ANNEX IIMINIMUM TECHNICAL REQUIREMENTS APPLICABLE TO VESSELS ON INLAND WATERWAYS OF ZONES 1, 2, 3 AND 4

PART II

CHAPTER 9ELECTRICAL EQUIPMENT

Article 9.03Protection against physical contact, intrusion of solid objects and the ingress of water

The type of minimum protection for permanently installed parts of an installation shall be as set out in the following table:

a

Where appliances release large amounts of heat: IP 12.

b

Where appliances or panels do not have this type of protection their location shall meet the conditions applying to that type of protection.

c

Electrical equipment of the certified safety type as in accordance with

(a)

European standards EN 50014: 1997; 50015: 1998; 50016: 2002; 50017: 1998; 50018: 2000; 50019: 2000 and 50020: 2002;

or

(b)

IEC publication 60079 as of 1 October 2003.

LocationType of minimum protection(in accordance with IEC publ. 60529: 1992)
GeneratorsMotorsTrans-formersPanelsDistributorsSwitchesFittingsLighting equipment
Operation rooms, engine rooms, steering-gear compartmentsIP 22IP 22IPb 22IPa b 22IP 44IP 22
HoldsIP 55IP 55
Battery and paint lockers

IP 44

u. (Ex)c

Free decks and open steering positionsIP 55IP 55IP 55IP 55
WheelhouseIP 22IP 22IP 22IP 22IP 22
Accommodation apart from sanitary facilities and washroomsIP 22IP 20IP 20
Sanitary facilities and washroomsIP 44IP 44IP 44IP 55IP 44