ANNEX III
Exemption | Scope and dates of applicability | |
---|---|---|
1 | Mercury in single capped (compact) fluorescent lamps not exceeding (per burner): | |
1(a) | For general lighting purposes < 30 W: 5 mg | Expires on 31 December 2011; 3,5 mg may be used per burner after 31 December 2011 until 31 December 2012; 2,5 mg shall be used per burner after 31 December 2012 |
1(b) | For general lighting purposes ≥ 30 W and < 50 W: 5 mg | Expires on 31 December 2011; 3,5 mg may be used per burner after 31 December 2011 |
1(c) | For general lighting purposes ≥ 50 W and < 150 W: 5 mg | |
1(d) | For general lighting purposes ≥ 150 W: 15 mg | |
1(e) | For general lighting purposes with circular or square structural shape and tube diameter ≤ 17 mm | No limitation of use until 31 December 2011; 7 mg may be used per burner after 31 December 2011 |
1(f) | For special purposes: 5 mg | |
F21(g) | For general lighting purposes < 30 W with a lifetime equal or above 20 000 h: 3,5 mg | Expires on 31 December 2017 |
2(a) | Mercury in double-capped linear fluorescent lamps for general lighting purposes not exceeding (per lamp): | |
2(a)(1) | Tri-band phosphor with normal lifetime and a tube diameter < 9 mm (e.g. T2): 5 mg | Expires on 31 December 2011; 4 mg may be used per lamp after 31 December 2011 |
2(a)(2) | Tri-band phosphor with normal lifetime and a tube diameter ≥ 9 mm and ≤ 17 mm (e.g. T5): 5 mg | Expires on 31 December 2011; 3 mg may be used per lamp after 31 December 2011 |
2(a)(3) | Tri-band phosphor with normal lifetime and a tube diameter > 17 mm and ≤ 28 mm (e.g. T8): 5 mg | Expires on 31 December 2011; 3,5 mg may be used per lamp after 31 December 2011 |
2(a)(4) | Tri-band phosphor with normal lifetime and a tube diameter > 28 mm (e.g. T12): 5 mg | Expires on 31 December 2012; 3,5 mg may be used per lamp after 31 December 2012 |
2(a)(5) | Tri-band phosphor with long lifetime (≥ 25 000 h): 8 mg | Expires on 31 December 2011; 5 mg may be used per lamp after 31 December 2011 |
2(b) | Mercury in other fluorescent lamps not exceeding (per lamp): | |
2(b)(1) | Linear halophosphate lamps with tube > 28 mm (e.g. T10 and T12): 10 mg | Expires on 13 April 2012 |
2(b)(2) | Non-linear halophosphate lamps (all diameters): 15 mg | Expires on 13 April 2016 |
2(b)(3) | Non-linear tri-band phosphor lamps with tube diameter > 17 mm (e.g. T9) | No limitation of use until 31 December 2011; 15 mg may be used per lamp after 31 December 2011 |
2(b)(4) | Lamps for other general lighting and special purposes (e.g. induction lamps) | No limitation of use until 31 December 2011; 15 mg may be used per lamp after 31 December 2011 |
3 | Mercury in cold cathode fluorescent lamps and external electrode fluorescent lamps (CCFL and EEFL) for special purposes not exceeding (per lamp): | |
3(a) | Short length (≤ 500 mm) | No limitation of use until 31 December 2011; 3,5 mg may be used per lamp after 31 December 2011 |
3(b) | Medium length (> 500 mm and ≤ 1 500 mm) | No limitation of use until 31 December 2011; 5 mg may be used per lamp after 31 December 2011 |
3(c) | Long length (> 1 500 mm) | No limitation of use until 31 December 2011; 13 mg may be used per lamp after 31 December 2011 |
4(a) | Mercury in other low pressure discharge lamps (per lamp) | No limitation of use until 31 December 2011; 15 mg may be used per lamp after 31 December 2011 |
4(b) | Mercury in High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner) in lamps with improved colour rendering index Ra > 60: | |
4(b)-I | P ≤ 155 W | No limitation of use until 31 December 2011; 30 mg may be used per burner after 31 December 2011 |
4(b)-II | 155 W < P ≤ 405 W | No limitation of use until 31 December 2011; 40 mg may be used per burner after 31 December 2011 |
4(b)-III | P > 405 W | No limitation of use until 31 December 2011; 40 mg may be used per burner after 31 December 2011 |
4(c) | Mercury in other High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner): | |
4(c)-I | P ≤ 155 W | No limitation of use until 31 December 2011; 25 mg may be used per burner after 31 December 2011 |
4(c)-II | 155 W < P ≤ 405 W | No limitation of use until 31 December 2011; 30 mg may be used per burner after 31 December 2011 |
4(c)-III | P > 405 W | No limitation of use until 31 December 2011; 40 mg may be used per burner after 31 December 2011 |
4(d) | Mercury in High Pressure Mercury (vapour) lamps (HPMV) | Expires on 13 April 2015 |
4(e) | Mercury in metal halide lamps (MH) | |
4(f) | Mercury in other discharge lamps for special purposes not specifically mentioned in this Annex | |
F34(g) | Mercury in hand crafted luminous discharge tubes used for signs, decorative or architectural and specialist lighting and light-artwork, where the mercury content shall be limited as follows:
| Expires on 31 December 2018 |
5(a) | Lead in glass of cathode ray tubes | |
5(b) | Lead in glass of fluorescent tubes not exceeding 0,2 % by weight | |
