Please note that the date you requested in the address for this web page is not an actual date upon which a change occurred to this item of legislation. You are being shown the legislation from , which is the first date before then upon which a change was made.
Textual Amendments
F1 Substituted by Commission Delegated Directive 2014/9/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead and cadmium in metallic bonds creating superconducting magnetic circuits in MRI, SQUID, NMR (Nuclear Magnetic Resonance) or FTMS (Fourier Transform Mass Spectrometer) detectors (Text with EEA relevance).
Textual Amendments
F2 Inserted by Commission Delegated Directive 2014/2/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for cadmium in phosphor coatings in image intensifiers for X-ray images until 31 December 2019 and in spare parts for X-ray systems placed on the EU market before 1 January 2020 (Text with EEA relevance).
Textual Amendments
F3 Inserted by Commission Delegated Directive 2014/3/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead acetate marker for use in stereotactic head frames for use with CT (Computed Tomography) and MRI and in positioning systems for gamma beam and particle therapy equipment (Text with EEA relevance).
Textual Amendments
F4 Inserted by Commission Delegated Directive 2014/1/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead as an alloying element for bearings and wear surfaces in medical equipment exposed to ionising radiation (Text with EEA relevance).
Textual Amendments
F5 Inserted by Commission Delegated Directive 2014/4/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead enabling vacuum tight connections between aluminium and steel in X-ray image intensifiers (Text with EEA relevance).
Textual Amendments
F6 Inserted by Commission Delegated Directive 2014/6/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in the surface coatings of pin connector systems requiring nonmagnetic connectors which are used durably at a temperature below – 20 °C under normal operating and storage conditions (Text with EEA relevance).
solders on printed circuit boards;
termination coatings of electrical and electronic components and coatings of printed circuit boards;
solders for connecting wires and cables;
solders connecting transducers and sensors.
Lead in solders of electrical connections to temperature measurement sensors in devices which are designed to be used periodically at temperatures below – 150 °C.
These exemptions expire on 30 June 2021 .]
Textual Amendments
F7 Substituted by Commission Delegated Directive (EU) 2016/1028 of 19 April 2016 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in solders of electrical connections to temperature measurement sensors in certain devices (Text with EEA relevance).
solders,
termination coatings of electrical and electronic components and printed circuit boards,
connections of electrical wires, shields and enclosed connectors,
which are used in
magnetic fields within the sphere of 1 m radius around the isocentre of the magnet in medical magnetic resonance imaging equipment, including patient monitors designed to be used within this sphere, or
magnetic fields within 1 m distance from the external surfaces of cyclotron magnets, magnets for beam transport and beam direction control applied for particle therapy.
Expires on 30 June 2020 .]
Textual Amendments
F8 Inserted by Commission Delegated Directive 2014/7/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in solders, termination coatings of electrical and electronic components and printed circuit boards, connections of electrical wires, shields and enclosed connectors which are used (a) in magnetic fields within the sphere of 1 m radius around the isocentre of the magnet in medical magnetic resonance imaging equipment, including patient monitors designed to be used within this sphere, or (b) in magnetic fields within 1 m distance from the external surfaces of cyclotron magnets, magnets for beam transport and beam direction control applied for particle therapy (Text with EEA relevance).
Textual Amendments
F9 Inserted by Commission Delegated Directive 2014/8/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in solders for mounting cadmium telluride and cadmium zinc telluride digital array detectors to printed circuit boards (Text with EEA relevance).
Textual Amendments
F10 Inserted by Commission Delegated Directive 2014/10/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in alloys, as a superconductor or thermal conductor, used in cryo-cooler cold heads and/or in cryo-cooled cold probes and/or in cryo-cooled equipotential bonding systems, in medical devices (category 8) and/or in industrial monitoring and control instruments (Text with EEA relevance).
Textual Amendments
F11 Inserted by Commission Delegated Directive 2014/11/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for hexavalent chromium in alkali dispensers used to create photocathodes in X-ray image intensifiers until 31 December 2019 and in spare parts for X-ray systems placed on the EU market before 1 January 2020 (Text with EEA relevance).
Textual Amendments
F12 Deleted by Commission Delegated Directive (EU) 2016/585 of 12 February 2016 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead, cadmium, hexavalent chromium, and polybrominated diphenyl ethers (PBDE) in spare parts recovered from and used for the repair or refurbishment of medical devices or electron microscopes (Text with EEA relevance).
Expires on:
21 July 2021 for the use in medical devices other than in vitro diagnostic medical devices;
21 July 2023 for the use in in vitro diagnostic medical devices;
21 July 2024 for the use in electron microscopes and their accessories.]
Textual Amendments
F13 Inserted by Commission Delegated Directive (EU) 2016/585 of 12 February 2016 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead, cadmium, hexavalent chromium, and polybrominated diphenyl ethers (PBDE) in spare parts recovered from and used for the repair or refurbishment of medical devices or electron microscopes (Text with EEA relevance).
