,...
.4 Local power accumulators for power-operated doors shall be provided in...
.5 Double-leaf doors equipped with a latch necessary to their fire...
.6 Doors giving direct access to special category spaces which are...
CLASS B, C AND D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2003...
CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY 2003...
8 Protection of stairways and lifts in accommodation and service spaces...
.1 Ships carrying more than 36 passengers
.2 Ships carrying not more than 36 passengers
.1 Ventilation ducts shall be of non-combustible material. Short ducts, however,...
.2a Where the ventilation ducts with a free-sectional area exceeding 0,02 m...
.2b In new class B, C and D ships, constructed on or after...
.3 Ducts provided for the ventilation of machinery spaces, galleys, car...
.4 Ducts provided for ventilation to accommodation spaces, service spaces or...
.5 Ventilation ducts with a free-sectional area exceeding 0,02 m 2 passing...
.6 Such measures as are practicable shall be taken in respect...
.7 Where they pass through accommodation spaces or spaces containing combustible...
.8 Where it is necessary that a ventilation duct passes through...
.3 ALL CLASS B,C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY...
11 Restricted use of combustible material (R 34)
.1 Except in cargo spaces, mail rooms, baggage rooms, or refrigerated...
.2 Vapour barriers and adhesives used in conjunction with insulation, as...
.3 The following surfaces shall have low flame-spread characteristics:
.4 The total volume of combustible facings, mouldings, decorations and veneers...
.5 Veneers used on surfaces and linings covered by the requirements...
.6 Furniture in stairway enclosures shall be limited to seating. It...
.7 Paints, varnishes and other finishes used on exposed interior surfaces...
CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY 2003...
CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JANUARY 2003...
13 Fixed fire detection and fire alarm systems and automatic sprinkler,...
14 Protection of special category spaces (R 37)
.1 Provisions applicable to special category spaces whether above or below...
NEW CLASS B, C AND D SHIPS AND EXISTING CLASS B SHIPS...
NEW CLASS B, C AND D, CONSTRUCTED BEFORE 1 January 2003 AND...
NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
.1 There shall be provided an effective power ventilation system for...
.2 The ventilation shall be such as to prevent air stratification...
.3 Means shall be provided to indicate on the navigating bridge...
.4 Arrangements shall be provided to permit a rapid shutdown and...
.5 Ventilation ducts, including dampers, shall be made of steel and...
.2 Additional provisions applicable only to special category spaces above the...
.3 Additional provisions applicable only to special category spaces below the...
15 Fire patrols, detection, alarms and public address systems (R 40)
16 Upgrading of existing class B ships carrying more than 36 passengers (R 41-1)...
17 Special requirements for ships carrying dangerous goods (R 41)
CHAPTER III LIFE SAVING APPLIANCES
3 Emergency alarm, operating instructions, training manual, assembly lists and emergency...
NEW AND EXISTING CLASS B, C AND D SHIPS:
.2 A public address system (R 6.5)
.2.1 In addition to the requirements of regulation II-2/B/15.4 and of paragraph .1,...
.2.2 The public address system shall be a loudspeaker installation enabling...
.2.3 The public address system shall be protected against unauthorised use...
.2.5 The public address system shall be connected to the emergency...
.2.6 Existing ships which are already fitted with the public address...
4 Manning of survival craft and supervision (R 10)
5 Survival craft assembly and embarkation arrangements (R 11 + 23 + 25)
NEW AND EXISTING CLASS B, C AND D SHIPS:
.1 Survival craft for which approved launching appliances are required shall...
.2 Assembly stations shall be provided close to the embarkation stations...
.3 Assembly and embarkation stations, alleyways, stairways and exits giving access...
.4 Lifeboats shall be capable of being boarded either directly from...
.5 Davit-launched life-raft shall be capable of being boarded from a...
.6 Where necessary means shall be provided for bringing the davit-launched...
5-3 Decision support system for masters (R 29)
NEW AND EXISTING CLASS B, C AND D SHIPS:
.1 Existing ships shall comply with the requirements of this regulation not...
.2 In all ships, a decision support system for emergency management...
.4 The emergency procedures established in the emergency plan or plans...
.5 The emergency plan or plans shall have a uniform structure...
.6 In addition to the printed emergency plan or plans the...
7 Stowage of survival craft (R 13 + 24 )
9 Survival craft launching and recovering arrangements (R 16)
NEW AND EXISTING CLASS B, C AND D SHIPS:
.1 Launching appliances complying with the requirements of section 6.1 of the...
.2 Each lifeboat shall be provided with an appliance which is...
.3 Launching and recovering arrangements shall be such that the appliance...
.5 Falls, where used, shall be long enough for survival craft...
.6 Preparation and handling of survival craft at any one launching...
.7 Means shall be available to prevent any discharge of water...
.8 During preparation and launching, the survival craft, its launching appliance,...
10 Rescue boat embarkation, launching and recovery arrangements (R 17)
12 Operational readiness, maintenance and inspections (R 20)
13 Abandon ship training and drills (R 19 + R 30)
NEW AND EXISTING CLASS B, C AND D SHIPS:
.1 Every crew member with assigned emergency duties shall be familiar...
.3 Each abandon ship drill shall include the actions required in...
.4 Lifeboats and rescue boats shall be lowered at successive drills...
.5 If a ship is fitted with marine evacuation systems drills...
.6 Emergency lighting for assembling and abandonment shall be tested at...
.7 Fire drills shall be carried out in accordance with the...
.8 On-board training and instructions shall be given to crew members...