ANNEX IIU.K.LABORATORY TESTS REQUIRED FOR DONORS (EXCEPT DONORS OF REPRODUCTIVE CELLS) AS REFERRED TO IN ARTICLE 4(1)

2.General requirements to be met for determining biological markersU.K.

2.1.The tests must be carried out by a qualified laboratory, authorised as a testing centre by the competent authority in the Member State, using EC-marked testing kits where appropriate. The type of test used must be validated for the purpose in accordance with current scientific knowledge.U.K.

2.2.The biological tests will be carried out on the donor’s serum or plasma; they must not be performed on other fluids or secretions such as the aqueous or vitreous humour unless specifically justified clinically using a validated test for such a fluid.U.K.

2.3.When potential donors have lost blood and have recently received donated blood, blood components, colloids or crystalloids, blood testing may not be valid due to haemodilution of the sample. An algorithm must be applied to assess the degree of haemodilution in the following circumstances:U.K.

(a) ante-mortem blood sampling

:

if blood, blood components and/or colloids were infused in the 48 hours preceding blood sampling or if crystalloids were infused in the hour preceding blood sampling;

(b) post-mortem blood sampling

:

if blood, blood components and/or colloids were infused in the 48 hours preceding death or if crystalloids were infused in the hour preceding death.

Tissue establishments may accept tissues and cells from donors with plasma dilution of more than 50 % only if the testing procedures used are validated for such plasma or if a pre-transfusion sample is available.

2.4.In the case of a deceased donor, blood samples must have been obtained just prior to death or, if not possible, the time of sampling must be as soon as possible after death and in any case within 24 hours after death.U.K.