in accommodation and service spaces:
the fire extinguishers shall be so located that no point in the space is more than 10 metres walking distance from an extinguisher;
an extinguisher suitable for use in high voltage areas shall be located in the proximity of any electric panel or subpanel having a power of 20 kW or more;
in galleys the extinguishers shall be so located that no point in the space is more than 10 metres walking distance from an extinguisher;
an extinguisher shall be located in the proximity of paint lockers store rooms containing readily flammable products;
at least one extinguisher shall be located on the navigating bridge and in each control station.
the Administration of the Flag State shall ensure that portable fire extinguishers shall be periodically inspected, function-tested and pressure-tested.”