F46(a) | Lead as an alloying element in steel for machining purposes and in galvanised steel containing up to 0,35 % lead by weight | Expires on:
|
6(a)-I | Lead as an alloying element in steel for machining purposes containing up to 0,35 % lead by weight and in batch hot dip galvanised steel components containing up to 0,2 % lead by weight | Expires on 21 July 2021 for categories 1-7 and 10. |
F56(b) | Lead as an alloying element in aluminium containing up to 0,4 % lead by weight | Expires on:
|
6(b)-I | Lead as an alloying element in aluminium containing up to 0,4 % lead by weight, provided it stems from lead-bearing aluminium scrap recycling | Expires on 21 July 2021 for categories 1-7 and 10. |
6(b)-II | Lead as an alloying element in aluminium for machining purposes with a lead content up to 0,4 % by weight | Expires on 18 May 2021 for categories 1-7 and 10. |
F66(c) | Copper alloy containing up to 4 % lead by weight | Expires on:
|
F77(a) | Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead) | Applies to categories 1-7 and 10 (except applications covered by point 24 of this Annex) and expires on 21 July 2021. For categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments expires on 21 July 2021. For category 8 in vitro diagnostic medical devices expires on 21 July 2023. For category 9 industrial monitoring and control instruments, and for category 11 expires on 21 July 2024. |
7(b) | Lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signalling, transmission, and network management for telecommunications | |
F87(c)-I | Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, e.g. piezoelectronic devices, or in a glass or ceramic matrix compound | Applies to categories 1-7 and 10 (except applications covered under point 34) and expires on 21 July 2021. For categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments expires on 21 July 2021. For category 8 in vitro diagnostic medical devices expires on 21 July 2023. For category 9 industrial monitoring and control instruments, and for category 11 expires on 21 July 2024. |
7(c)-II | Lead in dielectric ceramic in capacitors for a rated voltage of 125 V AC or 250 V DC or higher | |
7(c)-III | Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC | Expires on 1 January 2013 and after that date may be used in spare parts for EEE placed on the market before 1 January 2013 |
F97(c)-IV | Lead in PZT based dielectric ceramic materials for capacitors which are part of integrated circuits or discrete semiconductors | Expires on 21 July 2016 |
8(a) | Cadmium and its compounds in one shot pellet type thermal cut-offs | Expires on 1 January 2012 and after that date may be used in spare parts for EEE placed on the market before 1 January 2012 |
8(b) | Cadmium and its compounds in electrical contacts | |
9 | Hexavalent chromium as an anticorrosion agent of the carbon steel cooling system in absorption refrigerators up to 0,75 % by weight in the cooling solution | |
F109(b) | Lead in bearing shells and bushes for refrigerant-containing compressors for heating, ventilation, air conditioning and refrigeration (HVACR) applications | Applies to categories 8, 9 and 11; expires on:
|
9(b)-(I) | Lead in bearing shells and bushes for refrigerant-containing hermetic scroll compressors with a stated electrical power input equal or below 9 kW for heating, ventilation, air conditioning and refrigeration (HVACR) applications | Applies to category 1; expires on 21 July 2019. |
11(a) | Lead used in C-press compliant pin connector systems | May be used in spare parts for EEE placed on the market before 24 September 2010 |
11(b) | Lead used in other than C-press compliant pin connector systems | Expires on 1 January 2013 and after that date may be used in spare parts for EEE placed on the market before 1 January 2013 |
12 | Lead as a coating material for the thermal conduction module C-ring | May be used in spare parts for EEE placed on the market before 24 September 2010 |
F1113(a) | Lead in white glasses used for optical applications | Applies to all categories; expires on:
|
F1213(b) | Cadmium and lead in filter glasses and glasses used for reflectance standards | Applies to categories 8, 9 and 11; expires on:
|
13(b)-(I) | Lead in ion coloured optical filter glass types | Applies to categories 1 to 7 and 10; expires on 21 July 2021 for categories 1 to 7 and 10 |
13(b)-(II) | Cadmium in striking optical filter glass types; excluding applications falling under point 39 of this Annex | |
13(b)-(III) | Cadmium and lead in glazes used for reflectance standards | |
14 | Lead in solders consisting of more than two elements for the connection between the pins and the package of microprocessors with a lead content of more than 80 % and less than 85 % by weight | Expired on 1 January 2011 and after that date may be used in spare parts for EEE placed on the market before 1 January 2011 |