Textual Amendments
F14 Inserted by Commission Delegated Directive 2014/12/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in solders on printed circuit boards of detectors and data acquisition units for Positron Emission Tomographs which are integrated into Magnetic Resonance Imaging equipment (Text with EEA relevance).
Textual Amendments
F15 Inserted by Commission Delegated Directive 2014/13/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in solders on populated printed circuit boards used in Directive 93/42/EEC class IIa and IIb mobile medical devices other than portable emergency defibrillators (Text with EEA relevance).
Textual Amendments
F16 Inserted by Commission Delegated Directive 2014/16/EU of 18 October 2013 amending, for the purposes of adapting to technical progress, the Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead as an activator in the fluorescent powder of discharge lamps when used for extracorporeal photopheresis lamps containing BSP (BaSi2O5:Pb) phosphors (Text with EEA relevance).
Expires on 21 July 2024 .]
Textual Amendments
F17 Inserted by Commission Delegated Directive 2014/75/EU of 13 March 2014 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for mercury in cold cathode fluorescent lamps (CCFLs) for back-lighting liquid crystal displays, not exceeding 5 mg per lamp, used in industrial monitoring and control instruments placed on the market before 22 July 2017 (Text with EEA relevance).
Expires on 31 December 2020 . May be used after that date in spare parts for industrial monitoring and control instruments placed on the market before 1 January 2021 .]
Textual Amendments
F18 Inserted by Commission Delegated Directive 2014/74/EU of 13 March 2014 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead used in other than C-press compliant pin connector systems for industrial monitoring and control instruments (Text with EEA relevance).
wide-range measurements with a conductivity range covering more than 1 order of magnitude (e.g. range between 0,1 mS/m and 5 mS/m) in laboratory applications for unknown concentrations;
measurements of solutions where an accuracy of +/– 1 % of the sample range and where high corrosion resistance of the electrode are required for any of the following:
solutions with an acidity < pH 1;
solutions with an alkalinity > pH 13;
corrosive solutions containing halogen gas;
measurements of conductivities above 100 mS/m that must be performed with portable instruments.
Expires on 31 December 2018 .]
Textual Amendments
F19 Inserted by Commission Delegated Directive 2014/73/EU of 13 March 2014 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in platinized platinum electrodes used for conductivity measurements (Text with EEA relevance).
Expires on 31 December 2019 . May be used after that date in spare parts for CT and X-ray systems placed on the market before 1 January 2020 .]
Textual Amendments
F20 Inserted by Commission Delegated Directive 2014/71/EU of 13 March 2014 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in solder in one interface of large area stacked die elements (Text with EEA relevance).
a compact size of the detector for electrons or ions, where the space for the detector is limited to a maximum of 3 mm/MCP (detector thickness + space for installation of the MCP), a maximum of 6 mm in total, and an alternative design yielding more space for the detector is scientifically and technically impracticable;
a two-dimensional spatial resolution for detecting electrons or ions, where at least one of the following applies:
a response time shorter than 25 ns;
a sample detection area larger than 149 mm 2 ;
a multiplication factor larger than 1,3 × 10 3 .
a response time shorter than 5 ns for detecting electrons or ions;
a sample detection area larger than 314 mm 2 for detecting electrons or ions;
a multiplication factor larger than 4,0 × 10 7 .
The exemption expires on the following dates:
21 July 2021 for medical devices and monitoring and control instruments;
21 July 2023 for in-vitro diagnostic medical devices;
21 July 2024 for industrial monitoring and control instruments.]
Textual Amendments
F21 Inserted by Commission Delegated Directive 2014/70/EU of 13 March 2014 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in micro-channel plates (MCPs) (Text with EEA relevance).
Expires on 31 December 2020 . May be used after that date in spare parts for industrial monitoring and control instruments placed on the market before 1 January 2021 .]
Textual Amendments
F22 Inserted by Commission Delegated Directive 2014/69/EU of 13 March 2014 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC for industrial monitoring and control instruments (Text with EEA relevance).
Expires on 31 December 2018 .]
Textual Amendments
F23 Inserted by Commission Delegated Directive (EU) 2015/573 of 30 January 2015 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for lead in polyvinyl chloride sensors in in-vitro diagnostic medical devices (Text with EEA relevance).
Expires on 30 June 2019 .]
Textual Amendments
F24 Inserted by Commission Delegated Directive (EU) 2015/574 of 30 January 2015 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for mercury in intravascular ultrasound imaging systems (Text with EEA relevance).
Expires on 15 July 2023 .]
Textual Amendments
F25 Inserted by Commission Delegated Directive (EU) 2016/1029 of 19 April 2016 amending, for the purposes of adapting to technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for cadmium anodes in Hersch cells for certain oxygen sensors used in industrial monitoring and control instruments (Text with EEA relevance).
Applies to category 9. Expires on 31 March 2027 .]
Textual Amendments
F26 Inserted by Commission Delegated Directive (EU) 2020/364 of 17 December 2019 amending, for the purposes of adapting to scientific and technical progress, Annex IV to Directive 2011/65/EU of the European Parliament and of the Council as regards an exemption for the use of cadmium in certain radiation tolerant video camera tubes (Text with EEA relevance).