Article 6.07Indicators and monitoring devices
1.The rudder position shall be clearly displayed at the steering position. If the rudder-position indicator is electric it shall have its own power supply.
2.There shall be at least the following indicators and monitoring devices at the steering position:
(a)oil level in the hydraulic reservoirs in accordance with Article 6.03(2), and service pressure of the hydraulic system;
(b)failure of the electrical supply for the steering control;
(c)failure of the electrical supply for the drive units;
(d)failure of the rate-of-turn regulator;
(e)failure of the required buffer devices.