Search Legislation

Directive 2001/83/EC of the European Parliament and of the CouncilShow full title

Directive 2001/83/EC of the European Parliament and of the Council of 6 November 2001 on the Community code relating to medicinal products for human use

 Help about what version

What Version

  • Latest available (Revised)
  • Original (As adopted by EU)
 Help about advanced features

Advanced Features

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.

[F11. BIOLOGICAL MEDICINAL PRODUCTS U.K.

1.1. Plasma-derived medicinal product U.K.

For medicinal products derived from human blood or plasma and by derogation from the provisions of Module 3, the dossier requirements mentioned in Information related to the starting and raw materials , for starting materials made of human blood/plasma may be replaced by a Plasma Master File certified in accordance with this Part.

a) Principles U.K.

For the purposes of this Annex:

  • Plasma Master File shall mean a stand-alone documentation, which is separate from the dossier for marketing authorisation which provides all relevant detailed information on the characteristics of the entire human plasma used as a starting material and/or a raw material for the manufacture of sub/intermediate fractions, constituents of the excipient and active substance(s), which are part of medicinal products or medical devices referred to in Directive 2000/70/EC of the European Parliament and of the Council of 16 November 2000 amending Council Directive 93/42/EC as regards medical devices incorporating stable derivatives of human blood or human plasma (1) .

  • Every centre or establishment for fractionation/processing of human plasma shall prepare and keep updated the set of detailed relevant information referred to in the Plasma Master File.

  • The Plasma Master File shall be submitted to the Agency or to the competent authority by the applicant for a marketing authorisation or the holder of the marketing authorisation. Where the applicant for a marketing authorisation or the marketing authorisation holder differs from the holder of the Plasma Master File, the Plasma Master File shall be made available to the applicant or marketing authorisation holder for submission to the competent authority. In any case, the applicant or marketing authorisation holder shall take responsibility for the medicinal product.

  • The competent authority that is evaluating the marketing authorisation shall await for the Agency to issue the certificate before deciding on the application.

  • Any marketing authorisation dossier containing a human plasma-derived constituent shall refer to the Plasma Master File corresponding to the plasma used as a starting/raw material.

b) Content U.K.

In accordance with the provisions of Article 109, as amended by Directive 2002/98/EC, which refers to the requirements for donors and the testing of donations, the Plasma Master File shall include information on the plasma used as starting/raw material, in particular:

(1)

Plasma origin

(i)

information on centres or establishments in which blood/plasma collection is carried out, including inspection and approval, and epidemiological data on blood transmissible infections.

(ii)

information on centres or establishments in which testing of donations and plasma pools is carried out, including inspection and approval status.

(iii)

selection/exclusion criteria for blood/plasma donors.

(iv)

system in place which enables the path taken by each donation to be traced from the blood/plasma collection establishment through to finished products and vice versa.

(2)

Plasma quality and safety

(i)

compliance with European Pharmacopoeia Monographs.

(ii)

testing of blood/plasma donations and pools for infectious agents, including information on test methods and, in the case of plasma pools, validation data on the tests used.

(iii)

technical characteristics of bags for blood and plasma collection, including information on anticoagulants solutions used.

(iv)

conditions of storage and transport of plasma.

(v)

procedures for any inventory hold and/or quarantine period.

(vi)

characterisation of the plasma pool.

(3)

System in place between the plasma-derived medicinal product manufacturer and/or plasma fractionator/processor on the one hand, and blood/plasma collection and testing centres or establishments on the other hand, which defines the conditions of their interaction and their agreed specifications.

In addition, the Plasma Master File shall provide a list of the medicinal products for which the Plasma Master File is valid, whether the medicinal products have been granted a marketing authorisation or are in the process of being granted such an authorisation, including medicinal products referred to in Article 2 of Directive 2001/20/EC of the European Parliament and of the Council relating to the implementation of good clinical practice in the conduct of clinical trials on medicinal products for human use.

c) Evaluation and Certification U.K.
  • For medicinal products not yet authorised, the marketing authorisation applicant shall submit a full dossier to a competent authority, which shall be accompanied by a separate Plasma Master File where one does not already exist.

  • The Plasma Master File is subject to a scientific and technical evaluation carried out by the Agency. A positive evaluation shall result in a certificate of compliance with Community legislation for the Plasma Master File, which shall be accompanied by the evaluation report. The certificate issued shall apply throughout the Community.

  • The Plasma Master File shall be updated and re-certified on an annual basis.

