- Latest available (Revised)
- Point in Time (31/12/2020)
- Original (As adopted by EU)
Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (recast) (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.
The values of the rated operating conditions shall be specified by the manufacturer as follows:
For the temperature of the liquid: θmax, θmin,
for the temperature differences: Δθmax, Δθmin,
subject to the following restrictions: ; Δθmin = 3 K or 5 K or 10 K.
For the pressure of the liquid: The maximum positive internal pressure that the thermal energy meter can withstand permanently at the upper limit of the temperature.
For the flow rates of the liquid: qs, qp, qi, where the values of qp and qi are subject to the following restriction: .
For the thermal power: Ps.
The following accuracy classes are defined for thermal energy meters: 1, 2, 3.
The maximum permissible relative errors applicable to a complete thermal energy meter, expressed in percent of the true value for each accuracy class, are:
For class 1: , with Ef, Et, Ec according to points 7.1 to 7.3.
For class 2: , with Ef, Et, Ec according to points 7.1 to 7.3.
For class 3: , with Ef, Et, Ec according to points 7.1 to 7.3.
The complete thermal energy meter shall not exploit the MPEs or systematically favour any party.
After an appropriate test, taking into account the period of time estimated by the manufacturer, has been performed, the following criteria shall be satisfied:
Flow sensors: The variation of the measurement result after the durability test, when compared with the initial measurement result, shall not exceed the critical change value.
Temperature sensors: The variation of the measurement result after the durability test, when compared with the initial measurement result, shall not exceed 0,1 °C.
Accuracy class
Limits of flow rate
Limits of temperature
Limits of temperature difference
Place of the flow sensor installation: flow or return
Indication of the direction of flow
The provisions for sub-assemblies may apply to sub-assemblies manufactured by the same or different manufacturers. Where a thermal energy meter consists of sub-assemblies, the essential requirements for the thermal energy meter apply to the sub-assemblies as relevant. In addition, the following apply:
where the error Ef relates the indicated value to the true value of the relationship between flow sensor output signal and the mass or the volume.
where the error Et relates the indicated value to the true value of the relationship between temperature sensor pair output and temperature difference.
where the error Ec relates the value of the thermal energy indicated to the true value of the thermal energy.
Flow sensor: | Accuracy class |
Limits of flow rate | |
Limits of temperature | |
Nominal meter factor (e.g. litres/pulse) or corresponding output signal | |
Indication of the direction of flow | |
Temperature sensor pair: | [X1Type identification (e.g. Pt100)] |
Limits of temperature | |
Limits of temperature difference | |
Calculator: | Type of temperature sensors
|
Editorial Information
X1 Substituted by Corrigendum to Directive 2014/32/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments (Official Journal of the European Union L 96 of 29 March 2014).
The Whole Directive you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: