xmlns:atom="http://www.w3.org/2005/Atom"

ANNEX VIITechnical provisions relating to installations and activities using organic solvents

PART 5Reduction scheme

1.The operator may use any reduction scheme, specially designed for his installation.

2.In the case of applying coatings, varnishes, adhesives or inks, the following scheme can be used. Where the following method is inappropriate, the competent authority may allow an operator to apply any alternative scheme achieving equivalent emission reductions to those achieved if the emission limit values of Parts 2 and 3 were to be applied. The design of the scheme shall take into account the following facts:

(a)

where substitutes containing little or no solvent are still under development, a time extension shall be given to the operator to implement his emission reduction plans;

(b)

the reference point for emission reductions should correspond as closely as possible to the emissions which would have resulted had no reduction action been taken.

3.The following scheme shall operate for installations for which a constant solid content of product can be assumed:

(a)

The annual reference emission is calculated as follows:

(i)

The total mass of solids in the quantity of coating and/or ink, varnish or adhesive consumed in a year is determined. Solids are all materials in coatings, inks, varnishes and adhesives that become solid once the water or the volatile organic compounds are evaporated.

(ii)

The annual reference emissions are calculated by multiplying the mass determined in (i) by the appropriate factor listed in the table below. Competent authorities may adjust these factors for individual installations to reflect documented increased efficiency in the use of solids.

ActivityMultiplication factor for use in item (a)(ii)
Rotogravure printing; flexography printing; laminating as part of a printing activity; varnishing as part of a printing activity; wood coating; coating of textiles, fabric film or paper; adhesive coating4
Coil coating, vehicle refinishing3
Food contact coating, aerospace coatings2,33
Other coatings and rotary screen printing1,5
(b)

The target emission is equal to the annual reference emission multiplied by a percentage equal to:

(i)

(the fugitive emission limit value + 15), for installations falling within item 6 and the lower threshold band of items 8 and 10 of Part 2,

(ii)

(the fugitive emission limit value + 5) for all other installations.

(c)

Compliance is achieved if the actual solvent emission determined from the solvent management plan is less than or equal to the target emission.