  • Changes subsequently introduced to the terms of a Plasma Master File must follow evaluation procedure laid down by Commission Regulation (EC) No 542/95 (2) concerning the examination of variations to the terms of a marketing authorisation falling within the scope of Council regulation (EEC) No 2309/93 of 22 July 1993 laying down Community procedures for the authorisation and supervision of medicinal products for human and veterinary use and establishing a European Agency for the Evaluation of Medicinal Products (3) . Conditions for the assessment of these changes are laid down by Regulation (EC) No 1085/2003.

  • As a second step to the provisions in the first, second, third and fourth indents, the competent authority that will grant or has granted the marketing authorisation shall take into account the certification, re-certification or variation of the Plasma Master File on the concerned medicinal product(s).

  • By derogation from the provisions of the second indent of the present point (evaluation and certification), where a Plasma Master File corresponds only to blood/plasma-derived medicinal products the marketing authorisation of which is restricted to a single Member State, the scientific and technical evaluation of the said Plasma Master File shall be carried out by the national competent authority of that Member State.

1.2. Vaccines U.K.

For vaccines for human use and by derogation from the provisions of Module 3 on Active substance(s) , the following requirements when based on the use of a Vaccine Antigen Master File system shall apply.

The marketing authorisation application dossier of a vaccine other than human influenza vaccine, shall be required to include a Vaccine Antigen Master File for every vaccine antigen that is an active substance of this vaccine.

a) Principles U.K.

For the purposes of this Annex:

  • Vaccine Antigen Master File shall mean a stand-alone part of the marketing authorisation application dossier for a vaccine, which contains all relevant information of biological, pharmaceutical and chemical nature concerning each of the active substances, which are part of this medicinal product. The stand-alone part may be common to one or more monovalent and/or combined vaccines presented by the same applicant or marketing authorisation holder.

  • A vaccine may contain one or several distinct vaccine antigens. There are as many active substance(s) as vaccine antigen(s) present in a vaccine.

  • A combined vaccine contains at least two distinct vaccine antigens aimed at preventing a single or several infectious diseases.

  • A monovalent vaccine is a vaccine, which contains one vaccine antigen aimed at preventing a single infectious disease.

b) Content U.K.

The Vaccine Antigen Master File shall contain the following information extracted from the relevant part (Active substance) of Module 3 on Quality Data as delineated in Part I of this Annex:

  • Active Substance

    1.

    General Information, including compliance with the relevant monograph(s) of the European Pharmacopoeia.

    2.

    Information on the manufacture of the active substance: this heading must cover the manufacturing process, information on the starting and raw materials, specific measures on TSEs and adventitious agents safety evaluation and facilities and equipment.

    3.

    Characterisation of the active substance

    4.

    Quality control of the active substance

    5.

    Reference standard and materials

    6.

    Container and closure system of the active substance

    7.

    Stability of the active substance.

c) Evaluation and Certification U.K.
  • For novel vaccines, which contain a novel vaccine antigen, the applicant shall submit to a competent authority a full marketing-authorisation application dossier including all the Vaccine Antigen Master Files corresponding to each single vaccine antigen that is part of the novel vaccine where no master file already exists for the single vaccine antigen. A scientific and technical evaluation of each Vaccine Antigen Master File shall be carried out by the Agency. A positive evaluation shall result in a certificate of compliance to the European legislation for each Vaccine Antigen Master File, which shall be accompanied by the evaluation report. The certificate shall apply throughout the Community.

  • The provisions of the first indent shall also apply to every vaccine, which consists of a novel combination of vaccine antigens, irrespective of whether or not one or more of these vaccine antigens are part of vaccines already authorised in the Community.

  • Changes to the content of a Vaccine Antigen Master File for a vaccine authorised in the Community shall be subject to a scientific and technical evaluation carried out by the Agency in accordance with the procedure laid down in Commission Regulation (EC) No 1085/2003. In the case of a positive evaluation the Agency shall issue a certificate of compliance with Community legislation for the Vaccine Antigen Master File. The certificate issued shall apply throughout the Community.

  • By derogation from the provisions of the first, second and third indents of the present point (evaluation and certification), where a Vaccine Antigen Master File corresponds only to a vaccine which is the subject of a marketing authorisation which has not been/will not be granted according to a Community procedure, and, provided the authorised vaccine includes vaccine antigens which have not been evaluated through a Community procedure, the scientific and technical evaluation of the said Vaccine Antigen Master File and its subsequent changes, shall be carried out by the national competent authority that has granted the marketing authorisation.

  • As a second step to the provisions in the first, second, third and fourth indents, the competent authority that will grant or has granted the marketing authorisation shall take into account the certification, re-certification or variation of the Vaccine Antigen Master File on the concerned medicinal product(s).]

Back to top

Options/Help

Print Options

You have chosen to open the Whole Directive

The Whole Directive you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

You have chosen to open Schedules only

The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources