Please note that the date you requested in the address for this web page is not an actual date upon which a change occurred to this item of legislation. You are being shown the legislation from , which is the first date before then upon which a change was made.

ANNEX XIU.K.DETERMINATION OF VOLATILE HALOGENATED SOLVENTS CONTENT OF OLIVE OIL

1.METHODU.K.

Analysis by gas chromatography using the head space technique.

2.EQUIPMENTU.K.

2.1.Gas chromatography apparatus fitted with an electron capture detector (ECD).U.K.

2.2.Head space apparatus.U.K.

2.3.Gas chromatography column, of glass, 2 m long and 2 mm in diameter, stationary phase. OV101 10 % or equivalent, impregnating a calcined diatomaceous earth, acid washed and silanised and of a particle size of 80 to 100 mesh.U.K.

2.4.Carrier and auxiliary gas: nitrogen for gas chromatography, suitable for detection by electron capture.U.K.

2.5.Glass flasks, 10 to 15 ml, with teflon coating and aluminium stopper with fitment for entry of syringe.U.K.