CHAPTER III Area measuring instruments
Operating conditions
1.1. Range
Dimensions within the range specified by the manufacturer for the instrument.
1.2. Condition of the product
The manufacturer shall specify the limitations of the instruments due to the speed, and thickness of the surface conditions if relevant, of the product.
MPEs
2. Instrument
The MPE is 1,0 %, but not less than 1 dm2.
Other requirements
3. Presentation of the product
In the case of pulling back or stopping the product, it shall not be possible to have an error of measurement or the display must be blanked.
4. Scale interval
The instruments must have a scale interval of 1,0 dm2. In addition, it must be possible to have a scale interval of 0,1 dm2 for testing purposes.