15 | Lead in solders to complete a viable electrical connection between semiconductor die and carrier within integrated circuit flip chip packages | |
16 | Lead in linear incandescent lamps with silicate coated tubes | Expires on 1 September 2013 |
17 | Lead halide as radiant agent in high intensity discharge (HID) lamps used for professional reprography applications | |
18(a) | Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps when used as speciality lamps for diazoprinting reprography, lithography, insect traps, photochemical and curing processes containing phosphors such as SMS ((Sr,Ba)2MgSi2O7:Pb) | Expired on 1 January 2011 |
18(b) | Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps when used as sun tanning lamps containing phosphors such as BSP (BaSi2O5:Pb) | |
19 | Lead with PbBiSn-Hg and PbInSn-Hg in specific compositions as main amalgam and with PbSn-Hg as auxiliary amalgam in very compact energy saving lamps (ESL) | Expires on 1 June 2011 |
20 | Lead oxide in glass used for bonding front and rear substrates of flat fluorescent lamps used for Liquid Crystal Displays (LCDs) | Expires on 1 June 2011 |
21 | Lead and cadmium in printing inks for the application of enamels on glasses, such as borosilicate and soda lime glasses | |
23 | Lead in finishes of fine pitch components other than connectors with a pitch of 0,65 mm and less | May be used in spare parts for EEE placed on the market before 24 September 2010 |
F1324 | Lead in solders for the soldering to machined through hole discoidal and planar array ceramic multilayer capacitors | Expires on:
|
25 | Lead oxide in surface conduction electron emitter displays (SED) used in structural elements, notably in the seal frit and frit ring | |
26 | Lead oxide in the glass envelope of black light blue lamps | Expires on 1 June 2011 |
27 | Lead alloys as solder for transducers used in high-powered (designated to operate for several hours at acoustic power levels of 125 dB SPL and above) loudspeakers | Expired on 24 September 2010 |
29 | Lead bound in crystal glass as defined in Annex I (Categories 1, 2, 3 and 4) of Council Directive 69/493/EEC21 | |
30 | Cadmium alloys as electrical/mechanical solder joints to electrical conductors located directly on the voice coil in transducers used in high-powered loudspeakers with sound pressure levels of 100 dB (A) and more | |
31 | Lead in soldering materials in mercury free flat fluorescent lamps (which, e.g. are used for liquid crystal displays, design or industrial lighting) | |
32 | Lead oxide in seal frit used for making window assemblies for Argon and Krypton laser tubes | |
33 | Lead in solders for the soldering of thin copper wires of 100 μm diameter and less in power transformers | |
F1434 | Lead in cermet-based trimmer potentiometer elements | Applies to all categories; expires on:
|
36 | Mercury used as a cathode sputtering inhibitor in DC plasma displays with a content up to 30 mg per display | Expired on 1 July 2010 |
37 | Lead in the plating layer of high voltage diodes on the basis of a zinc borate glass body | |
38 | Cadmium and cadmium oxide in thick film pastes used on aluminium bonded beryllium oxide | |
F1539(a) | Cadmium selenide in downshifting cadmium-based semiconductor nanocrystal quantum dots for use in display lighting applications (< 0,2 μg Cd per mm2 of display screen area) | X1Expires for all categories on 31 October 2019 |
F1640 | Cadmium in photoresistors for analogue optocouplers applied in professional audio equipment | Expires on 31 December 2013 |
F141 | Lead in solders and termination finishes of electrical and electronic components and finishes of printed circuit boards used in ignition modules and other electrical and electronic engine control systems, which for technical reasons must be mounted directly on or in the crankcase or cylinder of hand-held combustion engines (classes SH:1, SH:2, SH:3 of Directive 97/68/EC of the European Parliament and of the Council22) | Expires on 31 December 2018 |
F1742 | Lead in bearings and bushes of diesel or gaseous fuel powered internal combustion engines applied in non-road professional use equipment:
| Applies to category 11, excluding applications covered by entry 6(c) of this Annex. Expires on 21 July 2024. |
Directive 97/68/EC of the European Parliament and of the Council of 16 December 1997 on the approximation of the laws of the Member States relating to measures against the emission of gaseous and particulate pollutants from internal combustion engines to be installed in non-road mobile machinery (OJ L 59, 27.2.1998, p. 1). |
Substituted by Corrigendum to Commission Delegated Directive (EU) 2017/1975 of 7 August 2017 amending, for the purposes of adapting to scientific and technical progress, Annex III to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for cadmium in colour converting light-emitting diodes (LEDs) for use in display systems (Official Journal of the European Union L 281 of 31 October 2017).