a The values quoted in the specification are “true values”. In the establishment of their limit values, the terms of EN ISO 4259:2006 “Petroleum products — Determination and application of precision data in relation to methods of test” have been applied and in fixing a minimum value, a minimum difference of 2R above zero has been taken into account (R = reproducibility). The results of individual measurements shall be interpreted on the basis of the criteria described in EN ISO 4259:2006. | |
Bioethanol content (%v/v) | Vapour pressure waiver permitted (kPa)a |
---|---|
0 | 0 |
1 | 3,7 |
2 | 6,0 |
3 | 7,2 |
4 | 7,8 |
5 | 8,0 |
6 | 8,0 |
7 | 7,9 |
8 | 7,9 |
9 | 7,8 |
10 | 7,8 |
The permitted vapour pressure waiver for intermediate bioethanol content between the values listed shall be determined by a straight line interpolation between the bioethanol content immediately above and that immediately below the intermediate value.”