Search Legislation

Directive 2006/7/EC of the European Parliament and of the CouncilShow full title

Directive 2006/7/EC of the European Parliament and of the Council of 15 February 2006 concerning the management of bathing water quality and repealing Directive 76/160/EEC

 Help about what version

What Version

 Help about advanced features

Advanced Features

More Resources

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.

ANNEX VU.K.Rules on the handling of samples for microbiological analyses

1.Sampling pointU.K.

Where possible, samples are to be taken 30 centimetres below the water's surface and in water that is at least one metre deep.

2.Sterilisation of sample bottlesU.K.

Sample bottles are:

  • to undergo sterilisation in an autoclave for at least 15 minutes at 121 oC, or

  • to undergo dry sterilisation at between 160 oC and 170 oC for at least one hour, or

  • to be irradiated sample containers obtained directly from manufacturer.

3.SamplingU.K.

The volume of the sampling bottle/container is to depend on the quantity of water needed for each parameter to be tested. The minimum content is generally 250 ml.

Sample containers are to be of transparent and non-coloured material (glass, polyethene or polypropylene).

In order to prevent accidental contamination of the sample, the sampler is to employ an aseptic technique to maintain the sterility of the sample bottles. There is no further need for sterile equipment (such as sterile surgical gloves or tongs or sample pole) if this is done properly.

The sample is to be clearly identified in indelible ink on the sample and on the sampling form.

4.Storage and transport of samples before analysisU.K.

Water samples are to be protected at all stages of transport from exposure to light, in particular direct sunlight.

The sample is to be conserved at a temperature of around 4 oC, in a cool box or refrigerator (depending on climate) until arrival at the laboratory. If the transport to the laboratory is likely to take more than four hours, then transport in a refrigerator is required.

The time between sampling and analysis is to be kept as short as possible. It is recommended that samples be analysed on the same working day. If this is not possible for practical reasons, then the samples shall be processed within no more than 24 hours. In the meantime, they shall be stored in the dark and at a temperature of 4 oC ± 3 oC.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources